13 February 2020 in IEEE Transactions on Industrial Electronics
The efficiency of the linear induction machine (LIM) is considerably low due to the large air-gap length and the additional losses resulting from the end-effects. However, so far, a little concentration has been done to increase the efficiency of this kind of motor. Therefore, the main objectives of this paper are to eliminate the weighting factor, reduce the calculation steps and increase the efficiency of the LIM aiding with a proposed finite-set model predictive direct flux control (FS-MPDFC), depending upon the maximum thrust per ampere (MTPA) strategy. The proposed FS-MPDFC is only based on the primary flux-linkage with the help of a novel cost function that does not require any weighting factors in order to considerably reduce the calculation steps. Moreover, the proposed FS-MPDFC is better than the model predictive current control in reducing the calculation step and decreasing the dependence on the transformation matrix and the machine parameters. In order to illustrate the effectiveness of the proposed MTPA based FS-MPDFC, a comparison between the FS-MPDFC, with and without MTPA, and the previously suggested control techniques is presented and discussed. Moreover, a test bench platform of two 3 kW arc induction machines (AIMs) is constructed to emulate the drive performance of the actual LIM. Comprehensive simulation and experiments have fully demonstrated that the proposed FS-MPDFC with MTPA has lower calculation step, lower thrust ripple by 7% and lower primary flux-linkage ripple by 0.4 % compared to those of the FS-MPDTC. Moreover, the efficiency-based FS-MPDFC with MTPA is increased by 4% compared to that of the FS-MPDFC without MTPA.
9 April 2019 in IEEE Transactions on Vehicular Technology
This paper proposes a finite set model predictive control (FS-MPC) based thrust maximization technique for linear induction machines used in linear metros. For modeling of the proposed control method, the end effect is taken into consideration. The proposed control method is used to achieve maximum thrust per ampere and to reduce the thrust ripples. It differs from the FS-MPC methods, where the cost function consists of the thrust and angle errors. The thrust error is calculated from the difference between the reference thrust and the predicted thrust, and the angle error is calculated from the difference between the angle of predicted primary current and the angle of the predicted secondary flux in one side and π /4 on the other side. A comparison between the proposed method and the finite set model predictive direct thrust control (FS-MPDTC) is presented to illustrate the superiority of the proposed method. Both simulation and experimental analysis are conducted to validate the effectiveness of the proposed finite set model predictive direct angle control (FS-MPDAC). A prototype test platform is developed in the laboratory with two 3 kW arc induction motors. The simulation model, experimental test platform, and test results are presented in this paper.
18 September 2020 in IEEE Transactions on Power Electronics
In order to achieve faster speed tracking ability with lower thrust ripple for the linear induction machine (LIM), one robust speed control strategy using sliding mode direct thrust control (SM-DTC) is firstly proposed based on the space vector modulation (SVM) technique with the secondary flux-linkage orientation. Then, one improved maximum thrust per ampere (MTPA) technique is presented to further minimize the primary current and copper loss under the constant output thrust. Full comparison has been made among the proposed SM-DTC, the conventional direct thrust control (DTC) and field orientation control (FOC) methods in different typical working states. Comprehensive simulation and experiments have been done on the basis of two 3 kw arc induction machines (as one demonstration prototype for the real LIM), which adequately confirm that the proposed method can successfully get faster dynamic response with lower thrust ripple.
30 January 2013 in Electric Power Components and Systems
This article presents a simple control strategy to improve the performance of a synchronous reluctance motor drive system fed by a photovoltaic source. The photovoltaic generator parameters are selected based on maintaining the system operating point at the maximum output power of the photovoltaic generator at an average insolation level of 0.5 kW/m2. The proposed control strategy has three main functions; ensuring successful motor starting, maintaining the motor voltage within a permissible range, and forcing the photovoltaic array to operate at the maximum power point possible. Two modes of operation are studied for the proposed system depending upon the level of insolation compared with a critical value, which is the level below which the synchronous reluctance motor cannot work synchronously under the given pumping load. A sample of simulation results is introduced to confirm the effectiveness of the suggested strategy. It has been found that, using the proposed control strategy, the pump flow rate has been increased compared with an uncontrolled system.
3 June 2020 in IEEE Transactions on Energy Conversion
The aim of this paper is to investigate the sensorless voltage control schemes for the wound-rotor BDFIG in both the stand-alone and grid-connected systems. For sensorless target, a new rotor position observer using the space vector flux relations is suggested. The proposed sensorless algorithm does not require any additional observers for obtaining the generator speed by directly detecting the rotor position, which may reduce the overall system cost. For the voltage control purpose, a DVC scheme is applied for the stand-alone systems. However, this control strategy did not handle the control of the generated-voltage phase angle and also did not consider the phase sequence issue which are very essential provisions for the smooth connection target in grid-connected applications. Hence, DVC strategy cannot guarantee all the intended provisions for a soft and smooth connection process with the grid side and therefore, an effective grid-synchronization algorithm is proposed. A comprehensive analysis to confirm the functionality of the proposed control strategies is discussed through both simulation and experimental results. The presented study in this paper verifies the efficacy of the proposed schemes for sensorless voltage control target of BDFIG in both the stand-alone and grid-connected applications with a good transient behavior.
1 December 2012 in Ain Shams Engineering Journal
This paper presents the performance analysis of a photovoltaic (PV) energy source driving a synchronous reluctance (SyncRel) motor. The design considerations of the PV array, suitable for driving a centrifugal pump, are studied. Three design approaches are proposed at an average insolation of 0.5kW/m2. These approaches depend upon determining the system operating point firstly and then maintaining this point on the PV generator characteristics. The first approach takes motor starting current into account as an additional design criterion. The second one is based on achieving the maximum power at the system operating point. The third approach considers maintaining voltage regulation of the PV generator at a pre-specified suitable value. A sample of the simulation results is introduced using the SyncRel motor measured parameters and the estimated parameters of the PV array. It has been found that the minimum number of cells can be achieved using the second approach