Jenna-Leigh Wilson

Jenna-Leigh Wilson

Auto-generated profile, based on publicly available information

Jenna-Leigh Wilson

Department of Orthopaedic Surgery, Washington University School of Medicine, Saint Louis, USA

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2025 in Injury
Verified
Journal Article
Open access
Daniel Enrique PereiraDaniel Enrique Pereira
Daniel Enrique Pereira
Sri TummalaSri Tummala
Sri Tummala
MMMehul M. Mittal
Mehul M. Mittal
MOMitchel Obey
Mitchel Obey
MBMarschall B. Berkes
Marschall B. Berkes
JWJenna L. Wilson
Jenna L. Wilson
Glucagon-like peptide-1 receptor agonists (GLP-1 RAs) are increasingly prescribed for Type 2 diabetes and obesity due to their cardiometabolic benefits. However, their effects on fracture healing remain controversial. This study investigates perioperative GLP-1 RA use and outcomes following surgical treatment of lower extremity (LE) fractures. A retrospective analysis utilizing a large multicenter database compared patients on GLP-1 RAs within one year prior to and after lower extremity index surgery (+GLP) with those not on GLP-1 RAs (-GLP). Propensity score matching was performed on 275,970 included patients, matching 1:1 on age, sex, tobacco use, diabetes mellitus, primary hypertension, hyperlipidemia, chronic ischemic heart disease, chronic lower respiratory disease, and body mass index (BMI), resulting in 6125 "best-matched" patients per group. This was conducted utilizing multivariate logistic regression with a 0.1 caliper. Outcomes were assessed at 1 month, 3 months, and 1 year. At 1-year follow-up, GLP-1 RA users demonstrated a significantly higher rate of nonunion compared to matched controls (5.4% vs 4.4%, Risk Ratio 1.2, 95% CI 1.0-1.4, P < 0.05) when assessing patients who also continued GLP-1 RAs postoperatively. There were no significant differences in wound dehiscence, deep or superficial surgical site infections, or hematoma. Importantly, the +GLP group experienced significantly lower rates of cardiac arrest (0.8% vs 1.6%, RR 0.5, 95% CI 0.3-0.7, P < 0.01) and all-cause mortality (4.4% vs 8.0%, RR 0.5, 95% CI 0.4-0.6, P < 0.01). Perioperative GLP-1 RA use was associated with a higher risk of nonunion following lower extremity fracture surgery, though without increased wound complication rates. Importantly, GLP-1 RA use was linked to reduced cardiac arrest and mortality within one year. These findings suggest that while the increased rate of nonunion is statistically significant, its clinically significance is limited. Thus, the mortality reduction may be more clinically meaningful for patient counseling and perioperative management. Further study is required to clarify the balance between systemic benefits and surgical outcomes of GLP-1 RAs in orthopedic trauma.

7 October 2026 in Journal of Orthopaedic Trauma
Verified
Journal Article
Closed access
DPDaniel E. Pereira
Daniel E. Pereira
SCSundeep Chakladar
Sundeep Chakladar
NHNoah J. Harrison
Noah J. Harrison
BRBrian D. Rust
Brian D. Rust
MOMitchel R. Obey
Mitchel R. Obey
JWJenna L. Wilson
Jenna L. Wilson
Objectives: To evaluate whether a machine learning-based system can accurately measure coronal knee alignment parameters from routine postoperative radiographs following surgical fixation of distal femur fractures. Methods: Design : Retrospective cohort study. Setting: Single-center academic orthopedic trauma practice. Patient Selection Criteria: Adult patients 50 years of age or older who underwent surgical fixation of low-energy OTA/AO 33A and 33C distal femur fractures (including periprosthetic fractures) between November 2020 and December 2024 were retrospectively identified. Outcome Measures and Comparisons: A machine learning-based automated alignment assessment system was trained to identify standard radiographic landmarks, including the femoral intercondylar notch, femoral condyles, tibial spines, and tibial plateaus, and automatically calculate commonly used coronal alignment parameters including joint line convergence angle (JLCA), anatomic femorotibial angle (aFTA), anatomic lateral distal femoral angle (aLDFA), and anatomic medial proximal tibial angle (aMPTA). Automated measurements were compared with manual measurements annotated by a trained observer and validated by an orthopedic surgeon. Results: A total of 287 postoperative AP knee and distal femur radiographs were obtained as part of routine postoperative care and randomly divided into training and testing datasets for model development and validation. The cohort was 78.0% female with a mean age of 72.3 years (range: 50 to 97 years). Automated measurements demonstrated strong agreement with surgeon-validated measurements. Mean absolute error was 1.1° for JLCA (range: 0.0° to 3.5°), 1.5° for aFTA (range: 0.0° to 4.4°), 1.0° for aLDFA (range: 0.0° to 3.1°), and 2.3° for aMPTA (range: 0.1 to 6.4°). Pearson correlation coefficients ranged from 0.4 to 1.0, and Bland-Altman analysis demonstrated minimal systematic bias, with 95% of differences falling within a clinically acceptable range of ±5°. Conclusions: Automated alignment assessment utilizing a machine learning-based system using routine postoperative radiographs provided accurate measurements in distal femur fracture patients and may serve as a practical adjunct for longitudinal surveillance in orthopedic trauma practice. Level of Evidence: Level III

17 March 2026 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Open access
PDF file
BRBrian D. Rust
Brian D. Rust
Daniel Enrique PereiraDaniel Enrique Pereira
Daniel Enrique Pereira
DBDavid W. Barton
David W. Barton
MOMitchel R. Obey
Mitchel R. Obey
CMChristopher M. McAndrew
Christopher M. McAndrew
JWJenna-Leigh Wilson
Jenna-Leigh Wilson
Purpose: Body mass index (BMI) is a recognized risk factor for infection in distal femur fracture management, but the role of local subcutaneous fat thickness at incision sites remains unclear. This study evaluated whether local adiposity independently predicts surgical site infection (SSI) after open reduction internal fixation (ORIF) and compared its predictive value to BMI. Methods: We conducted a retrospective case–control study of 302 adults who underwent ORIF for distal femur fractures at a Level 1 trauma center (2021–2024). Subcutaneous fat depth was measured at lateral, prepatellar, and, when available, medial sites on plain radiographs. The primary outcome was SSI requiring irrigation and debridement within 1 year. Logistic regression assessed the predictive value of fat thickness and BMI, with subgroup analysis of periprosthetic fractures. Results: Nineteen patients (6.3%) developed SSI. On univariate analysis, greater lateral, prepatellar, medial fat, and BMI were significantly associated with infection. Logistic regression showed lateral and prepatellar fat predicted SSI, but these effects were lost once BMI was included, confirming BMI as the stronger independent predictor. In the periprosthetic subgroup, neither BMI nor adiposity predicted infection. Conclusion: In distal femur fractures, BMI outperformed local fat thickness as a predictor of SSI, supporting its use as a practical risk stratification tool. While greater local adiposity correlated with reoperation, these associations diminished when BMI was considered. In periprosthetic fractures, no predictors were identified, highlighting the need for larger studies to clarify whether implants alter infection risk.

19 February 2026 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Open access
PDF file
MOMitchel Obey
Mitchel Obey
BRBrian Rust
Brian Rust
DBDavid Barton
David Barton
JWJenna-Leigh Wilson
Jenna-Leigh Wilson
MBMarschall Berkes
Marschall Berkes
CMChristopher McAndrew
Christopher McAndrew
Surgical treatment of unicondylar distal femur fractures remains a challenge. Achieving stable fixation to allow early range of motion and weightbearing is complicated by poor bone quality and articular surface comminution, commonly leading to poor outcomes. Multiple treatment strategies have been previously described including small fragment, large fragment, and anatomical plate fixation. However, given the variability of fracture patterns, anatomical implants often lack the appropriate geometry and fixation options required to provide adequate stabilization. With knowledge and application of the principles of fracture fixation, these injuries can be effectively treated with standard non-anatomically shaped, contourable implants. The objective of this report was to describe a technique that provides effective fixation in these cases and report on outcomes of a small series. This technique utilizes a dual-implant construct that includes a small or large fragment plate positioned to buttress the metaphyseal apex of the fracture, and a small fragment reconstruction plate contoured in the shape of a “J” (J-plate) that wraps around the femoral condyle and onto the anterior cortex of the femur. There are advantages to this technique compared to anatomically contoured plates, including precise placement of implants in biomechanically advantageous locations, orthogonal fixation, and decreased implant costs.

1 November 2026 in Journal of Orthopaedic Trauma
Verified
Journal Article
Closed access
Daniel Enrique PereiraDaniel Enrique Pereira
Daniel Enrique Pereira
BRBrian Rust
Brian Rust
DBDavid Barton
David Barton
ZEZachary Eggebrecht
Zachary Eggebrecht
JWJenna-Leigh Wilson
Jenna-Leigh Wilson
MBMarschall B. Berkes
Marschall B. Berkes
OBJECTIVES: To compare ambulatory status, union, mortality, and operative complications in patients with distal femur fracture treated with the nail plate combination (NPC) and alternative fixation constructs. METHODS: . Design: Retrospective Cohort Study. Setting: Single Level 1, tertiary referral Academic center Patient Selection Criteria: This study included adults with a low-energy distal femur fracture (OTA/AO33A/C and Su 1–3) that received ORIF within 2018–2024. Exclusions were pathologic fractures, antegrade intramedullary devices, and baseline nonambulators (from ambulatory status evaluation only). Outcome Measures and Comparisons: The primary outcome was ambulatory status at postoperative intervals using Koval-Walking-Score. Secondary outcomes included radiographic union, mortality, and reoperation. RESULTS: A total of 404 patients with a low-energy distal femur fracture were included, with 342 included for mobility analysis. Fixation constructs included 189 NPC (mean age 75.0 ± 10.2, 83.1% female), 118 lateral locking plate (LLP) (mean age 73.4 ± 10.2; 76.3% female), 79 retrograde intramedullary nail (rIMN) (mean age 73.7 ± 11.1, 74.7% female), and 18 dual plate combination (mean age 74.6 ± 10.9, 83.3% female) (age P = 0.567, sex P = 0.701). NPC was more frequently selected for Su 2 (56.2%) and Su 3 (65.9%) ( P = 0.001). NPC demonstrated lower average ambulatory impairment score over LLP: 3 weeks (−0.8; P = 0.002), 6 weeks (−1.1; P < 0.001), and both LLP and rIMN at 3 months (−0.9/−0.8; P = 0.049/0.013) and 6 months (−0.9/−0.8; P = 0.043/0.021). After Bonferroni correction to account for multiple testing, post hoc pairwise comparisons showed that NPC ambulation scores remained lower at 3 and 6 weeks (−0.8, P = 0.024; −1.1, P < 0.001). Six-month mortality was lower in NPC than rIMN (9% vs. 19%; P = 0.04). Dual plate combination showed higher infection (22.2%; P = 0.012), wound dehiscence (11.1%; P = 0.013), and drainage (5.6%; P < 0.001); although sample size limited analysis. Radiographic union was comparable (36.3% vs. 52.9% vs. 39.6% vs. 54.5%, P = 0.104). CONCLUSIONS: In this study, NPC was associated with superior ambulatory recovery rates to preinjury status over single-implant constructs and improved mortality rates over rIMN. Thus, NPC represented a reliable construct for early ambulation and recovery in these injuries. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

1 November 2026 in Journal of Orthopaedic Trauma
Verified
Journal Article
Closed access
HBHelena F Barber
Helena F Barber
Daniel Enrique PereiraDaniel Enrique Pereira
Daniel Enrique Pereira
BRBrian D. Rust
Brian D. Rust
JPJulia M. Perugini
Julia M. Perugini
CRCarrie N. Reaver
Carrie N. Reaver
MBMarschall B. Berkes
Marschall B. Berkes
OBJECTIVES: To characterize injury patterns, treatment differences, and clinical outcomes associated with ballistic and blunt forearm fractures. METHODS: Design: Retrospective cohort study. Setting: Single Level 1 tertiary trauma center, 2018-2023. Patient Selection Criteria: The study included adults (≥18) who underwent operative fixation of diaphyseal radius and/or ulna fractures. Exclusion criteria were ipsilateral intraarticular or unstable elbow injuries, pathologic fractures, or fractures involving preexisting implants. Patients were stratified into 2 groups: ballistic and blunt injuries, which were further subclassified as blunt-closed or blunt-open. Outcome Measures and Comparisons: Primary outcomes included nerve deficit, complication rate, unplanned reoperation, nonunion, and postoperative infection. RESULTS: The study included 395 patients with 398 forearm fractures: 81 ballistic fractures in 78 patients [32 years (18–69), 88.9% male], 213 blunt-closed fractures [41 years (18–82), 59.2% male], and 104 blunt-open fractures [46 years (19–92), 71.2% male]. Ballistic fractures had significantly higher rates of nerve deficits (48.2% vs. 6.3%, P < 0.001), complications (38.5% vs. 21.1%, P = 0.020), and unplanned reoperation (30.8% vs. 14.2%, P = 0.012) compared with blunt injuries. Infection rates were similar between ballistic and blunt groups (10.3% vs. 5.8%, P = 0.294). Nonunion differed only between ballistic and blunt-closed fractures (18.0% vs. 5.6%, P = 0.042), not blunt-open fractures (18.0% vs. 9.2%, P = 0.228). On multivariable analysis, injury group remained an independent predictor of nerve deficit ( P < 0.001), complication ( P = 0.008), and unplanned reoperation ( P = 0.015), with ballistic injuries demonstrating the highest rates. CONCLUSIONS: Ballistic forearm fractures posed unique challenges compared with blunt injuries. They were associated with significantly higher rates of nerve deficit, unplanned reoperations, and overall complications, with higher nonunion observed when compared with blunt-closed injuries. These injuries warrant a high index of suspicion for nerve injury and close long-term follow-up to optimize patient outcomes and address the needs of a disproportionately affected, high-risk population. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.