María Pilar Giraldo

María Pilar Giraldo

Auto-generated profile, based on publicly available information

María Pilar Giraldo

Forest Science and Technology Centre of Catalonia CTFC, Catalan Institute of Wood INCAFUST, Ctra. Sant Llorenc, Km 2, 25280, Solsona, Spain

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Energy and Buildings
Verified
Journal Article
Open access
MPMariana Palumbo
Mariana Palumbo
ALA.M. Lacasta
A.M. Lacasta
MGM.P. Giraldo
M.P. Giraldo
LHL. Haurie
L. Haurie
ECE. Correal
E. Correal

1 May 2017 in Construction and Building Materials
Verified
Journal Article
Open access
MPM. Palumbo
M. Palumbo
ALAna Maria Maria Lacasta Lacasta
Ana Maria Maria Lacasta Lacasta
Antonia Navarro EzquerraAntonia Navarro Ezquerra
Antonia Navarro Ezquerra
MGM.P. Giraldo
M.P. Giraldo
BLB. Lesar
B. Lesar
In the present paper, the performance of an innovative thermal insulation rigid board is evaluated in terms of fire behaviour and fungal resistance. The board is based on vegetal pith and a natural gum (corn pith and sodium alginate) and it is completely compostable. This new composite was developed in previous work. Here boric acid, aluminium hydroxide and ammonium polyphosphate are used as fire retardants and montan wax, acetic acid and lactic acid are used as water repellent and fungicides respectively. Interactions between these different treatments is investigated. Both flaming and smouldering combustion processes of the different formulations are evaluated by small-scale techniques which include pyrolysis microcalorimetry and thermogravimetric analysis. A medium-scale device is also designed in order to study the impact of the different additives to the smouldering kinetics. Fire behaviour tests show that good improvement is obtained, both in flaming and smouldering combustion when boric acid is added. Although smouldering is not avoided in any case, the addition of 8% of boric acid or aluminium hydroxide slows down the speed of combustion propagation. The effect of the different additives on the moisture content and mould growth at 97% RH and 27 °C is analysed. Under such severe conditions none of the additives is able to prevent mould growth, with the exception of boric acid. None or marginal mould growth was observed on samples containing 8% of boric acid although moisture content was higher than the other cases.Peer ReviewedPreprin

1 July 2019 in Fire Safety Journal
Verified
Journal Article
Open access
Laia HaurieLaia Haurie
Laia Haurie
MGMaría Pilar Giraldo
María Pilar Giraldo
ALAna Maria Maria Lacasta Lacasta
Ana Maria Maria Lacasta Lacasta
JMJoaquín Montón
Joaquín Montón
Rodolphe SonnierRodolphe Sonnier
Rodolphe Sonnier

29 November 2013 in MATEC Web of Conferences
Verified
Journal Article
Open access
PDF file
MGMaría P. Giraldo
María P. Giraldo
ALAna Lacasta
Ana Lacasta
JAJaume Avellaneda
Jaume Avellaneda
CBCamila Burgos
Camila Burgos
Fire spread through the façades is widely recognized as one of the fastest pathways of fire spreading in the buildings. Fire may spread through the façade in different ways depending on the type of façade system and on the elements and materials from which it is constructed. Ventilated façades are multilayer systems whose main feature is the creation of an air chamber of circulating air between the original building wall and the external cladding. The "chimney effect" in the air cavity is a mechanism that improves the façade's thermal behaviour and avoids the appearance of moisture from rain or condensation. However, in a event of fire, it may contribute to the quickest spreading of fire, representing a significant risk to the upper floors of a building. This study deals with some aspects of fire propagation through the ventilated cavity in ventilated façade systems. Also we review the provisions stipulated by the Spanish building code (Código Técnico de la Edificación, CTE) [1] to avoid fire spread outside the building. The results highlight the importance of the use of proper fire barriers to ensure the compartmentalization of the ventilated cavity, as well as the use of non-combustible thermal insulation materials, among others. In addition, based on the results, it might be considered that the measures stipulated by the CTE are insufficient to limit the risks associated with this kind of façades systems. The study has been performed using field models of computational fluid-dynamics. In particular, the Fire Dynamics Simulator (FDS) software has been used to numerically solve the mathematical integration models.

18 January 2016 in Applications of Structural Fire Engineering
Verified
Journal Article
Open access
PDF file
EPElsa Pastor
Elsa Pastor
BCBeatriu Corberó
Beatriu Corberó
OROriol Rios
Oriol Rios
MGMaría Pilar Giraldo
María Pilar Giraldo
Laia HaurieLaia Haurie
Laia Haurie
EPEulalia Planas
Eulalia Planas
Fire safety community is currently concerned about the response of some widely used insulating materials in case of fire, due to the fact that existing regulations do not show how these materials behave in real conditions, which in some applications may be indeed critical. Within this context, several institutions have recently carried out large-scale tests with the aim of testing such insulator’s contribution to fire growth. In this paper we present a set of large scale tests of compartment and façade fires involving materials and configurations of different nature. Our experiments provided evidence that mineral wool insulator preserves its properties in case of fire, whilst other polymeric-type insulators contribute to fire growth in conditions close to the ones present in real fires.