Jared Allen

Jared Allen

Auto-generated profile, based on publicly available information

Jared Allen

Oncimmune Ltd, Nottingham City Hospital, Nottingham, United Kingdom

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2012 in Tumor Biology
Verified
Journal Article
Open access
PDF file
CCCaroline J. Chapman
Caroline J. Chapman
GHGraham F. Healey
Graham F. Healey
AMAndrea Murray
Andrea Murray
PBPeter Boyle
Peter Boyle
CRChris Robertson
Chris Robertson
JRJohn F. R. Robertson
John F. R. Robertson
Tumor-associated autoantibodies (AAbs) have been described in patients with lung cancer, and the EarlyCDT®-Lung test that measures such AAbs is available as an aid for the early detection of lung cancer in high-risk populations. Improvements in specificity would improve its cost-effectiveness, as well as reduce anxiety associated with false positive tests. Samples from 235 patients with newly diagnosed lung cancer and matched controls were measured for the presence of AAbs to a panel of six (p53, NY-ESO-1, CAGE, GBU4-5, Annexin I, and SOX2) or seven (p53, NY-ESO-1, CAGE, GBU4-5, SOX2, HuD, and MAGE A4) antigens. Data were assessed in relation to cancer type and stage. The sensitivity and specificity of these two panels were also compared in two prospective consecutive series of 776 and 836 individuals at an increased risk of developing lung cancer. The six-AAb panel gave a sensitivity of 39 % with a specificity of 89 %, while the seven-AAb panel gave a sensitivity of 41 % with a specificity of 91 % which, once adjusted for occult cancers in the population, resulted in a specificity of 93 %. Analysis of these AAb assays in the at-risk population confirmed that the seven-AAb panel resulted in a significant increase in the specificity of the test from 82 to 90 %, with no significant change in sensitivity. The change from a six- to a seven-AAb assay can improve the specificity of the test and would result in a PPV of 1 in 8 and an overall accuracy of 92 %.

1 July 2011 in Cancer Prevention Research
Verified
Journal Article
Open access
PDF file
SLStephen Lam
Stephen Lam
PBPeter Boyle
Peter Boyle
GHGraham F. Healey
Graham F. Healey
PMPaul Maddison
Paul Maddison
LPLaura Peek
Laura Peek
JRJohn F.R. Robertson
John F.R. Robertson
Recent publications have reported the technical and clinical validation of EarlyCDT-Lung, an autoantibody test which detected elevated autoantibodies in 40% of lung cancers at diagnosis. This manuscript reports the results of EarlyCDT-Lung run on four new (postvalidation) data sets. The following four cohorts of patients (n = 574) with newly diagnosed lung cancer were identified: group 1 (n = 122), 100% small cell lung cancer (SCLC); group 2 (n = 249), 97% non-small cell lung cancer (NSCLC); group 3 (n = 122), 100% NSCLC; group 4 (n = 81), 62% NSCLC. Serum samples were obtained after diagnosis, prior to any anticancer treatment. Autoantibody levels were measured against a panel of six tumor-related antigens (p53, NY-ESO-1, CAGE, GBU4–5, Annexin 1, and SOX2) in the EarlyCDT-Lung panel and previously established cutoffs applied. In groups 2, 3, and 4, patients were individually matched by gender, age, and smoking history to a control individual with no history of malignant disease. Assay sensitivity was tested in relation to cancer type and stage, and in the matched normals to demographic variables. The autoantibody panel showed sensitivity/specificity of 57%/n.d (not done) for SCLC in group 1, 34%/87% for NSCLC in group 2, 31% and 84% for NSCLC in group 3, and 35%/89% for NSCLC and 43%/89% for SCLC in group 4. There was no significant difference in positivity of EarlyCDT-Lung and different lung cancer stages. These studies confirm the value of an autoantibody assay, EarlyCDT-Lung, as an aid to detecting lung cancer in patients at high risk of the disease. Cancer Prev Res; 4(7); 1126–34. ©2011 AACR.

15 March 2011 in Clinical Cancer Research
Verified
Journal Article
Closed access
PDF file
CCCaroline J. Chapman
Caroline J. Chapman
ATAlison J. Thorpe
Alison J. Thorpe
AMAndrea Murray
Andrea Murray
CPCeline B. Parsy-Kowalska
Celine B. Parsy-Kowalska
JAJared Allen
Jared Allen
JRJohn F. R. Robertson
John F. R. Robertson
Purpose: We investigated the presence of autoantibodies as immunobiomarkers to a panel of tumor-associated antigens in a group of individuals with small cell lung cancer (SCLC), a disease group that has a poor overall cancer prognosis and therefore may benefit most from early diagnosis. Experimental Design: Sera from 243 patients with confirmed SCLC and normal controls matched for age, sex, and smoking history were analyzed for the presence of these early immunobiomarkers (i.e., autoantibodies to p53, CAGE, NY-ESO-1, GBU4-5, Annexin I, SOX2, and Hu-D) by ELISA. Results: Autoantibodies were seen to at least 1 of 6 antigens in 55% of all the SCLC patients' sera tested, with a specificity of 90% compared with controls. Using a higher assay cutoff to achieve a specificity of 99%, autoantibodies were still detectable in 42% of SCLC patients (receiver operator characteristic area under the curve = 0.76). There was no significant difference in sensitivity when analyzed by stage of the cancer or by patient age or gender. The frequency of autoantibodies to individual antigens varied, ranging from 4% for GBU4-5 to 35% for SOX2. Levels of Annexin I autoantibodies were not elevated in patients with SCLC. Antibodies were also detected in 4 separate patients whose sera were taken up to 3 months before tumor diagnosis. Conclusion: The presence of an autoantibody to one or more cancer-associated antigens may provide an important addition to the armamentarium available to the clinician to aid early detection of SCLC in high-risk individuals. Clin Cancer Res; 17(6); 1474–80. ©2011 AACR.

13 December 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
IMIsabel K. Macdonald
Isabel K. Macdonald
AMAndrea Murray
Andrea Murray
GHGraham F. Healey
Graham F. Healey
CPCeline B. Parsy-Kowalska
Celine B. Parsy-Kowalska
JAJared Allen
Jared Allen
JRJohn F. R. Robertson
John F. R. Robertson
The National Lung Screening Trial showed that CT screening for lung cancer led to a 20% reduction in mortality. However, CT screening has a number of disadvantages including low specificity. A validated autoantibody assay is available commercially (EarlyCDT®-Lung) to aid in the early detection of lung cancer and risk stratification in patients with pulmonary nodules detected by CT. Recent advances in high throughput (HTP) cloning and expression methods have been developed into a discovery pipeline to identify biomarkers that detect autoantibodies. The aim of this study was to demonstrate the successful clinical application of this strategy to add to the EarlyCDT-Lung panel in order to improve its sensitivity and specificity (and hence positive predictive value, (PPV)). Serum from two matched independent cohorts of lung cancer patients were used (n = 100 and n = 165). Sixty nine proteins were initially screened on an abridged HTP version of the autoantibody ELISA using protein prepared on small scale by a HTP expression and purification screen. Promising leads were produced in shake flask culture and tested on the full assay. These results were analyzed in combination with those from the EarlyCDT-Lung panel in order to provide a set of re-optimized cut-offs. Five proteins that still displayed cancer/normal differentiation were tested for reproducibility and validation on a second batch of protein and a separate patient cohort. Addition of these proteins resulted in an improvement in the sensitivity and specificity of the test from 38% and 86% to 49% and 93% respectively (PPV improvement from 1 in 16 to 1 in 7). This is a practical example of the value of investing resources to develop a HTP technology. Such technology may lead to improvement in the clinical utility of the EarlyCDT­-Lung test, and so further aid the early detection of lung cancer.

5 August 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CMCatrin H. Middleton
Catrin H. Middleton
WIWilliam L. Irving
William L. Irving
JRJohn F. R. Robertson
John F. R. Robertson
AMAndrea Murray
Andrea Murray
CPCeline B. Parsy-Kowalska
Celine B. Parsy-Kowalska
CCCaroline J. Chapman
Caroline J. Chapman
Individuals with liver disease, and especially those with Hepatitis B or C, are at an increased risk of developing hepatocellular carcinoma (HCC) which is the third most common cause of cancer-related death worldwide. Inadequate screening tests largely account for presentation of advanced tumours and high mortality rates. Early detection of HCC amongst high-risk groups is paramount in improving prognosis. This research aimed to further characterise the previously described humoral immune response raised to tumour-associated antigens (TAAs) in the serum of patients with HCC. Serum from 96 patients with confirmed HCC, 96 healthy controls matched for age and sex, 78 patients with confirmed liver cirrhosis and 91 patients with confirmed chronic liver disease were analysed for the presence of IgG autoantibodies raised to 41 recombinant TAAs/antigen fragments by ELISA. Varying autoantibody specificities (97–100%) and sensitivities (0–10%) were observed to individual TAAs. A 21-antigen panel achieved a specificity of 92% and sensitivity of 45% for the detection of HCC. This same panel identified 21% of 169 high-risk controls as having elevated autoantibody levels. A reproducible panel of 10 antigens achieved a specificity of 91% and sensitivity of 41% in HCC. 15% of 152 high-risk controls gave positive results with this panel. This minimally invasive blood test has the potential to offer advantages over currently available tools for the identification of HCC amongst pre-disposed patients. Results are comparable to current gold standards in HCC (Ultrasonography) and to similar tests in other cancers (EarlyCDT-Lung).

19 October 2020 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Open access
CCCaroline J. Chapman
Caroline J. Chapman
ABAyan Banerjea
Ayan Banerjea
DHDavid J Humes
David J Humes
JAJaren Allen
Jaren Allen
SOSimon Oliver
Simon Oliver
JMJoanne R. Morling
Joanne R. Morling
Objectives: Currently, NICE recommends the use of faecal immunochemical test (FIT) at faecal haemoglobin concentrations (f-Hb) of 10 μg Hb/g faeces to stratify for colorectal cancer (CRC) risk in symptomatic populations. This f-Hb cut-off is advised across all analysers, despite the fact that a direct comparison of analyser performance, in a clinical setting, has not been performed. Methods: Two specimen collection devices (OC-Sensor, OC-S; HM-JACKarc, HM-J) were sent to 914 consecutive individuals referred for follow up due to their increased risk of CRC. Agreement of f-Hb around cut-offs of 4, 10 and 150 µg Hb/g faeces and CRC detection rates were assessed. Two OC-S devices were sent to a further 114 individuals, for within test comparisons. Results: A total of 732 (80.1%) individuals correctly completed and returned two different FIT devices, with 38 (5.2%) CRCs detected. Median f-Hb for individuals diagnosed with and without CRC were 258.5 and 1.8 µg Hb/g faeces for OC-S and 318.1 and 1.0 µg Hb/g faeces for HM-J respectively. Correlation of f-Hb results between OC-S/HM-J over the full range was rho=0.74, p<0.001. Using a f-Hb of 4 µg Hb/g faeces for both tests found an agreement of 88.1%, at 10 µg Hb/g faeces 91.7% and at 150 µg Hb/g faeces 96.3%. A total of 114 individuals completed and returned two OC-S devices; correlation across the full range was rho=0.98, p<0.001. Conclusions: We found large variations in f-Hb when different FIT devices were used, but a smaller variation when the same FIT device was used. Our data suggest that analyser-specific f-Hb cut-offs are applied with regard to clinical decision making, especially at lower f-Hb.