15 August 2017 in Nature Communications
In vitro models that better reflect in vivo epithelial barrier (patho-)physiology are urgently required to predict adverse drug effects. Here we introduce extracellular matrix-supported intestinal tubules in perfused microfluidic devices, exhibiting tissue polarization and transporter expression. Forty leak-tight tubules are cultured in parallel on a single plate and their response to pharmacological stimuli is recorded over 125 h using automated imaging techniques. A study comprising 357 gut tubes is performed, of which 93% are leak tight before exposure. EC50-time curves could be extracted that provide insight into both concentration and exposure time response. Full compatibility with standard equipment and user-friendly operation make this Organ-on-a-Chip platform readily applicable in routine laboratories.
15 June 2022 in Angiogenesis
With recent progress in modeling liver organogenesis and regeneration, the lack of vasculature is becoming the bottleneck in progressing our ability to model human hepatic tissues in vitro. Here, we introduce a platform for routine grafting of liver and other tissues on an in vitro grown microvascular bed. The platform consists of 64 microfluidic chips patterned underneath a 384-well microtiter plate. Each chip allows the formation of a microvascular bed between two main lateral vessels by inducing angiogenesis. Chips consist of an open-top microfluidic chamber, which enables addition of a target tissue by manual or robotic pipetting. Upon grafting a liver microtissue, the microvascular bed undergoes anastomosis, resulting in a stable, perfusable vascular network. Interactions with vasculature were found in spheroids and organoids upon 7 days of co-culture with space of Disse-like architecture in between hepatocytes and endothelium. Veno-occlusive disease was induced by azathioprine exposure, leading to impeded perfusion of the vascularized spheroid. The platform holds the potential to replace animals with an in vitro alternative for routine grafting of spheroids, organoids, or (patient-derived) explants.
15 April 2021 in Lab on a Chip
We present an instrument for simultaneously measuring TEER in up to 80 perfused epithelial tubules on an OrganoPlate. The sensitivity, speed and ease of use enables screening of tubules during formation, drug exposure and inflammatory processes.
15 January 2020 in Journal of Crohn's and Colitis
Background: One of the major functions of the human intestine is to provide a protective epithelial barrier between the body and digestive environment. Additionally, the interplay of commensal microbes of the gut microbiome with the gut tissue and host immune system significantly contributes to intestinal homeostasis. Crohn’s disease and ulcerative colitis, collectively referred to as inflammatory bowel diseases, are both associated with increased permeability of the epithelial barrier and dysregulated immune response. Great efforts have been made to develop both in vitro and in vivo models of the human intestine in order to understand the development and underlying pathogenesis of IBD. These efforts have provided valuable insights into multiple aspects of the disease. However, none of these models has been able to capture the complexity and multifactorial nature of IBD. Animal models generally fail to accurately predict the efficacy and toxicity of novel compounds in human tissues, while in vitro human intestinal models developed on porous membranes within Transwell inserts fail to accurately recapitulate and mimic key aspects of the in vivo situation. Methods: Here, we present the development and characterisation of a 3D multicellular perfused intestine-on-a-chip model in a microfluidic platform, the OrganoPlate®, and its application for investigating intestinal inflammation. The model described here comprises a coculture of Caco-2 and mucus-secreting HT29-MTX cells in the top compartment of the chip and a coculture of immune-competent cells THP-1 and MUTZ-3 in the bottom compartment, lining a collagen-I ECM in the middle. Results: We show that the Caco-2 and HT29-MTX coculture form confluent and polarised tubular structures against the collagen-I ECM in the OrganoPlate®, with a stable barrier function over time as well as the capability to secrete mucus. By exposing the cultures to TNFα and/or IL-1β, we were able to induce an inflammatory state, characterised by cytokine release (IL-8) and a decrease in trans-epithelial electrical resistance. Finally, we proved the applicability of the model in screening anti-inflammatory compounds by its reversibility. Using a well-known anti-inflammatory drug, TPCA-1, we were able to prevent cytokine-induced inflammation. This result was evident from the decreased secretion of IL-8 and retention of barrier function in treated cultures, similar to that observed in untreated cultures. Conclusion: Overall, this complex 3D multicellular perfused intestine-on-a-chip model provides the versatile modularity of mimicking key features of intestinal inflammation and can, therefore, further support drug screening efforts and provide a platform for personalised medicine.