Anthony Dávila Álvarez

Anthony Dávila Álvarez

Auto-generated profile, based on publicly available information

Anthony Dávila Álvarez

University of Florida 1 , Gainesville, Florida 32611, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2022 in Journal of Geodesy
Verified
Journal Article
Open access
PDF file
AÁAnthony Dávila Álvarez
Anthony Dávila Álvarez
AKAaron Knudtson
Aaron Knudtson
UPUnmil Patel
Unmil Patel
JGJoseph Gleason
Joseph Gleason
HHHarold Hollis
Harold Hollis
JCJohn W. Conklin
John W. Conklin
A simplified gravitational reference sensor (S-GRS) is an ultra-precise inertial sensor for future Earth geodesy missions. These sensors measure or compensate for all non-gravitational accelerations of the host spacecraft to remove them in the data analysis and recover spacecraft motion due to Earth’s gravity field. Low–low satellite-to-satellite tracking missions like GRACE-FO that use laser ranging interferometers (LRI) are limited by the acceleration noise performance of their electrostatic accelerometers and temporal aliasing associated with Earth’s gravity field. The current accelerometers, used in the GRACE missions, have a limited sensitivity of \(\sim \,10^{-10}\) m/s\(^{2}\)/Hz\(^{1/2}\) around 1 mHz. The S-GRS is estimated to be at least 40 times more sensitive than the GRACE accelerometers and over 500 times more sensitive if operated on a drag-compensated platform. This improvement is enabled by increasing the mass of the sensor’s test mass, increasing the gap between the test mass and its electrode housing, removing the grounding wire used in GRACE, and replacing it with a UV LED-based charge management system. This allows future missions to take advantage of the sensitivity of the GRACE-FO LRI in the gravity recovery analysis. The S-GRS concept is a simplified version of the flight-proven LISA Pathfinder (LPF) GRS. Performance estimates are based on models vetted during the LPF flight and the expected spacecraft environment based on GRACE-FO data. The relatively low volume (\(\sim \,10^4\) cm\(^3\)), mass (\(\sim \) 13 kg), and power (\(\sim \) 20 W) enable the use of S-GRS on microsatellites, reducing launch costs and allowing more satellite pairs to improve the temporal resolution of gravity field maps. The S-GRS design and analysis, as well as its gravity recovery performance in two candidate mission architectures, are discussed in this article.

1 May 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
SAStephen Apple
Stephen Apple
AÁAnthony Dávila Álvarez
Anthony Dávila Álvarez
SKSamantha Parry Kenyon
Samantha Parry Kenyon
ACAndrew Chilton
Andrew Chilton
DKDerek Klein
Derek Klein
JCJohn W. Conklin
John W. Conklin
In this paper, we present the design and performance of the upgraded University of Florida torsion pendulum facility for testing inertial sensor technology related to space-based gravitational wave observatories and geodesy missions. In particular, much work has been conducted on inertial sensor technology related to the Laser Interferometer Space Antenna (LISA) space gravitational wave observatory mission. A significant upgrade to the facility was the incorporation of a newly designed and fabricated LISA-like gravitational reference sensor (GRS) based on the LISA Pathfinder GRS. Its LISA-like geometry has allowed us to make noise measurements that are more representative of those in LISA and has allowed for the characterization of the mechanisms of noise induced on a LISA GRS and their underlying physics. Noise performance results and experiments exploring the effect of temperature gradients across the sensor will also be discussed. The LISA-like sensor also includes unique UV light injection geometries for UV LED based charge management. Pulsed and DC charge management experiments have been conducted using the University of Florida charge management group’s technology readiness level 4 charge management device. These experiments have allowed for the testing of charge management system hardware and techniques as well as characterizations of the dynamics of GRS test mass charging. The work presented here demonstrates the upgraded torsion pendulum’s ability to act as an effective testbed for GRS technology.