Katja Meinel

Ms. Katja Meinel

Chemnitz University of Technology
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Katja MeinelKatja Meinel
Katja Meinel
MMMarcel Melzer
Marcel Melzer
CSChris Stoeckel
Chris Stoeckel
Alexey ShaporinAlexey Shaporin
Alexey Shaporin
RFRoman Forke
Roman Forke
HKHarald Kuhn
Harald Kuhn
A 2D scanning micromirror with piezoelectric thin film aluminum nitride (AlN), separately used as actuator and sensor material, is presented. For endoscopic applications, such as fluorescence microscopy, the devices have a mirror plate diameter of 0.7 mm with a 4 mm2 chip footprint. After an initial design optimization procedure, two micromirror designs were realized. Different spring parameters for x- and y-tilt were chosen to generate spiral (Design 1) or Lissajous (Design 2) scan patterns. An additional layout, with integrated tilt angle sensors, was introduced (Design 1-S) to enable a closed-loop control. The micromirror devices were monolithically fabricated in 150 mm silicon-on-insulator (SOI) technology. Si (111) was used as the device silicon layer to support a high C-axis oriented growth of AlN. The fabricated micromirror devices were characterized in terms of their scanning and sensor characteristics in air. A scan angle of 91.2° was reached for Design 1 at 13 834 Hz and 50 V. For Design 2 a scan angle of 92.4° at 12 060 Hz, and 123.9° at 13 145 Hz, was reached at 50 V for the x- and y-axis, respectively. The desired 2D scan patterns were successfully generated. A sensor angle sensitivity of 1.9 pC/° was achieved.

26 May 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Katja MeinelKatja Meinel
Katja Meinel
CSChris Stoeckel
Chris Stoeckel
MMMarcel Melzer
Marcel Melzer
SZSven Zimmermann
Sven Zimmermann
RFRoman Forke
Roman Forke
TOThomas Otto
Thomas Otto
A micromirror with piezoelectric thin film aluminum nitride (AlN) as transducer material for actuation and detection is presented. Four sensor elements are integrated for closed-loop monitoring of the resonant driven microscanner with an entire footprint of 6 mm2. The sensor and actuator elements are monolithically fabricated in 150 mm SOI technology. The micromirror is characterized in terms of its scanning and sensor characteristics. A large optical scan angle of 137.90 (34.50 mechanical tilt angle corresponding) at 3385 Hz and 20 V actuation voltage is achieved. The median resonant voltage sensitivity is 4.7 0/V. For the sensor characterization, a cross-talk compensation is introduced, which significantly improves the signal quality and thus enables an accurate charge determination. The sensor signal increases linearly to the deflection. A dynamic sensor angle sensitivity of 48.4 fC/0 is reached. Possible applications of the micromirror are consumer electronics, such as LIDAR or medical applications, such as fluorescence microscopy.

1 June 2019
Verified
Conference Paper
Closed access
Katja MeinelKatja Meinel
Katja Meinel
CSChris Stoeckel
Chris Stoeckel
MMMarcel Melzer
Marcel Melzer
SZSven Zimmermann
Sven Zimmermann
RFRoman Forke
Roman Forke
TOThomas Otto
Thomas Otto
In this paper micromirrors based on piezoelectric thin film aluminum nitride (AlN) are presented. The microsystems with a 6 mm² footprint are fabricated successfully in 150 mm SOI technology. A large tilt angle is achieved by FEM-based optimization of the lever arm parameters. Three micromirror types with varied spring widths are characterized, achieving tilt angles up to 51.3° at 1.9 kHz, 31.6° at 4.6 kHz, and 16.5° at 12.5 kHz for an actuation voltage of less than 5 V. For higher actuation voltages up to 20 V, a maximum scan angle of 104.9° is reached, limited by the measurement setup.

15 April 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
CSChris Stoeckel
Chris Stoeckel
Katja MeinelKatja Meinel
Katja Meinel
MMMarcel Melzer
Marcel Melzer
Agne ZukauskaiteAgne Zukauskaite
Agne Zukauskaite
SZSven Zimmermann
Sven Zimmermann
HKHarald Kuhn
Harald Kuhn
Piezoelectric micromirrors with aluminum nitride (AlN) and aluminum scandium nitride (Al0.68Sc0.32N) are presented and compared regarding their static deflection. Two chip designs with 2 × 3 mm2 (Design 1) and 4 × 6 mm2 (Design 2) footprint with 600 nm AlN or 2000 nm Al0.68Sc0.32N as piezoelectric transducer material are investigated. The chip with Design 1 and Al0.68Sc0.32N has a resonance frequency of 1.8 kHz and a static scan angle of 38.4° at 400 V DC was measured. Design 2 has its resonance at 2.1 kHz. The maximum static scan angle is 55.6° at 220 V DC, which is the maximum deflection measurable with the experimental setup. The static deflection per electric field is increased by a factor of 10, due to the optimization of the design and the research and development of high-performance piezoelectric transducer materials with large piezoelectric coefficient and high electrical breakthrough voltage.

1 October 2019
Verified
Conference Paper
Closed access
Katja MeinelKatja Meinel
Katja Meinel
CSChris Stoeckel
Chris Stoeckel
MMMarcel Melzer
Marcel Melzer
SZSven Zimmermann
Sven Zimmermann
RFRoman Forke
Roman Forke
TOThomas Otto
Thomas Otto
A micromirror with piezoelectric thin film aluminum nitride (AlN) as transducer material for actuation and detection is presented. Four sensor elements are integrated for closed-loop monitoring of the resonant driven microscanner with an entire footprint of 6 mm². The sensor and actuator elements are monolithically fabricated in 150 mm SOI technology. A large optical scan angle of 78.1° at 3.403 kHz and 10 V actuation voltage is achieved. The sensor signal increases linearly to the deflection. A dynamic angle sensitivity of 48.4 fC/° is reached. Possible applications are consumer electronics, such as LIDAR or medical applications, such as fluorescence microscopy.

4 December 2024 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Open access
PDF file
MMM. Melzer
M. Melzer
Katja MeinelKatja Meinel
Katja Meinel
CSChris Stoeckel
Chris Stoeckel
THT. Hemke
T. Hemke
TMThomas Mussenbrock
Thomas Mussenbrock
SZS. Zimmermann
S. Zimmermann
In recent years, micro-electromechanical systems (MEMSs) have found broad applications in various sensors. However, aside from quartz crystal microbalances, they have not yet been utilized in plasma analysis. Building on previous work with piezoelectric MEMS, the functionality of a MEMS-based sensor system capable of measuring the ion angular distribution function on the wafer holder surface is demonstrated. To enable this functionality, an array of high aspect ratio holes was added to the tiltable silicon plate of a piezoelectric MEMS. These holes allow for the filtering of incoming ions based on their angle perpendicular to the surface of the tiltable element. An algorithm was developed to fit the width and mean of the ion angular distribution function (IADF) based on the RMS ion current for various MEMS amplitudes. Compared to previously used methods for measuring the IADF, the MEMS presented in this paper represents a significant miniaturization. This work is the first to successfully characterize the angular distribution function of ions using a MEMS.