15 December 2016 in Journal of the American Chemical Society
26 January 2021 in Journal of Physics D: Applied Physics
Plasma-generated hydroxyl radicals ( · OH) and oxygen atoms (O) produced by the COST reference plasma jet, a micro-scaled atmospheric pressure plasma jet, were investigated using a variety of experimental techniques. Several gas admixtures were studied to distinguish the contributions of the two reactive oxygen species. Large discrepancies between inferred aqueous · OH densities were noted when using a 2-hydroxyterephthalic acid (HTA) fluorescence assay and electron paramagnetic resonance (EPR) measurements with the spin trap 5,5-dimethyl-1-pyrroline N -oxide—especially when oxygen was present in the feed gas. A series of follow-up experiments including optical emission spectroscopy, H 2 O 2 quantification, and EPR measurements of atomic oxygen using the spin trap 2,2,6,6-tetramethylpiperidine, revealed that the inconsistencies between the measured aqueous · OH were likely due to the propensity of atomic oxygen to hydroxylate TA in a manner indistinguishable from · OH. This renders the HTA assay non-selective when both · OH radicals and atomic oxygen are present, which we report for all three gas admixtures in our experiments. Additionally, considerable degradation of both HTA and the spin adducts measured using EPR spectroscopy was apparent, meaning actual radical densities in the plasma-treated liquid may be considerably higher than implied. Degradation rates compared favorably to previously measured gas phase densities of atomic oxygen in the predecessor of the COST jet and reported degradation of other chemical probes. These results show the prolific role of atomic oxygen in plasma-induced liquid chemistry and caution against diagnostic techniques that are unable to account for it.
1 December 2013 in Surface and Coatings Technology
7 August 2017 in Plasma Sources Science and Technology
Electron neutral collision frequency is measured using both grounded and floating hairpin resonator probes in a 27 MHz parallel plate capacitively coupled plasma. Operating conditions are 0.1–2 Torr (13.3–267 Pa) in Ar, He, and Ar–He gas mixtures. The method treats the hairpin probe as a two wire transmission line immersed in a dielectric medium. Measurements are obtained using a pressure and sheath correction process by sweeping over assumed collision frequencies in order to obtain the measured collision frequency. Results are compared to hybrid plasma equipment module simulations and show good agreement.
1 January 2019 in Physics of Plasmas
In situ plasma diagnostics present the classical problem of the scientific measurement: how does one accurately measure a system without also perturbing it? The uncertainty in the degree of perturbation then reflects an inherent uncertainty in the diagnostic results. Microwave probes are no exception. This work discusses an experimental methodology for quantifying the local perturbation in hairpin resonator probe measurements. By pulsing the delivered power to a plasma, an electron density hairpin spike (HS) is readily detected at generator shutoff. The phenomenon is understood to arise from an apparent density rise as the plasma sheath collapses, thus raising the spatially averaged density measured between the hairpin tines. Other explanations for the density rise are eliminated, and the utility of the HS is presented. Under the conditions investigated, the HS provides an experimental comparison to a previous sheath correction factor developed by Sands et al.
23 January 2020 in Journal of Physics D: Applied Physics
A floating hairpin resonator probe is used to measure electron density within the radiofrequency cycle of a parallel plate capacitively coupled plasma at steady state. A time resolution capable of detecting electron density oscillations within the radiofrequency cycle is demonstrated. Electron density oscillations are observed at the drive frequency over a range of operating conditions including 10–250 mTorr (1.3–33 Pa) in argon driven at 13.56 or 27.12 MHz. Localized electron density oscillation amplitudes show moderate agreement with literature and fluid simulations near the powered electrode and disagreement in the plasma bulk. The technique is useful for studying electron heating mechanisms in radiofrequency discharges due to its high time resolution.