14 August 2019 in Advances in Structural Engineering
A novel type of prefabricated steel-truss waffle slab has been proposed in this article, and compared with traditional waffle slab, there are several typical characteristics of this floor system, including welded steel wire mesh laid in top concrete wythe, orthogonal steel trusses used to reinforce concrete ribs, and foamed concrete blocks filled among the ribs with the purpose of heat insulation and fire resistance. A special template system is adopted for the installation and concrete cast of prefabricated steel-truss waffle slab. All steel segments in prefabricated steel-truss waffle slab are precast and then assembled to form steel system in site. In order to investigate the structural behavior of prefabricated steel-truss waffle slab, two full-scale specimens with different aspect ratio have been experimentally studied under flexural load. The results obtained from the tests have been discussed and analyzed in the context of ultimate flexural load, cracking pattern and failure mode, load–deflection relationship, and load–strain relationship. The experimental results showed that the ultimate load-bearing capacity of prefabricated steel-truss waffle slab has greatly been influenced by the punching shear failure at the rib joints. Three crack types, such as flexural cracks, tensile cracks, and interface cracks, have been exhibited in the final failure of prefabricated steel-truss waffle slab. The deflection development at slab center has presented a four-stage behavior. The significant effect of aspect ratio has also been verified by strain analysis. A computer program has been developed according to the modified structural design method proposed in this article, and the comparison indicated a good agreement between experimental data and theoretical results.
8 May 2020 in KSCE Journal of Civil Engineering
In order to investigate the static and cyclic tension behavior of post-installed rebar along with cement-based adhesive that is adopted after exposure to high temperature, a three-phase experimental program has been carried out and two typical embedment depths, 10d and 15d are designed. The surfaces of specimens are firstly heated up to 800°C, and then the residual strength at different temperatures of cement-based adhesive has been studied by consequent static pull-out tests. Experimental results show that the tensile strength has a significant reduction at elevated temperatures compared with that of room temperature. The cement-based adhesive has almost lost its full bond strength when the temperature exceeds 350°C. Finally, the bond performance of cement-based adhesive under cyclic loading has been further tested and analyzed. It is found that both 10d and 15d specimens have failed abruptly with rebar pull-out. The employment of long embedment depth has been verified to be an effective method to improve the bond performance of cement-based adhesive under static and cyclic loading. Static numerical investigation indicates that the bond stress distribution is not uniform along the embedment length of post-installed rebar at different temperatures of cement-based adhesive. The temperature-dependent tensile strength prediction has also been obtained based on the experimental data.