Farah Deeba

Farah Deeba

Auto-generated profile, based on publicly available information

Farah Deeba

Department of Electrical and Computer Engineering, University of North Carolina at Charlotte, Charlotte, NC, USA.

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
FDFarah Deeba
Farah Deeba
FBFrancis M. Bui
Francis M. Bui
KWKhan A. Wahid
Khan A. Wahid

26 September 2017 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Closed access
MAMohammad Wajih Alam
Mohammad Wajih Alam
MHMehedi Hasan
Mehedi Hasan
SMShahed Khan Mohammed
Shahed Khan Mohammed
FDFarah Deeba
Farah Deeba
Khan WahidKhan Wahid
Khan Wahid
The recent technological advances in capsule endoscopy system has revolutionized the healthcare system by introducing new techniques and functionalities in the system to diagnose entire gastrointestinal tract which resulted in better diagnostic accuracy, reducing hospitalization, and improving its clinical outcome. Although many benefits of present capsule endoscopy are known, there are still significant drawbacks with respect to conventional endoscope system including size, battery life, bandwidth, image quality and higher frame rate, which has restricted its wide use. In order to solve the problem related to current capsule endoscope, the importance of a low-cost and low-power compression algorithm, that produces higher frame rate with better image quality but lower bandwidth and transmission power, is paramount. While several review papers have been published describing the capability of capsule endoscope in terms of its functionality and emerging features, an extensive review on the compression algorithms from the past and for the future is still required. Hence, in this review paper, we aim to address the issue by exploring the specific characteristics of endoscopic images, summarizing useful compression techniques with in-depth analysis and finally making suggestions for possible future adaptation.

1 December 2021 in Medical Image Analysis
Verified
Journal Article
Open access
FDFarah Deeba
Farah Deeba
CSCaitlin Schneider
Caitlin Schneider
SMShahed Mohammed
Shahed Mohammed
MHMohammad Honarvar
Mohammad Honarvar
JLJulio Lobo
Julio Lobo
RRRobert Rohling
Robert Rohling
Quantitative ultrasound (QUS) offers a non-invasive and objective way to quantify tissue health. We recently presented a spatially adaptive regularization method for reconstruction of a single QUS parameter, limited to a two dimensional region. That proof-of-concept study showed that regularization using homogeneity prior improves the fundamental precision-resolution trade-off in QUS estimation. Based on the weighted regularization scheme, we now present a multiparametric 3D weighted QUS (3D QUS) method, involving the reconstruction of three QUS parameters: attenuation coefficient estimate (ACE), integrated backscatter coefficient (IBC) and effective scatterer diameter (ESD). With the phantom studies, we demonstrate that our proposed method accurately reconstructs QUS parameters, resulting in high reconstruction contrast and therefore improved diagnostic utility. Additionally, the proposed method offers the ability to analyze the spatial distribution of QUS parameters in 3D, which allows for superior tissue characterization. We apply a three-dimensional total variation regularization method for the volumetric QUS reconstruction. The 3D regularization involving N planes results in a high QUS estimation precision, with an improvement of standard deviation over the theoretical 1/N rate achievable by compounding N independent realizations. In the in vivo liver study, we demonstrate the advantage of adopting a multiparametric approach over the single parametric counterpart, where a simple quadratic discriminant classifier using feature combination of three QUS parameters was able to attain a perfect classification performance to distinguish between normal and fatty liver cases.

1 May 2019 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
FDFarah Deeba
Farah Deeba
MMManyou Ma
Manyou Ma
MPMehran Pesteie
Mehran Pesteie
JTJefferson Terry
Jefferson Terry
DPDenise Pugash
Denise Pugash
RRRobert Rohling
Robert Rohling

10 October 2019
Verified
Book Chapter
Closed access
PDF file
FDFarah Deeba
Farah Deeba
CSCaitlin Schneider
Caitlin Schneider
SMShahed Mohammed
Shahed Mohammed
MHMohammad Honarvar
Mohammad Honarvar
ETEdward Tam
Edward Tam
RRRobert Rohling
Robert Rohling

27 September 2022 in Ultrasound in Medicine & Biology
Verified
Journal Article
Open access
FDFarah Deeba
Farah Deeba
RHRicky Hu
Ricky Hu
VLVictoria Lessoway
Victoria Lessoway
JTJefferson Terry
Jefferson Terry
DPDenise Pugash
Denise Pugash
RRRobert Rohling
Robert Rohling
Pregnancy complications such as pre-eclampsia (PE) and intrauterine growth restriction (IUGR) are associated with structural and functional changes in the placenta. Different elastography techniques with an ability to assess the mechanical properties of tissue can identify and monitor the pathological state of the placenta. Currently available elastography techniques have been used with promising results to detect placenta abnormalities; however, limitations include inadequate measurement depth and safety concerns from high negative pressure pulses. Previously, we described a shear wave absolute vibro-elastography (SWAVE) method by applying external low-frequency mechanical vibrations to generate shear waves and studied 61 post-delivery clinically normal placentas to explore the feasibility of SWAVE for placental assessment and establish a measurement baseline. This next phase of the study, namely, SWAVE 2.0, improves the previous system and elasticity reconstruction by incorporating a multi-frequency acquisition system and using a 3-D local frequency estimation (LFE) method. Compared with its 2-D counterpart, the proposed system using 3-D LFE was found to reduce the bias and variance in elasticity measurements in tissue-mimicking phantoms. In the aim of investigating the potential of improved SWAVE 2.0 measurements to identify placental abnormalities, we studied 46 post-delivery placentas, including 26 diseased (16 IUGR and 10 PE) and 20 normal control placentas. By use of a 3.33-MHz motorized curved-array transducer, multi-frequency (80,100 and 120 Hz) elasticity measures were obtained with 3-D LFE, and both IUGR (15.30 ± 2.96 kPa, p = 3.35e-5) and PE (12.33 ± 4.88 kPa, p = 0.017) placentas were found to be significantly stiffer compared with the control placentas (8.32 ± 3.67 kPa). A linear discriminant analysis (LDA) classifier was able to classify between healthy and diseased placentas with a sensitivity, specificity and accuracy of 87%, 78% and 83% and an area under the receiver operating curve of 0.90 (95% confidence interval: 0.8-0.99). Further, the pregnancy outcome in terms of neonatal intensive care unit admission was predicted with a sensitivity, specificity and accuracy of 70%, 71%, 71%, respectively, and area under the receiver operating curve of 0.78 (confidence interval: 0.62-0.93). A viscoelastic characterization of placentas using a fractional rheological model revealed that the viscosity measures in terms of viscosity parameter n were significantly higher in IUGR (2.3 ± 0.21) and PE (2.11 ± 0.52) placentas than in normal placentas (1.45 ± 0.65). This work illustrates the potential relevance of elasticity and viscosity imaging using SWAVE 2.0 as a non-invasive technology for detection of placental abnormalities and the prediction of pregnancy outcomes.