Huicong Shen

Huicong Shen

Auto-generated profile, based on publicly available information

Huicong Shen

Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2019 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
ZQZ. Qiao
Z. Qiao
XZX. Zhao
X. Zhao
KWK. Wang
K. Wang
YZYisen Zhang
Yisen Zhang
DFD. Fan
D. Fan
LALin Ai
Lin Ai
BACKGROUND AND PURPOSE: Both 11C-methionine PET/CT and DSC-PWI could be used to differentiate radiation injury from recurrent brain tumors. Our aim was to assess the performance of MET PET/CT and DSC-PWI for differentiation of recurrence and radiation injury in patients with high-grade gliomas and to quantitatively analyze the diagnostic values of PET and PWI parameters. MATERIALS AND METHODS: Forty-two patients with high-grade gliomas were enrolled in this study. The final diagnosis was determined by histopathologic analysis or clinical follow-up. PWI and PET parameters were recorded and compared between patients with recurrence and those with radiation injury using Student t tests. Receiver operating characteristic and logistic regression analyses were used to determine the diagnostic performance of each parameter. RESULTS: The final diagnosis was recurrence in 33 patients and radiation injury in 9. PET/CT showed a patient-based sensitivity and specificity of 0.909 and 0.556, respectively, while PWI showed values of 0.667 and 0.778, respectively. The maximum standardized uptake value, mean standardized uptake value, tumor-to-background maximum standardized uptake value, and mean relative CBV were significantly higher for patients with recurrence than for patients with radiation injury. All these parameters showed a high discriminative power in receiver operating characteristic analysis. The optimal cutoff values for the tumor-to-background maximum standardized uptake value and mean relative CBV were 1.85 and 1.83, respectively, and corresponding sensitivities and specificities for the diagnosis of recurrence were 0.97 and 0.667 and 0.788 and 0.88, respectively. Areas under the curve for the tumor-to-background maximum standardized uptake value and mean relative CBV were 0.847 ± 0.077 and 0.845 ± 0.078, respectively. Combined assessment of the tumor-to-background maximum standardized uptake value and mean relative CBV showed the largest area under the curve (0.953 ± 0.031), with corresponding sensitivity and specificity of 0.848 and 1.0, respectively. CONCLUSIONS: Both 11C-methionine PET/CT and PWI are equally accurate in the differentiation of recurrence from radiation injury in patients with high-grade gliomas, and a combination of the 2 modalities could result in increased diagnostic accuracy.

1 March 2019 in European Journal of Radiology
Verified
Journal Article
Closed access
LHLiang Han
Liang Han
SWSiyu Wang
Siyu Wang
YMYanwei Miao
Yanwei Miao
HSHuicong Shen
Huicong Shen
YGYan Guo
Yan Guo
QSQingwei Song
Qingwei Song

13 May 2013 in PLOS ONE
Verified
Journal Article
Open access
MLMeng Li
Meng Li
JHJiani Hu
Jiani Hu
YMYanwei Miao
Yanwei Miao
HSHuicong Shen
Huicong Shen
DTDingbo Tao
Dingbo Tao
EHE. Mark Haacke
E. Mark Haacke
Cerebral blood oxygenation level is critical for following the evolution of stroke patients. The purpose of this study was to investigate the feasibility of measuring changes in blood oxygen levels for patients with acute stroke using SWI and to compare these changes with the patient's recovery over time. A total 30 MRI scans was performed on 10 acute ischemic stroke patients. Every patient was followed at three time points: less than 24 hours; 2–3 weeks after stroke and 2 months after stroke. Both MRI scan and NIH stroke scale (NIHSS) were acquired for each patient at all three time points. Oxygen saturation changes were derived from phase values differences (Δφ) measured over 10 veins from each hemisphere for all 10 patients over 3 time points. The correlation of oxygen saturation and NIHSS was further evaluated. The stroke affected side of the brain showed moderate (r = −0.62) to strong (r = −0.70) correlation between the oxygenation change and NIHSS change. The oxygen saturation change from the normal side of the brain had essentially no association with recovery (r = −0.02 and−0.31). The results suggest that increases in oxygen saturation correspond to improved outcome and reductions in oxygen saturation correspond to worse outcome. High resolution SWI provided a novel method to measure changes in oxygenation change of the human brain in vivo. By using the phase values from the veins, both spatial and temporal information can be found that relates to patient outcome post stroke.

1 January 2020 in BioMed Research International
Verified
Journal Article
Open access
JDJunyi Dong
Junyi Dong
MYMeimei Yu
Meimei Yu
YMYanwei Miao
Yanwei Miao
HSHuicong Shen
Huicong Shen
YSYi Sui
Yi Sui
LXLizhi Xie
Lizhi Xie
Background. Intracranial solitary fibrous tumor(SFT)/hemangiopericytoma (HPC) is an aggressive malignant tumor originating from the intracranial vasculature. Angiomatous meningioma (AM) is a benign tumor with a good prognosis. The imaging manifestations of the two are very similar. Thus, novel noninvasive diagnostic method is urgently needed in clinical practice. Texture analysis and model building through machine learning may have good prospects. Aim. To evaluate whether a 3D‐MRI texture feature model could be used to differentiate malignant intracranial SFT/HPC from AM. Method. A total of 97 patients with SFT/HPC and 95 with AM were included in this study. Patients from each group were randomly divided into the train (70%) and test (30%) sets. ROIs were drawn along the edge of the tumor on each section of T1WI, T2WI, and contrasted T1WI using ITK‐SNAP software. The segmented image was imported into the AK software for texture feature extraction, and the 3D ROI signal intensity histograms of T1WI, T2WI, and contrasted T1WI were automatically obtained along with all the parameters. Modeling was performed using the language R. Confusion matrix was used to analyze the accuracy of the model. ROC curve was constructed to assess the grading ability of the logistic regression model. Results. After Lasso dimension reduction, 5, 9, and 7 texture features were extracted from T1WI, T2WI, and contrasted T1WI, respectively; additional 8 texture features were extracted from the combined sequence for modeling. The ROC analyses on four models resulted in an area under the curve (AUC) of 0.885 (sensitivity 76.1%, specificity 87.9%) for T1WI model, 0.918 (73.1%, 95.5%) for T2WI model, 0.815 (55.2%, 93.9%) for contrasted T1WI model, and 0.959 (92.5%, 84.8%) for the combined sequence model and were enough to correctly distinguish the two groups in 71.2%, 81.4%, 69.5%, and 83.1% of cases in test set, respectively. Conclusions. The radiological model based on texture features could be used to differentiate SFT/HPC from AM.

1 July 2015 in Psychiatry Research
Verified
Journal Article
Closed access
XWXinhua Wei
Xinhua Wei
HSHuicong Shen
Huicong Shen
JRJiliang Ren
Jiliang Ren
WLWenhua Liu
Wenhua Liu
RYRuimeng Yang
Ruimeng Yang
XJxinqing jiang
xinqing jiang

29 February 2024 in Journal of Neuro-Oncology
Verified
Journal Article
Closed access
PDF file
MYMeimei Yu
Meimei Yu
YGYing Ge
Ying Ge
ZWZixuan Wang
Zixuan Wang
YZYang Zhang
Yang Zhang
XHXinyi Hou
Xinyi Hou
HSHuicong Shen
Huicong Shen