Joaquin Andres-Porras

Joaquin Andres-Porras

Auto-generated profile, based on publicly available information

Joaquin Andres-Porras

Applied Optics Complutense Group, Optics Department, Faculty of Physics, Universidad Complutense de Madrid, Plaza de las Ciencias, 1, 28040 Madrid, Spain

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2025 in Optics and Lasers in Engineering
Verified
Journal Article
Open access
ASAngela Soria-Garcia
Angela Soria-Garcia
LSLUIS MIGUEL SANCHEZ-BREA
LUIS MIGUEL SANCHEZ-BREA
JHJesus del Hoyo
Jesus del Hoyo
JAJoaquin Andres-Porras
Joaquin Andres-Porras
Javier AldaJavier Alda
Javier Alda

14 May 2025 in Photonics
Verified
Journal Article
Open access
PDF file
VPVeronica Pastor-Villarrubia
Veronica Pastor-Villarrubia
ASAngela Soria-Garcia
Angela Soria-Garcia
JAJoaquin Andres-Porras
Joaquin Andres-Porras
JHJesus del Hoyo
Jesus del Hoyo
MEMahmoud Hamdy Elshorbagy
Mahmoud Hamdy Elshorbagy
Javier AldaJavier Alda
Javier Alda
This study reports the experimental validation of several designs of photon sieves with focusing capabilities. These permeable optical elements were implemented with a spatial light modulator working in pure-amplitude mode. The focal region was scanned using a traveling stage, holding a camera. Using this experimental setup, we characterized the focal region of the photon sieves and determined some parameters of interest, such as the depth of focus and the transverse extent of the focal region. These parameters and their evolution were measured and analyzed to compare the optical performance of different designs. Moreover, the permeability of the mask was also evaluated and is included in the discussion. When the photon sieve is intended to be used as an optical element for the monitoring of running fluids, one of the designs studied, labeled the Ring-by-Ring method, behaves in a quite balanced manner and thus has become the preferred choice. Through simulations for a refractometric sensor, we obtained the Figure of Merit of the Ring-by-Ring mask, which reached a maximum value of 7860 RIU−1, which is competitive with plasmonic sensing devices.

18 July 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
IDInes Diaz-Garcia
Ines Diaz-Garcia
JHJesus del Hoyo
Jesus del Hoyo
JAJoaquin Andres-Porras
Joaquin Andres-Porras
ASAngela Soria-Garcia
Angela Soria-Garcia
Javier AldaJavier Alda
Javier Alda
LSLUIS MIGUEL SANCHEZ-BREA
LUIS MIGUEL SANCHEZ-BREA
We present a common-path interferometer for measuring the retardance and azimuth of optical waveplates and liquid crystals. It is inherently immune to instabilities typical of other kind of interferometers and without the need for additional pre-characterized waveplates. The parameters of interest are calculated from the fringe pattern displacement produced when rotating the waveplate. We demonstrate this concept with two devices: a Young’s double-slit interferometer with orthogonally oriented linear polarizers at each slit, and a Wollaston prism that splits the incoming beam into two orthogonally polarized components. We have numerically analysed different configurations with ideal and non-ideal polarizers, and waveplates. This study demonstrates the need of polarizers with very large extinction ratio to increase the accuracy of the retardance measurement. Experimentally, we have built both interferometers considering and removing the effect caused by tilted or wedged elements. These experimental realizations of the two common-path interferometers allowed us to analyse for several commercial waveplates, obtaining fit errors below 0.1\text{°} and repeatabilities usually below 1\text{°} for the retardance. The azimuth uncertainties remain close to 0.02\text{°} and 0.1\text{°} for the fit and repeatability errors, respectively. When characterizing a liquid crystal variable retarder using the Wollaston prism interferometer we prove that this configuration is the most accurate and versatile. All experimental results obtained with our approach show good agreement with those measured using Mueller polarimetry.

4 February 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
IDInes Diaz-Garcia
Ines Diaz-Garcia
JHJesus del Hoyo
Jesus del Hoyo
JAJoaquin Andres-Porras
Joaquin Andres-Porras
ASAngela Soria-Garcia
Angela Soria-Garcia
Javier AldaJavier Alda
Javier Alda
LSLUIS MIGUEL SANCHEZ-BREA
LUIS MIGUEL SANCHEZ-BREA
We present a common-path interferometer for measuring the retardance and azimuth of optical waveplates and liquid crystals, inherently immune to instabilities typical of other kind of interferometers and without the need for additional pre-characterized waveplates. The parameters of interest are calculated from the fringe pattern displacement produced when rotating the waveplate. We demonstrate this concept with two devices: a Young’s double-slit interferometer with orthogonally oriented linear polarizers at each slit, and a Wollaston prism that splits the incoming beam into two orthogonally polarized components. To gain some insight in the advantages of the method, we have numerically analyzed the e ect of using non-ideal polarizers in the measurement process, demonstrating that using polarizers with very low extinction coe cient is crucial for the accuracy of the determination in the retardance. Additionally, for a more in-depth characterization, we have considered the case of ideal polarizers, but waveplates presenting di erent grades of diattenuation. Also, we have built both interferometers considering and removing the e ect caused by tilted or wedged elements. These experimental realizations of the two common-path interferometers allowed us to analyze for several commercial waveplates, obtaining t errors below 0.1º and repeatabilities usually below 1º for the retardance. The azimuth uncertainties remain close to 0.02º and 0.3º for the t and repeatabilities errors, respectively. We have also characterized a liquid crystal variable retarder using the Wollaston prism interferometer as it has proven to be the most accurate and versatile method. All experimental results obtained with our approach show good agreement with those measured using Mueller polarimetry.