Haoxuan Si

Haoxuan Si

Auto-generated profile, based on publicly available information

Haoxuan Si

MOE Key Laboratory of Advanced Micro-Structure Materials

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2024 in Optics Express
Verified
Journal Article
Closed access
HSHaoxuan Si
Haoxuan Si
Shengzhen YiShengzhen Yi
Shengzhen Yi
TMTingfeng Ming
Tingfeng Ming
ZZZhe Zhang
Zhe Zhang
GLGongshun Li
Gongshun Li
GLGuoqiang Li
Guoqiang Li
A multispectral extreme ultraviolet imaging system based on a separated multichannel Schwarzschild objective was developed for emission measurements of tokamak plasma, with a wide field of view, high spatial resolution, and multispectral resolution. Multiple energy responses were realized by depositing different multilayer coatings on each mirror, targeting the interesting spectral lines of common impurities, such as Ne, C, and W, observed in tokamak experiments. Direct-current magnetron sputtering in conjunction with mask reshaping was employed to fabricate highly uniform multilayers on large-curvature substrates, achieving a thickness control accuracy of ±0.1 nm. Furthermore, this paper proposes an assembly and adjustment scheme that transitions from single-channel centering to multichannel integration, ensuring high-precision alignment across all channels. The design, preparation, and experimental validation of the proposed system are reported. The system was experimentally validated in the Experimental and Advanced Superconducting Tokamak facility, successfully detecting all target spectral lines. The results of the study demonstrate the feasibility of electron temperature measurements using the proposed system.

1 June 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
HXHao Xu
Hao Xu
SWShengyou Wen
Shengyou Wen
HSHaoxuan Si
Haoxuan Si
QHQiushi Huang
Qiushi Huang
ZZZhe Zhang
Zhe Zhang
ZWZhanshan Wang
Zhanshan Wang
Multiple monochromatic x-ray imaging (MMI) is a technique for diagnosing the emission spectra of tracer elements in laser-driven inertial confinement fusion experiments. This study proposes an MMI method that combines a simple pinhole array with a laterally graded multilayer mirror. The method directly obtains multiple monochromatic x-ray images by regulating the multilayer thickness in different mirror positions to compensate for the energy-broadening effect. This paper presents a comprehensive design scheme, the multilayer fabrication and experimental verification of the gradient MMI imaging performance. The experimental results show that the method achieves monochromatic imaging with a spectral resolution of ∼70–90 eV in several keV energy regions. This paper presents a practical diagnostic approach for directly and synchronously capturing the spatial, temporal, and spectral information of laser plasma x rays.

1 July 2024 in AIP Advances
Verified
Journal Article
Open access
PDF file
HDHuiyao Du
Huiyao Du
HSHaoxuan Si
Haoxuan Si
LJLi Jiang
Li Jiang
Shengzhen YiShengzhen Yi
Shengzhen Yi
ZWZhanshan Wang
Zhanshan Wang
JDJiaqin Dong
Jiaqin Dong
Here, we developed a high-resolution, dual-channel toroidal-crystal x-ray imager for time-framed x-ray backlit imaging diagnostics using the 4.727 keV helium-like Ti line. We also presented a method for adjusting the dual-channel imager through the self-imaging of a two-dimensional periodic object. Offline x-ray experiments achieved a spatial resolution of ∼5.0 μm in the center and better than 8.0 μm within a field of view (FOV) of ∼2 mm. At the ShenGuang-III prototype laser facility, we obtained imaging results with a spatial resolution of better than 5 μm within an FOV of ±40 µm. This imager thus provides a way of observing with high spatial, temporal, and spectral resolutions to diagnose the behavior of laser-produced plasma.

20 January 2026 in Optics Express
Verified
Journal Article
Closed access
HXHao Xu
Hao Xu
KDKe Dong
Ke Dong
EZErmeng Zhang
Ermeng Zhang
HDHuiyao Du
Huiyao Du
HSHaoxuan Si
Haoxuan Si
Shengzhen YiShengzhen Yi
Shengzhen Yi
Soft X-ray spectroscopic diagnostics based on Dante spectrometers are essential for evaluating plasma conditions driven by Z-pinch or laser fusion. A Dante spectrometer configuration capable of achieving low spectral measurement uncertainty remains a bottleneck problem at present. This paper develops a quantitative uncertainty-analysis framework for Dante spectrometers employing an array of quasi-monochromatic multilayer mirrors. Accordingly, we further developed a set of practical methods, including the precise synchrotron radiation calibration and optimized spectrometer installation, to effectively suppress these measurement uncertainties. For implementation, we developed a Dante spectrometer covering 100–1000 eV and validated it on a Z-pinch platform. The relative expanded uncertainty of individual channels was maintained within 2%–3%, and the reconstructed spectral-distribution uncertainty was better than 3.2%.

8 January 2025 in Optics Express
Verified
Journal Article
Closed access
HSHaoxuan Si
Haoxuan Si
Shengzhen YiShengzhen Yi
Shengzhen Yi
TMTingfeng Ming
Tingfeng Ming
ZZZhe Zhang
Zhe Zhang
GLGongshun Li
Gongshun Li
GLGuoqiang Li
Guoqiang Li
This erratum corrects the affiliation addresses of authors of our paper [ Opt. Express 32, 43748 (2024).10.1364/OE.545563 ].