Department of Mechanical Engineering, Brigham Young University

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2012 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
CDC R Dillon
C R Dillon
UVU Vyas
U Vyas
APA Payne
A Payne
DCD A Christensen
D A Christensen
RRR B Roemer
R B Roemer
Accurate determination of the specific absorption rates (SARs) present during high intensity focused ultrasound (HIFU) experiments and treatments provides a solid physical basis for scientific comparison of results among HIFU studies and is necessary to validate and improve SAR predictive software, which will improve patient treatment planning, control and evaluation. This study develops and tests an analytical solution that significantly improves the accuracy of SAR values obtained from HIFU temperature data. SAR estimates are obtained by fitting the analytical temperature solution for a one-dimensional radial Gaussian heating pattern to the temperature versus time data following a step in applied power and evaluating the initial slope of the analytical solution. The analytical method is evaluated in multiple parametric simulations for which it consistently (except at high perfusions) yields maximum errors of less than 10% at the center of the focal zone compared with errors up to 90% and 55% for the commonly used linear method and an exponential method, respectively. For high perfusion, an extension of the analytical method estimates SAR with less than 10% error. The analytical method is validated experimentally by showing that the temperature elevations predicted using the analytical method's SAR values determined for the entire 3D focal region agree well with the experimental temperature elevations in a HIFU-heated tissue-mimicking phantom.

1 November 2016 in Journal of Controlled Release
Verified
Journal Article
Closed access
NFNick Frazier
Nick Frazier
APAllison Payne
Allison Payne
JBJoshua de Bever
Joshua de Bever
CDChristopher Dillon
Christopher Dillon
APApoorva Panda
Apoorva Panda
HGHamidreza Ghandehari
Hamidreza Ghandehari

1 January 2013 in Journal of Therapeutic Ultrasound
Verified
Journal Article
Open access
PDF file
NRNatalya Rapoport
Natalya Rapoport
APAllison Payne
Allison Payne
CDChristopher Dillon
Christopher Dillon
JSJill Shea
Jill Shea
CSCourtney Scaife
Courtney Scaife
RGRoohi Gupta
Roohi Gupta
Many aspects of the mechanisms involved in ultrasound-mediated therapy remain obscure. In particular, the relative roles of drug and ultrasound, the effect of the time of ultrasound application, and the effect of tissue heating are not yet clear. The current study was undertaken with the goal to clarify these aspects of the ultrasound-mediated drug delivery mechanism.

23 February 2016 in Medical Physics
Verified
Journal Article
Closed access
PDF file
AFAlexis I. Farrer
Alexis I. Farrer
SAScott Almquist
Scott Almquist
CDChristopher R. Dillon
Christopher R. Dillon
LNLeigh A. Neumayer
Leigh A. Neumayer
DPDennis L. Parker
Dennis L. Parker
APAllison Payne
Allison Payne

1 April 2017 in Nanomedicine: Nanotechnology, Biology and Medicine
Verified
Journal Article
Closed access
NFNick Frazier
Nick Frazier
APAllison Payne
Allison Payne
CDChristopher Dillon
Christopher Dillon
NSNithya Subrahmanyam
Nithya Subrahmanyam
HGHamidreza Ghandehari
Hamidreza Ghandehari

8 September 2014 in International Journal of Hyperthermia
Verified
Journal Article
Closed access
PDF file
CDChristopher R. Dillon
Christopher R. Dillon
APAllison Payne
Allison Payne
DCDouglas A. Christensen
Douglas A. Christensen
RRRobert B. Roemer
Robert B. Roemer
Purpose: The use of correct tissue thermal diffusivity values is necessary for making accurate thermal modelling predictions during magnetic resonance-guided focused ultrasound (MRgFUS) treatment planning. This study evaluates the accuracy and precision of two non-invasive thermal diffusivity estimation methods, a Gaussian temperature method and a Gaussian specific absorption rate (SAR) method. Materials and methods: Both methods utilise MRgFUS temperature data obtained during cooling following a short (<25 s) heating pulse. The Gaussian SAR method can also use temperatures obtained during heating. Experiments were performed at low heating levels (ΔT∼10 °C) in ex vivo pork muscle and in vivo rabbit back muscle. The non-invasive MRgFUS thermal diffusivity estimates were compared with measurements from two standard invasive methods. Results: Both non-invasive methods accurately estimated thermal diffusivity when using MR temperature cooling data (overall ex vivo error <6%, in vivo <12%). Including heating data in the Gaussian SAR method further reduced errors (ex vivo error <2%, in vivo <3%). The significantly lower standard deviation values (p < 0.03) of the Gaussian SAR method indicated that it had better precision than the Gaussian temperature method. Conclusions: With repeated sonications, either MR-based method could provide accurate thermal diffusivity values for MRgFUS therapies. Fitting to more data simultaneously likely made the Gaussian SAR method less susceptible to noise, and using heating data helped it converge more consistently to the FUS fitting parameters and thermal diffusivity. These effects led to the improved precision of the Gaussian SAR method.