27 August 2010 in Advanced Materials
7 January 2013 in Applied Physics Letters
Metal-semiconductor-metal (MSM) photodetectors based on graphene/p-type Si Schottky junctions are fabricated and characterized. Thermionic emission dominates the transport across the junctions above 260 K with a zero-bias barrier height of 0.48 eV. The reverse-bias dependence of the barrier height is found to result mostly from the Fermi level shift in graphene. MSM photodetectors exhibit a responsivity of 0.11 A/W and a normalized photocurrent-to-dark current ratio of 4.55 × 104 mW−1, which are larger than those previously obtained for similar detectors based on carbon nanotubes. These results are important for the integration of transparent, conductive graphene electrodes into existing silicon technologies.
6 February 2013 in Nano Letters
15 August 2007 in Journal of Applied Physics
We have used Monte Carlo simulations to study the effects of nanotube alignment and measurement direction on the resistivity in single-walled carbon nanotube films. These films consist of multiple layers of conductive nanotube networks with percolative transport as the dominant conduction mechanism. We find that minimum resistivity occurs for a partially aligned rather than a perfectly aligned nanotube film. When nanotubes are strongly aligned, the film resistivity becomes highly dependent on the measurement direction. We also find that aligning the nanotubes too strongly or measuring the resistivity in a direction which is very different from the alignment direction causes the film to approach the percolation threshold, as evidenced by the inverse power law increase in resistivity. Furthermore, the location of the resistivity minimum and the values of the inverse power law critical exponents are not universal, but depend strongly on other nanotube and device parameters. To illustrate this explicitly, we have studied the effect of three parameters, namely, nanotube length, nanotube density per layer, and device length on the scaling of nanotube film resistivity with nanotube alignment and measurement direction. We find that longer nanotubes, denser films, and shorter device lengths decrease the alignment critical exponent and the alignment angle at which minimum resistivity occurs, but increase the measurement direction critical exponent. However, the amount of increase or decrease in the critical exponents or the minima locations is different for each parameter. We explain these results by simple physical and geometrical arguments. Characterizing and understanding the effects of alignment and measurement direction on the percolation resistivity in films and composites made up of one-dimensional conductors, such as nanotubes, give valuable insights into the optimal way to arrange these nanomaterials for potential applications in optoelectronics, sensors, and flexible microelectronics.
29 March 2007 in Physical Review B
We study the geometry-dependent resistivity scaling in single-walled carbon nanotube films as a function of nanotube and device parameters using Monte Carlo simulations. We first demonstrate that these simulations can model and fit recent experimental results on the scaling of nanotube film resistivity with device width. Furthermore, we systematically study the effect of four parameters; namely, tube-tube contact resistance to nanotube resistance ratio, nanotube density, nanotube length, and nanotube alignment on the film resistivity and its scaling with device width. Stronger width scaling is observed when the transport in the nanotube film is dominated by tube-tube contact resistance. Increasing the nanotube density decreases the film resistivity strongly and results in a higher critical exponent and a lower critical width. Increasing the nanotube length also reduces the film resistivity, but increases both the critical exponent and the critical width. In addition, the lowest resistivity occurs for a partially aligned rather than perfectly aligned nanotube film. Increasing the degree of alignment reduces both the critical exponent and the critical width. We systematically explain these observations, which are in agreement with previous experimental results, by simple physical and geometrical arguments. We also observe that, near the percolation threshold, the resistivity of the nanotube film exhibits an inverse power-law dependence on all of these parameters, which is a distinct signature of percolating conduction. However, the strength of resistivity scaling for each parameter is different, and it depends on how strongly a particular parameter changes the number of conduction paths in the film. Monte Carlo simulations, as presented in this paper, can help elucidate the effects of various parameters on percolating transport in films made up of one-dimensional conductors, which is an essential step towards understanding and characterizing the performance of these nanomaterials in electronic and optoelectronic devices.
23 November 2009 in Applied Physics Letters
Using a tunneling-percolation model and Monte Carlo simulations, we study the resistivity of graphene-based nanocomposites as a function of both graphene sheet and device parameters. We observe an inverse power law dependence of resistivity on device dimensions and volume fraction near the percolation threshold, and find that high aspect ratio graphene sheets result in a much lower resistivity, particularly at low sheet densities. Furthermore, we find that graphene sheet area affects nanocomposite resistivity more strongly than sheet density does. These results impart important fundamental insights for future experimental investigations and applications of graphene-based conductive nanocomposites.