3 November 2023 in Clinical Neurophysiology
To develop an artificial neural network (ANN) for classification of motor unit action potential (MUAP) duration in real-word, unselected and uncleaned needle electromyography (n-EMG) recordings. Two nested ANN models were trained, the first discerning muscle rest, contraction and artifacts in n-EMG recordings from 2674 individual muscles from 326 patients obtained as part of daily care. The second ANN model subsequently used segments labeled as contraction for prediction of prolonged, normal and shortened MUAPs. Model performance was assessed in one internal and two external validation datasets of 184, 30 and 50 muscles, respectively. The first model discerned rest, contraction and artifacts with an accuracy of 96%. The second model predicted prolonged, normal and shortened MUAPs with an accuracy of 67%, 83% and 68% in the different validation sets. We developed a two-step ANN that classifies rest, muscle contraction and artifacts from real-world n-EMG recordings with very high accuracy. MUAP duration classification had moderate accuracy. This is the first study to show that an ANN can classify MUAPs in real-world n-EMG recordings highlighting the potential for AI assisted MUAP classification as a clinical tool.
30 October 2024 in Movement Disorders
18 January 2026 in Brain Stimulation
1 May 2026 in Movement Disorders Clinical Practice
1 October 2024 in Neuromodec Journal
1 December 2022 in Journal of Radiotherapy in Practice
Aim: This study aims to compare the gating signals of patients with lung cancer recorded during the planning computed tomography scan with the ones recorded during treatment fractions. The results provide insights into how representative the respiratory signals from the planning scan are for radiation dose partitioning. Materials and methods: The amplitude and frequency of the respiratory signals of 29 patients with lung carcinoma were analysed and compared with the amplitude and frequency of those recorded during their planning scans. Moreover, a cross-correlation analysis was performed between the difference between the planning scan and fractions and features from the planning scan. Results: Two patients showed significantly different amplitude and frequency during treatment fractions compared to those from the planning scan. These patients showed low variances in frequency and amplitude during the different fractions. The difference between planning scan and fractions is correlated with the variances within the planning scan. Findings: Respiratory signals can differ between the planning scan and the fractions. In this case, a new planning scan may be beneficial. The respiratory signals from the planning scan may be predictive of whether the planning scan will be representative and usable as a control measure during radiotherapy fractions.