Huayang Sai

Huayang Sai

Auto-generated profile, based on publicly available information

Huayang Sai

School of Advanced Manufacturing and Robotics Peking University Beijing China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications


6 August 2023 in International Journal of Robust and Nonlinear Control
Verified
Journal Article
Closed access
HSHuayang Sai
Huayang Sai
ZXZhenbang Xu
Zhenbang Xu
JCJingkai Cui
Jingkai Cui

30 January 2023 in International Journal of Control, Automation, and Systems
Verified
Journal Article
Closed access
PDF file
HSHuayang Sai
Huayang Sai
ZXZhenbang Xu
Zhenbang Xu
EZEnyang Zhang
Enyang Zhang
CHChunyang Han
Chunyang Han
YYYang Yu
Yang Yu

20 November 2024 in Advanced Functional Materials
Verified
Journal Article
Closed access
LWlinlin wang
linlin wang
HSHuayang Sai
Huayang Sai
YTYi‐Yang Tang
Yi‐Yang Tang
BLBin Li
Bin Li
Lei WangLei Wang
Lei Wang
Tianyun HuangTianyun Huang
Tianyun Huang

8 June 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
HSHuayang Sai
Huayang Sai
LWLijuan Wang
Lijuan Wang
JZJie Zhang
Jie Zhang
CXChengkai Xia
Chengkai Xia
ZXZhenbang Xu
Zhenbang Xu
This study presents a portable device that ensures precise contact force between a subject and a probe to improve the stability and reproducibility of ultrasound (US) acquisition. The mechanical portion of the device includes a servo motor, gears, and a ball screw linear actuator; two photoelectric switches are used to limit the stroke. A combined force and position control system is developed, and a pressure threshold is introduced to reduce the chattering of the system so that it can be applied to US examinations of tissues of different stiffness levels. Force control experiments were conducted on the device, and the results showed that the device can overcome the chattering of a physician’s hand and movement caused by a subject’s respiration. Additionally, the stability of the US acquisition was substantially improved. Based on clinical trials on humans, this device was observed to improve the consistency of ultrasonic results and the repeatability of images, and it assisted sonographers with maintaining suitable contact force and improving imaging quality. The device can either be handheld by a physician or easily integrated with a manipulator as an autonomous robotic US acquisition device, thereby validating its potential for US applications.