Vega Pradana Rachim

Vega Pradana Rachim

Auto-generated profile, based on publicly available information

Vega Pradana Rachim

Department of Convergence IT Engineering, Pohang University of Science and Technology (POSTECH), Pohang, South Korea

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
VRVega Pradana Rachim
Vega Pradana Rachim
Wan-Young ChungWan-Young Chung
Wan-Young Chung

28 May 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
VRVega Pradana Rachim
Vega Pradana Rachim
Wan-Young ChungWan-Young Chung
Wan-Young Chung
We propose a multimodal biosensor for use in continuous blood pressure (BP) monitoring system. Our proposed novel configuration measures photo-plethysmography (PPG) and impedance plethysmography (IPG) signals simultaneously from the subject wrist. The proposed biosensor system enables a fully non-intrusive system that is cuff-less, also utilize a single measurement site for maximum wearability and convenience of the patients. The efficacy of the proposed technique was evaluated on 10 young healthy subjects. Experimental results indicate that the pulse transit time (PTT)-based features calculated from an IPG peak and PPG maximum second derivative (f14) had a relatively high correlation coefficient (r) to the reference BP, with −0.81 ± 0.08 and −0.78 ± 0.09 for systolic BP (SBP) and diastolic BP (DBP), respectively. Moreover, here we proposed two BP estimation models that utilize six- and one-point calibration models. The six-point model is based on the PTT, whereas the one-point model is based on the combined PTT and radial impedance (Z). Thus, in both models, we observed an adequate root-mean-square-error estimation performance, with 4.20 ± 1.66 and 2.90 ± 0.90 for SBP and DBP, respectively, with the PTT BP model; and 6.86 ± 1.65 and 6.67 ± 1.75 for SBP and DBP, respectively, with the PTT-Z BP model. This study suggests the possibility of estimating a subject’s BP from only wrist bio-signals. Thus, the six- and one-point PTT-Z calibration models offer adequate performance for practical applications.

6 April 2018 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
VRVega Pradana Rachim
Vega Pradana Rachim
Wan-Young ChungWan-Young Chung
Wan-Young Chung
High data transmission rates are desirable in an optical camera communication (OCC) system. In order to achieve this, a novel multilevel-intensity modulation (m-IM) scheme for a rolling-shutter (RS)-based OCC is introduced in this letter. The proposed multilevel intensity signal is obtained by transmitting the signal pulse time faster than the camera shutter speed, where the shutter speed is highly dependent on the camera exposure time and the RS-effect of CMOS-image sensor of the camera. In addition, pulse width modulation is also used on the transmitter side to control the output intensity (signal pulse) of the LED transmitter. As the optical signal is received wirelessly by the camera, we further propose a novel smartphone-based digital demodulation algorithm for our RS-based OCC system. In this letter, we compare the performance of the proposed system to a typical modulation scheme for OCC system, such as ON-OFF keying. Moreover, an intensive performance test is conducted for different symbol times to determine their relationship to bit error rate and achieved data rate. A data transmission rate >10 kbps over a range of up to 2 m by using a 30 fps smartphone camera can be achieved by using our proposed 4-IM in our proposed scheme.

28 February 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
NPNgoc Quan Pham
Ngoc Quan Pham
VRVega Pradana Rachim
Vega Pradana Rachim
Wan-Young ChungWan-Young Chung
Wan-Young Chung
In this study, a novel high-precision positioning algorithm was proposed by using Visible Light Communication (VLC) with only a simple and single receiver. The received voltage-level difference with multi-level modulation was adopted as the input variable, in order to minimize the negative consequences of noise. Then, the relationship between the received voltage-level difference, noise, and position was developed based on the optical propagation model. The minimum mean squares error algorithm and extended-Kalman filter was employed in order to improve the accuracy of the optical model and achieve high performance. Using the developed algorithm, high-accuracy results with a 0.9 cm average position error in the simulation and 2.56 cm average position error in the practical experiments were obtained.

16 February 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
VRVega Pradana Rachim
Vega Pradana Rachim
SKSehong Kang
Sehong Kang
JBJin-Hyeok Baek
Jin-Hyeok Baek
Sung-Min ParkSung-Min Park
Sung-Min Park
The state-of-the-art systems for blood pressure (BP) monitoring often use cuffed-based rigid sensory systems, bulky electronics, multiple measurement sites, and intermittent measurement. Here, we introduce a new type of epidermal electronics that were specifically designed for cuffless BP-monitoring system, named multiPANI. The proposed fully integrated wearable device is equipped with a wireless-flexible hybrid electronics, a personalized flexible sensor array, and encapsulated with a thin biocompatible elastomer layer for soft-conformal contact with the complex skin surface structure. In addition, a unique capability of multiPANI to monitor multiple local pulse wave velocity (PWV) enabling us to develop a novel hybrid BP estimation algorithm that combine a selective-local PWV and high-signal-to-noise-ratio-based pulse wave analysis (PWA) for robust-cuffless BP-monitoring system. Experimental results indicate that the proposed hybrid selective PWV-PWA BP model outperform the typical single-PWV BP model by ~30%, with an acceptable root-mean-square-error performance of 3.94 ± 0.5 and 1.88 ± 0.9 mmHg, for systolic BP and diastolic BP respectively. Collectively, this study demonstrated a unique solution of fully integrated epidermal electronics and hybrid BP estimation algorithm for a robust, cuffless, and long-term BP monitoring.

10 July 2023 in npj Flexible Electronics
Verified
Journal Article
Open access
PDF file
SHSungUk Hong
SungUk Hong
VRVega Pradana Rachim
Vega Pradana Rachim
JBJin-Hyeok Baek
Jin-Hyeok Baek
Sung-Min ParkSung-Min Park
Sung-Min Park
Soft strain sensors pose great potential for emerging human–machine interfaces. However, their real-world applications have been limited due to challenges such as low reproducibility, susceptibility to environmental noise, and short lifetimes, which are attributed to nanotechnologies, including microfabrication techniques. In this study, we present a computer vision-based optical strain (CVOS) sensor system that integrates computer vision with streamlined microfabrication techniques to overcome these challenges and facilitate real-time multiaxial strain mapping. The proposed CVOS sensor consists of an easily fabricated soft silicone substrate with micro-markers and a tiny camera for highly sensitive marker detection. Real-time multiaxial strain mapping allows for measuring and distinguishing complex multi-directional strain patterns, providing the proposed CVOS sensor with higher scalability. Our results indicate that the proposed CVOS sensor is a promising approach for the development of highly sensitive and versatile human–machine interfaces that can operate long-term under real-world conditions.