Robert L. Barrack

Robert L. Barrack

Auto-generated profile, based on publicly available information

Robert L. Barrack

Department of Orthopaedic Surgery, Washington University in St. Louis. St. Louis, MO, USA

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2013 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
RBRobert L. Barrack
Robert L. Barrack
JKJeffrey A. Krempec
Jeffrey A. Krempec
JCJohn C. Clohisy
John C. Clohisy
DMDouglas J. McDonald
Douglas J. McDonald
WRWilliam M. Ricci
William M. Ricci
RNRyan M. Nunley
Ryan M. Nunley
Frequency in which acetabular components are placed within a predetermined target range. Methods: We evaluated postoperative anteroposterior pelvic radiographs for every consecutive primary total hip arthroplasty and surface replacement arthroplasty completed from 2004 to 2009 at a single institution. Acetabular component abduction and anteversion angles were determined using Martell Hip Analysis Suite software. We defined target ranges for abduction and anteversion for both total hip arthroplasty (30° to 55° and 5° to 35°, respectively) and surface replacement arthroplasty (30° to 50° and 5° to 25°, respectively). Surgeon and patient-related factors were analyzed for risk associated with placing the acetabular component outside the target range. Results: Of the 1549 total hip arthroplasties, 1435 components (93%) met our abduction target, 1472 (95%) met our anteversion target, and 1363 (88%) simultaneously met both targets. Of the 263 surface replacement arthroplasties, 233 components (89%) met our abduction target, 247 (94%) met our anteversion target, and 220 (84%) simultaneously met both targets. When previously published target ranges of abduction (30° to 45°) and anteversion (5° to 25°) angles were used, only 665 total hip replacements (43%) met the abduction target, 1325 (86%) met the anteversion target, and 584 (38%) simultaneously met both targets. Of the surface replacement arthroplasties, 181 (69%) met the abduction target, 247 (94%) met the anteversion target, and 172 (65%) simultaneously met both targets. Low-volume surgeons were 2.16 times more likely to miss target component position compared with high-volume surgeons (p = 0.002). The odds of missing the target increased by ≥0.2 for every 5 kg/m2 increase in body mass index. Minimally invasive approaches, diagnosis, years of surgical experience, femoral head size, and age of the patient did not affect component position. Conclusions: Increased odds of component malposition were found with lower-volume surgeons and higher body mass index. No other variables had a significant effect on component placement. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence....

1 October 2009 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
PDF file
MSM. Catherine Sargent
M. Catherine Sargent
WSWayne Sotile
Wayne Sotile
MSMary O Sotile
Mary O Sotile
HRHarry Rubash
Harry Rubash
RBRobert L. Barrack
Robert L. Barrack
Background: A pilot study of two academic training programs revealed concerning levels of resident burnout and psychological dysfunction. The purpose of the present study was to determine the quality of life of orthopaedic residents and faculty on a national scale and to identify risk factors for decompensation. Methods: Three hundred and eighty-four orthopaedic residents and 264 full-time orthopaedic faculty members completed a voluntary, anonymous survey consisting of three validated instruments (the Maslach Burnout Inventory, the General Health Questionnaire-12, and the Revised Dyadic Adjustment Scale) and question sets assessing demographic information, relationship issues, stress reactions/management, and work/life balance. Results: High levels of burnout were seen in 56% of the residents and 28% of the faculty members. Burnout risk was greatest among second-postgraduate-year residents and residents in training programs with six or more residents per postgraduate year. Sixteen percent of residents and 19% of faculty members reported symptoms of psychological distress. Sleep deprivation was common among the residents and correlated positively with every distress measure. Faculty reported greater levels of stress but greater satisfaction with work and work/life balance. A number of factors, such as making time for hobbies and limiting alcohol use, correlated with decreased dysfunction for both residents and faculty. Conclusions: Despite reporting high levels of job satisfaction, orthopaedic residents and faculty are at risk for burnout and distress. Identification of protective factors and risk factors may provide guidance to improve the quality of life of academic orthopaedic surgeons in training and beyond.

1 January 2014 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
RBRobert L. Barrack
Robert L. Barrack
ERErin L. Ruh
Erin L. Ruh
JCJiajing Chen
Jiajing Chen
ALAdolph V. Lombardi
Adolph V. Lombardi
KBKeith R. Berend
Keith R. Berend
RNRyan M. Nunley
Ryan M. Nunley
Red to patient socioeconomic status is not known. Questions/purposes We determined whether (1) socioeconomic factors, (2) demographic factors, or (3) implant factors were associated with satisfaction and functional outcomes after TKA in young patients. Methods We surveyed 661 patients (average age, 54 years; range, 18-60 years; 61% female) 1 to 4 years after undergoing modern primary TKA for noninflammatory arthritis at five orthopaedic centers. Data were collected by an independent third party with expertise in collecting healthcare data for state and federal agencies. We examined specific questions regarding satisfaction, pain, and function after TKA and socioeconomic (household income, education, employment) and demographic (sex, minority status) factors. Multivariable analysis was conducted to examine the relative importance of these factors for each outcome of interest. Results Patients reporting incomes of less than USD 25,000 were less likely to be satisfied with TKA outcomes and more likely to have functional limitations after TKA than patients with higher incomes; no other socioeconomic factors were associated with satisfaction. Women were less likely to be satisfied and more likely to have functional limitations than men, and minority patients were more likely to have functional limitations than nonminority patients. Implants were not associated with outcomes after surgery. Conclusions Socioeconomic factors, in particular low income, are more strongly associated with satisfaction and functional outcomes in young patients after TKA than demographic or implant factors. Future studies should be directed to determining the causes of this association, and studies of clinical results after TKA should consider stratifying patients by socioeconomic status. Level of Evidence Level III, therapeutic study. See Instructions for Authors for a complete description of levels of evidence....

3 July 2019 in Journal of Bone and Joint Surgery
Verified
Journal Article
Open access
DNDenis Nam
Denis Nam
CLCharles M. Lawrie
Charles M. Lawrie
RSRondek Salih
Rondek Salih
CNCindy R. Nahhas
Cindy R. Nahhas
RBRobert L. Barrack
Robert L. Barrack
RNRyan M. Nunley
Ryan M. Nunley
Background: Highly porous surfaces promoting biologic fixation have renewed interest in cementless total knee arthroplasty (TKA), but the potential for failed biologic fixation remains. The purpose of this study was to compare the clinical outcomes of cemented and cementless versions of the same TKA design at an average of 2 years postoperatively. Methods: This was an institutional review board-approved, prospective, randomized controlled trial of patients from 18 to 75 years of age who were undergoing a primary TKA. Patients with inflammatory arthritis, a body mass index (BMI) of >40 kg/m2, infection, a neuromuscular disorder, or grossly osteoporotic bone or bone defects were excluded. Patients were randomized to receive a cemented or cementless cruciate-retaining TKA of the same design. The cementless implant has highly porous fixation surfaces. Oxford Knee, Knee Society, and Forgotten Joint Scores were collected. Patients were asked to rate the knee with the TKA as a percentage of normal. Power analysis indicated that 130 patients were necessary to demonstrate a 5-point difference in the Oxford Knee Score at 90% power. Results: One hundred and forty-seven patients were enrolled, and 141 (96%) of them were analyzed at an average of 2 years postoperatively. There was no difference in age, sex, BMI, American Society of Anesthesiologists (ASA) score, or duration of follow-up (p = 0.1 to 0.9). There was also no difference in the change in the hemoglobin level from the preoperative measurement to postoperative day 1 between the 2 cohorts (mean and standard deviation, −2.6 ± 1.4 g/dL compared with −2.5 ± 0.9 g/dL, p = 0.5), but the total operative time was decreased in the cementless cohort (82.1 ± 16.6 compared with 93.7 ± 16.7 minutes, p = 0.001). There were no differences in any clinical outcome measure at 4 to 6 weeks, 1 year, or an average of 2 years postoperatively (p = 0.1 to 0.9) between the cemented and cementless cohorts. There was no radiographic evidence of component subsidence or loosening in either cohort. Conclusions: This study demonstrated that a recently introduced cementless TKA had results, both perioperatively and at an average of 2 years postoperatively, that were equivalent to those of its cemented predecessor, without any aseptic failures of either implant. Thus, this study justifies continued surveillance of this device to elucidate both its survivorship and if it can provide any long-term benefits. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

1 November 2008 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
PDF file
JPJavad Parvizi
Javad Parvizi
EGElie Ghanem
Elie Ghanem
PSPeter Sharkey
Peter Sharkey
AAAjay Aggarwal
Ajay Aggarwal
SBStephen R. J. Burnett
Stephen R. J. Burnett
RBRobert L. Barrack
Robert L. Barrack
Although total knee arthroplasty (TKA) is an effective and successful procedure, the outcome is occasionally compromised by complications including periprosthetic joint infection (PJI). Accurate and early diagnosis is the first step in effectively managing patients with PJI. At the present time, diagnosis remains dependent on clinical judgment and reliance on standard clinical tests including serologic tests, analysis of aspirated joint fluid, and interpretation of intraoperative tissue and fluid test results. Although reports regarding sensitivity and specificity of all diagnostic tests in the literature are abundant, the interpretation of the available data has been hampered by the low sample size of these studies. In view of the scope of this important problem and the limitations of previous reports, a large database was assembled of all revision TKA performed at three academic referral centers in order to determine the current status of diagnosis of the infected TKA utilizing commonly available tests. Intraoperative cultures should not be used as a gold standard for PJI owing to high percentages of false-negative and false-positive cases. When combined with clinical judgment, total white cell count and percentage of neutrophils in the synovial fluid more accurately reflects PJI and when combined with hematologic exams safely excludes or confirms infection. Level of Evidence: Level II, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.

1 November 2012 in The Journal of Bone and Joint Surgery. British volume
Verified
Journal Article
Closed access
PDF file
RBR. L. Barrack
R. L. Barrack
ERE. L. Ruh
E. L. Ruh
BWB. M. Williams
B. M. Williams
AFA. D. Ford
A. D. Ford
KFK. Foreman
K. Foreman
RNR. M. Nunley
R. M. Nunley
Patient specific cutting guides generated by preoperative Magnetic Resonance Imaging (MRI) of the patient’s extremity have been proposed as a method of improving the consistency of Total Knee Arthroplasty (TKA) alignment and adding efficiency to the operative procedure. The cost of this option was evaluated by quantifying the savings from decreased operative time and instrument processing costs compared to the additional cost of the MRI and the guide. Coronal plane alignment was measured in an unselected consecutive series of 200 TKAs, 100 with standard instrumentation and 100 with custom cutting guides. While the cutting guides had significantly lower total operative time and instrument processing time, the estimated $322 savings was overwhelmed by the $1,500 additional cost of the MRI and the cutting guide. All measures of coronal plane alignment were equivalent between the two groups. The data does not currently support the proposition that patient specific guides add value to TKA.