We propose a multimodal biosensor for use in continuous blood pressure (BP) monitoring system. Our proposed novel configuration measures photo-plethysmography (PPG) and impedance plethysmography (IPG) signals simultaneously from the subject wrist. The proposed biosensor system enables a fully non-intrusive system that is cuff-less, also utilize a single measurement site for maximum wearability and convenience of the patients. The efficacy of the proposed technique was evaluated on 10 young healthy subjects. Experimental results indicate that the pulse transit time (PTT)-based features calculated from an IPG peak and PPG maximum second derivative (f14) had a relatively high correlation coefficient (r) to the reference BP, with −0.81 ± 0.08 and −0.78 ± 0.09 for systolic BP (SBP) and diastolic BP (DBP), respectively. Moreover, here we proposed two BP estimation models that utilize six- and one-point calibration models. The six-point model is based on the PTT, whereas the one-point model is based on the combined PTT and radial impedance (Z). Thus, in both models, we observed an adequate root-mean-square-error estimation performance, with 4.20 ± 1.66 and 2.90 ± 0.90 for SBP and DBP, respectively, with the PTT BP model; and 6.86 ± 1.65 and 6.67 ± 1.75 for SBP and DBP, respectively, with the PTT-Z BP model. This study suggests the possibility of estimating a subject’s BP from only wrist bio-signals. Thus, the six- and one-point PTT-Z calibration models offer adequate performance for practical applications.
High data transmission rates are desirable in an optical camera communication (OCC) system. In order to achieve this, a novel multilevel-intensity modulation (m-IM) scheme for a rolling-shutter (RS)-based OCC is introduced in this letter. The proposed multilevel intensity signal is obtained by transmitting the signal pulse time faster than the camera shutter speed, where the shutter speed is highly dependent on the camera exposure time and the RS-effect of CMOS-image sensor of the camera. In addition, pulse width modulation is also used on the transmitter side to control the output intensity (signal pulse) of the LED transmitter. As the optical signal is received wirelessly by the camera, we further propose a novel smartphone-based digital demodulation algorithm for our RS-based OCC system. In this letter, we compare the performance of the proposed system to a typical modulation scheme for OCC system, such as ON-OFF keying. Moreover, an intensive performance test is conducted for different symbol times to determine their relationship to bit error rate and achieved data rate. A data transmission rate >10 kbps over a range of up to 2 m by using a 30 fps smartphone camera can be achieved by using our proposed 4-IM in our proposed scheme.
In this study, a novel high-precision positioning algorithm was proposed by using Visible Light Communication (VLC) with only a simple and single receiver. The received voltage-level difference with multi-level modulation was adopted as the input variable, in order to minimize the negative consequences of noise. Then, the relationship between the received voltage-level difference, noise, and position was developed based on the optical propagation model. The minimum mean squares error algorithm and extended-Kalman filter was employed in order to improve the accuracy of the optical model and achieve high performance. Using the developed algorithm, high-accuracy results with a 0.9 cm average position error in the simulation and 2.56 cm average position error in the practical experiments were obtained.
The state-of-the-art systems for blood pressure (BP) monitoring often use cuffed-based rigid sensory systems, bulky electronics, multiple measurement sites, and intermittent measurement. Here, we introduce a new type of epidermal electronics that were specifically designed for cuffless BP-monitoring system, named multiPANI. The proposed fully integrated wearable device is equipped with a wireless-flexible hybrid electronics, a personalized flexible sensor array, and encapsulated with a thin biocompatible elastomer layer for soft-conformal contact with the complex skin surface structure. In addition, a unique capability of multiPANI to monitor multiple local pulse wave velocity (PWV) enabling us to develop a novel hybrid BP estimation algorithm that combine a selective-local PWV and high-signal-to-noise-ratio-based pulse wave analysis (PWA) for robust-cuffless BP-monitoring system. Experimental results indicate that the proposed hybrid selective PWV-PWA BP model outperform the typical single-PWV BP model by ~30%, with an acceptable root-mean-square-error performance of 3.94 ± 0.5 and 1.88 ± 0.9 mmHg, for systolic BP and diastolic BP respectively. Collectively, this study demonstrated a unique solution of fully integrated epidermal electronics and hybrid BP estimation algorithm for a robust, cuffless, and long-term BP monitoring.
Soft strain sensors pose great potential for emerging human–machine interfaces. However, their real-world applications have been limited due to challenges such as low reproducibility, susceptibility to environmental noise, and short lifetimes, which are attributed to nanotechnologies, including microfabrication techniques. In this study, we present a computer vision-based optical strain (CVOS) sensor system that integrates computer vision with streamlined microfabrication techniques to overcome these challenges and facilitate real-time multiaxial strain mapping. The proposed CVOS sensor consists of an easily fabricated soft silicone substrate with micro-markers and a tiny camera for highly sensitive marker detection. Real-time multiaxial strain mapping allows for measuring and distinguishing complex multi-directional strain patterns, providing the proposed CVOS sensor with higher scalability. Our results indicate that the proposed CVOS sensor is a promising approach for the development of highly sensitive and versatile human–machine interfaces that can operate long-term under real-world conditions.