Harald Kuhn

Harald Kuhn

Auto-generated profile, based on publicly available information

Harald Kuhn

Fraunhofer Institute for Electronic Nano Systems

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Katja MeinelKatja Meinel
Katja Meinel
MMMarcel Melzer
Marcel Melzer
CSChris Stoeckel
Chris Stoeckel
Alexey ShaporinAlexey Shaporin
Alexey Shaporin
RFRoman Forke
Roman Forke
HKHarald Kuhn
Harald Kuhn
A 2D scanning micromirror with piezoelectric thin film aluminum nitride (AlN), separately used as actuator and sensor material, is presented. For endoscopic applications, such as fluorescence microscopy, the devices have a mirror plate diameter of 0.7 mm with a 4 mm2 chip footprint. After an initial design optimization procedure, two micromirror designs were realized. Different spring parameters for x- and y-tilt were chosen to generate spiral (Design 1) or Lissajous (Design 2) scan patterns. An additional layout, with integrated tilt angle sensors, was introduced (Design 1-S) to enable a closed-loop control. The micromirror devices were monolithically fabricated in 150 mm silicon-on-insulator (SOI) technology. Si (111) was used as the device silicon layer to support a high C-axis oriented growth of AlN. The fabricated micromirror devices were characterized in terms of their scanning and sensor characteristics in air. A scan angle of 91.2° was reached for Design 1 at 13 834 Hz and 50 V. For Design 2 a scan angle of 92.4° at 12 060 Hz, and 123.9° at 13 145 Hz, was reached at 50 V for the x- and y-axis, respectively. The desired 2D scan patterns were successfully generated. A sensor angle sensitivity of 1.9 pC/° was achieved.

1 December 2022 in Polymers
Verified
Journal Article
Open access
PDF file
FSFranz Selbmann
Franz Selbmann
CSChristina Scherf
Christina Scherf
JLJörn Langenickel
Jörn Langenickel
FRFrank Roscher
Frank Roscher
MWMaik Wiemer
Maik Wiemer
YJYvonne Joseph
Yvonne Joseph
The polymer Parylene combines a variety of excellent properties and, hence, is an object of intensive research for packaging applications, such as the direct encapsulation of medical implants. Moreover, in the past years, an increasing interest for establishing new applications for Parylene is observed. These include the usage of Parylene as a flexible substrate, a dielectric, or a material for MEMS, e.g., a bonding adhesive. The increasing importance of Parylene raises questions regarding the long-term reliability and aging of Parylene as well as the impact of the aging on the Parylene properties. Within this paper, we present the first investigations on non-accelerated Parylene C aging for a period of about five years. Doing so, free-standing Parylene membranes were fabricated to investigate the barrier properties, the chemical stability, as well as the optical properties of Parylene in dependence on different post-treatments to the polymer. These properties were found to be excellent and with only a minor age-related impact. Additionally, the mechanical properties, i.e., the Young’s modulus and the hardness, were investigated via nano-indentation over the same period of time. For both mechanical properties only, minor changes were observed. The results prove that Parylene C is a highly reliable polymer for applications that needs a high long-term stability.

15 April 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
CSChris Stoeckel
Chris Stoeckel
Katja MeinelKatja Meinel
Katja Meinel
MMMarcel Melzer
Marcel Melzer
Agne ZukauskaiteAgne Zukauskaite
Agne Zukauskaite
SZSven Zimmermann
Sven Zimmermann
HKHarald Kuhn
Harald Kuhn
Piezoelectric micromirrors with aluminum nitride (AlN) and aluminum scandium nitride (Al0.68Sc0.32N) are presented and compared regarding their static deflection. Two chip designs with 2 × 3 mm2 (Design 1) and 4 × 6 mm2 (Design 2) footprint with 600 nm AlN or 2000 nm Al0.68Sc0.32N as piezoelectric transducer material are investigated. The chip with Design 1 and Al0.68Sc0.32N has a resonance frequency of 1.8 kHz and a static scan angle of 38.4° at 400 V DC was measured. Design 2 has its resonance at 2.1 kHz. The maximum static scan angle is 55.6° at 220 V DC, which is the maximum deflection measurable with the experimental setup. The static deflection per electric field is increased by a factor of 10, due to the optimization of the design and the research and development of high-performance piezoelectric transducer materials with large piezoelectric coefficient and high electrical breakthrough voltage.

12 August 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
Christian HofmannChristian Hofmann
Christian Hofmann
MSMaulik Satwara
Maulik Satwara
MKMartin Kroll
Martin Kroll
SPSushant Panhale
Sushant Panhale
PRPatrick Rochala
Patrick Rochala
HKHarald Kuhn
Harald Kuhn
Considering the demand for low temperature bonding in 3D integration and packaging of microelectronic or micromechanical components, this paper presents the development and application of an innovative inductive heating system using micro coils for rapid Cu-Sn solid-liquid interdiffusion (SLID) bonding at chip-level. The design and optimization of the micro coil as well as the analysis of the heating process were carried out by means of finite element method (FEM). The micro coil is a composite material of an aluminum nitride (AlN) carrier substrate and embedded metallic coil conductors. The conductive coil geometry is generated by electroplating of 500 µm thick copper into the AlN carrier. By using the aforementioned micro coil for inductive Cu-Sn SLID bonding, a complete transformation into the thermodynamic stable ε-phase Cu3Sn with an average shear strength of 45.1 N/mm2 could be achieved in 130 s by applying a bond pressure of 3 MPa. In comparison to conventional bonding methods using conduction-based global heating, the presented inductive bonding approach is characterized by combining very high heating rates of about 180 K/s as well as localized heating and efficient cooling of the bond structures. In future, the technology will open new opportunities in the field of wafer-level bonding.

8 December 2025 in Journal of Intelligent Manufacturing
Verified
Journal Article
Open access
PDF file
MBMorten Breidung
Morten Breidung
TRTom Rothe
Tom Rothe
ALAndre Lauff
Andre Lauff
PTPeter Thieme
Peter Thieme
JLJan Langer
Jan Langer
HKHarald Kuhn
Harald Kuhn
Chemical mechanical planarization is an integral part of semiconductor industry. It provides wafersurface smoothing at the nanometer scale and is highly monitored. In a typical industrial fabrication facility, millions of data points are generated annually for process control, fault detection and classification purposes. By leveraging this sensor and process data for the training of machine learning models, a foundation for virtual metrology can be established. Utilizing real-world data from a high-mix, high-volume fab, we developed robust and application-oriented machine learning models capable of predicting non-uniformity and spatially resolved material removal rates on wafer surfaces. Experimental results demonstrate the accuracy of these predictions, with a high degree of precision in estimating spatially resolved material removal rates. Furthermore, the analysis of the feature importance via Shapley Additive Explanations of the models reveals that polishing time and carrier rotation are among the most critical factors influencing MRR variability.

16 October 2024 in Energies
Verified
Journal Article
Open access
PDF file
MHMichael Hauck
Michael Hauck
CBChristopher Bickmann
Christopher Bickmann
AMAnnika Morgenstern
Annika Morgenstern
NNNicolas Nagel
Nicolas Nagel
CMChristoph R. Meinecke
Christoph R. Meinecke
SSStefan Streif
Stefan Streif
The measurement of hydrogen concentration in fuel cell systems is an important prerequisite for the development of a control strategy to enhance system performance, reduce purge losses and minimize fuel cell aging effects. In this perspective paper, the working principles of hydrogen sensors are analyzed and their requirements for hydrogen control in fuel cell systems are critically discussed. The wide measurement range, absence of oxygen, high humidity and limited space turn out to be most limiting. A perspective on the development of hydrogen sensors based on palladium as a gas-sensitive metal and based on the organic magnetic field effect in organic light-emitting devices is presented. The design of a test chamber, where the sensor response can easily be analyzed under fuel cell-like conditions is proposed. This allows the generation of practical knowledge for further sensor development. The presented sensors could be integrated into the end plate to measure the hydrogen concentration at the anode in- and outlet. Further miniaturization is necessary to integrate them into the flow field of the fuel cell to avoid fuel starvation in each single cell. Compressed sensing methods are used for more efficient data analysis. By using a dynamical sensor model, control algorithms are applied with high frequency to control the hydrogen concentration, the purge process, and the recirculation pump.