Jannik Dippel

Jannik Dippel

Auto-generated profile, based on publicly available information

Jannik Dippel

Sartorius Stedim Biotech GmbH

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Separation and Purification Technology
Verified
Journal Article
Closed access
EVEirini Velali
Eirini Velali
JDJannik Dippel
Jannik Dippel
BSBirgit Stute
Birgit Stute
SHSebastian Handt
Sebastian Handt
TLThomas Loewe
Thomas Loewe
ELEric von Lieres
Eric von Lieres

22 August 2024 in Journal of Cleaner Production
Verified
Journal Article
Open access
MBMAGALI BARBAROUX
MAGALI BARBAROUX
ARAlena Rosskamp
Alena Rosskamp
JDJannik Dippel
Jannik Dippel
ARAlison Rees-Manley
Alison Rees-Manley
BGBernd Garska
Bernd Garska
RTRoberta Tosato
Roberta Tosato

16 July 2020 in PDA Journal of Pharmaceutical Science and Technology
Verified
Journal Article
Closed access
PDF file
DJDippel Jannik
Dippel Jannik
HSHandt Sebastian
Handt Sebastian
HBHansmann Björn
Hansmann Björn
LTLoewe Thomas
Loewe Thomas
Scalability of filter throughput in normal flow filtration runs is an important consideration in the development of biopharmaceutical downstream processes. Depending on the filtration mode used, filter device geometry can significantly affect scalability. In this study, scaling of different PES sterilizing- grade filters was performed in two filtration modes − at constant flow and at constant pressure − using a particulate model solution, as well as a cell-free mAb solution as a representative example. Both filtration methods are compared regarding their practicability as well as their scalability of the final filter throughput and the filtration time. Pressure-dependent filter fouling that occurred with the mAb solution and the model solution showed that using different pressures for small- and process-scale filtration runs could potentially influence the predicted filter capacity. Overall, good scalability of the final filter throughput was determined for filters ranging from small-scale flat disc filters (4.5 cm2) to large pleated filter assemblies (5.4 m2) in filtration runs at constant flow as well as for filter capsules (0.6 m2) of up to 10″ for filtration runs at constant pressure. Moreover, at constant flow, the filtration time can be accurately predicted since it is determined by the adjusted flow rate. However, at constant pressure, potential resistances in process-scale devices can result in lower fluid fluxes and, hence, a longer unpredictable filtration time compared with small-scale filter elements. This paper introduces a novel scaling method performed at constant pressure that compensates for the pressure losses resulting from process-scale device resistances. Improved scalability regarding final filter throughput and filtration time are shown here with this scaling method compared with scaling at constant pressure. Therefore, this study provides information essential in decision-making to achieve optimal scaling within biopharmaceutical process development.