Luis Reyes-Gónzalez

Luis Reyes-Gónzalez

Auto-generated profile, based on publicly available information

Luis Reyes-Gónzalez

Photonics Engineering Group, University of Cantabria, 39005 Santander, Spain

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Ageing Research Reviews
Verified
Journal Article
Open access
FAFrancisco Anabitarte-García
Francisco Anabitarte-García
LRLuis Reyes-González
Luis Reyes-González
LRLuis Rodríguez-Cobo
Luis Rodríguez-Cobo
CVCarlos Fernández Viadero
Carlos Fernández Viadero
SSSilvia Somonte-Segares
Silvia Somonte-Segares
JLJosé M. López-Higuera
José M. López-Higuera
This work analyses different concepts for frailty diagnosis based on affordable standard technology such as smartphones or wearable devices. The goal is to provide ideas that go beyond classical diagnostic tools such as magnetic resonance imaging or tomography, thus changing the paradigm; enabling the detection of frailty without expensive facilities, in an ecological way for both patients and medical staff and even with continuous monitoring. Fried's five-point phenotype model of frailty along with a model based on trials and several classical physical tests were used for device classification. This work provides a starting point for future researchers who will have to try to bridge the gap separating elderly people from technology and medical tests in order to provide feasible, accurate and affordable tools for frailty monitoring for a wide range of users.

27 March 2015 in Journal of Intelligent Material Systems and Structures
Verified
Journal Article
Open access
GSGuillermo Iglesias Salto
Guillermo Iglesias Salto
AAAndrés Roldán Aranda
Andrés Roldán Aranda
LRLuis Reyes
Luis Reyes
LRLaura Rodríguez-Arco
Laura Rodríguez-Arco
JDJuan Dg Durán
Juan Dg Durán
In this work, we study the stability behavior of composite magnetorheological fluids consisting of magnetic (iron) and non-magnetic (poly(methylmethacrylate)) particles dispersed in mineral oil. Because of the opacity of the suspensions, optical methods traditionally employed for evaluation of the gravitational settling in colloidal suspensions are not suitable for sedimentation follow-up in this case. For this reason, we use an alternative method based on the evaluation of the resonant frequency of the inductance of a thin coil surrounding the sample. The movement of the coil along the height of the container at specified steps and time intervals allows obtaining information about the local volume fraction of particles inside the tube. The obtained successive profiles for the multi-component suspensions show a decrease of the iron particle settling and of the initial rate of settling as the poly(methylmethacrylate) volume fraction is increased. Finally, the increase of the poly(methylmethacrylate) concentration gives rise to an improvement of the rheological properties upon magnetic field application for a given concentration of iron. Both a strong rheological response and a good colloidal stability are essential for practical applications.

27 September 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
LRLuis Reyes-Gonzalez
Luis Reyes-Gonzalez
LRLuis Rodriguez-Cobo
Luis Rodriguez-Cobo
Jose Lopez-HigueraJose Lopez-Higuera
Jose Lopez-Higuera
The ballistocardiogram is a graphic representation of the movements of the body associated with cardiac activity. In this paper, a ten minutes ballistocardiogram have been captured for ten different volunteers with a polymer optical fiber (POF) specklegram sensor. This transducer, which is composed by a CCD camera, a laser emitting diode and two meters of POF, allows to capture the ballistocardiogram by analyzing how the induced speckle pattern changes over the time. These changes are related to cardiac activity. Several processing methods have been compared to determine which method achieve the best performance: Complex Cepstrum, Power of Spectral Density (PSD), Pam-Tompkins algorithm, Wavelet, Autocorrelation, Savitzky-Golay filter, Mean Absolute Deviation and Hilbert transform. Accuracy and resources consumption have been characterized and compared for these methods. Hilbert, PSD and Savitzky-golay exhibit both small error and computational cost. This paper describes a baseline for main frequency determination of POF-based ballistocardiogram signals in real time.

28 August 2019
Verified
Conference Paper
Open access
PDF file
LGLuis Reyes González
Luis Reyes González
FGFrancisco Anabitarte García
Francisco Anabitarte García
EREusebio Real
Eusebio Real
LCLuis Rodriguez Cobo
Luis Rodriguez Cobo
MLMauro Lomer
Mauro Lomer
JHJosé Miguel López Higuera
José Miguel López Higuera
Continuous patient monitoring has been evidenced as very beneficious for reducing degeneration1. Due to this, a POF specklegram sensor has been developed based on a previous work2. This work presents a comparative between analysis methods of the specklegram signal for achieving a precise and robust non-contact monitor system. Two different techniques have been used: one based on the Fast Fourier Transform (FFT) and the other based on the Hilbert Transform (HT). Each technique has been employed with two different methods, for heart rate and breath rhythm. The different algorithms are tested on 10 volunteers of different ages and sex.

1 January 2021
Verified
Conference Paper
Closed access
PDF file
LRLuis Reyes-Gónzalez
Luis Reyes-Gónzalez
FAFrancisco Anabitarte-Garćıa
Francisco Anabitarte-Garćıa
LRLuis Rodŕıguez-Cobo
Luis Rodŕıguez-Cobo
MLMauro Lomer
Mauro Lomer
JLJosé Miguel López-Higuera
José Miguel López-Higuera
This work presents a new analysis methods of the specklegram signal and its comparative with other method for achieving a precise and robust non-contact pulse monitor system.

1 January 2021
Verified
Conference Paper
Closed access
PDF file
LRLuis Reyes-Gónzalez
Luis Reyes-Gónzalez
FAFrancisco Anabitarte-Garćıa
Francisco Anabitarte-Garćıa
LRLuis Rodŕıguez-Cobo
Luis Rodŕıguez-Cobo
MLMauro Lomer
Mauro Lomer
JLJosé Miguel Lopez-Higúera
José Miguel Lopez-Higúera
This works compares how different light sources affect to the speckle pattern obtained into a specklegram system developed to monitorize pulse.