John N. Morelli

John N. Morelli

Auto-generated profile, based on publicly available information

John N. Morelli

Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, USA

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2011 in RadioGraphics
Verified
Journal Article
Closed access
JMJohn N. Morelli
John N. Morelli
VRVal M. Runge
Val M. Runge
FAFei Ai
Fei Ai
UAUlrike Attenberger
Ulrike Attenberger
LVLan Vu
Lan Vu
JKJohn E. Kirsch
John E. Kirsch
As clinical magnetic resonance (MR) imaging becomes more versatile and more complex, it is increasingly difficult to develop and maintain a thorough understanding of the physical principles that govern the changing technology. This is particularly true for practicing radiologists, whose primary obligation is to interpret clinical images and not necessarily to understand complex equations describing the underlying physics. Nevertheless, the physics of MR imaging plays an important role in clinical practice because it determines image quality, and suboptimal image quality may hinder accurate diagnosis. This article provides an image-based explanation of the physics underlying common MR imaging artifacts, offering simple solutions for remedying each type of artifact. Solutions that have emerged from recent technologic advances with which radiologists may not yet be familiar are described in detail. Types of artifacts discussed include those resulting from voluntary and involuntary patient motion, magnetic susceptibility, magnetic field inhomogeneities, gradient nonlinearity, standing waves, aliasing, chemical shift, and signal truncation. With an improved awareness and understanding of these artifacts, radiologists will be better able to modify MR imaging protocols so as to optimize clinical image quality, allowing greater confidence in diagnosis.

1 August 2013 in Investigative Radiology
Verified
Journal Article
Closed access
HMHenrik J. Michaely
Henrik J. Michaely
JMJohn N. Morelli
John N. Morelli
JBJohannes Budjan
Johannes Budjan
PRPhilipp Riffel
Philipp Riffel
DNDominik Nickel
Dominik Nickel
UAUlrike I. Attenberger
Ulrike I. Attenberger
The purpose of this study was to assess the feasibility and image quality of a novel, highly accelerated T1-weighted sequence for time-resolved imaging of the abdomen during the first pass of contrast media transit using controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) under sampling, view-sharing techniques, and Dixon water-fat separation (CAIPRINHA-Dixon-time-resolved imaging with interleaved stochastic trajectories-volumetric interpolated breath-hold examination [CDT-VIBE]). In this retrospective, institutional review board-approved study, 47 patients (median age, 62 years; 25 men, 22 women) scanned on a 3.0-T magnetic resonance system (Skyra; Siemens) were included. The CDT-VIBE (repetition time/echo time1/echo time2, 4.1/1.33/2.56 milliseconds; acquisition time, 29 seconds) was used in place of the standard arterial phase acquisition and started 15 seconds after the injection of 0.1 mmol/kg Gd-DOTA (Dotarem, Guerbet). Within 29 seconds, 14 high spatial resolution (1.2 × 1.2 × 3 mm) 3-dimensional data sets were acquired and reconstructed using view sharing (temporal resolution, 2.1 seconds). The CDT-VIBE images were evaluated independently by 2 blinded, experienced radiologists with regard to image quality and the number of hepatic arterial-dominant phases present on an ordinal 5-point scale (5, excellent; 1, nondiagnostic). Added diagnostic information with CDT-VIBE relative to portal venous phase VIBE was assessed. In all patients, CDT-VIBE measurements were successfully acquired. The image quality was diagnostic in 46 of the 47 patients. Both readers assessed the highest image quality present in the data sets with a median score of 4 (range, 3-5 for both readers; κ, 0.789) and the worst image quality with a median score of 3 (range, 1-4 for both readers; κ, 0.689). With a range between 1 and 8 (median, 5), hepatic arterial-dominant data sets (of the 14 acquired) were obtained in each case. There was an added diagnostic value with CDT-VIBE in 10 of the 47 patients (21%). The CDT-VIBE is a robust approach allowing, for the first time, dynamic imaging of the upper abdomen with high temporal resolution and preservation of high spatial resolution.

7 January 2017 in Chinese Journal of Cancer
Verified
Journal Article
Open access
PDF file
JHJinhua Huang
Jinhua Huang
JMJohn N. Morelli
John N. Morelli
FAFei Ai
Fei Ai
RZRu-Hai Zou
Ru-Hai Zou
YGYang-Kui Gu
Yang-Kui Gu
YZYan-Yang Zhang
Yan-Yang Zhang
A ruptured hepatocellular carcinoma (HCC) is often fatal. In addition to surgery and transarterial embolization, radiofrequency ablation (RFA) might be another option for treating a ruptured HCC. Unfortunately, conventional RFA has a limited ablation zone; as such, it is rarely used to treat ruptured tumors. This case was a 60-year-old man who had a large, ruptured HCC in which hydrochloric acid (HCl)-enhanced RFA successfully controlled the bleeding and made the tumor completely necrotic. Considering the effectiveness of HCl-enhanced RFA in achieving hemostasis and tumor ablation, it might be a new option for treating large, ruptured HCCs.

24 May 2013 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
JMJohn N. Morelli
John N. Morelli
CGClint M. Gerdes
Clint M. Gerdes
PSPeter Schmitt
Peter Schmitt
TATao Ai
Tao Ai
MSMegan R. Saettele
Megan R. Saettele
UAUlrike I. Attenberger
Ulrike I. Attenberger
As the complexity of the magnetic resonance angiography (MRA) techniques grows, it becomes more difficult for the practicing radiologist to appreciate the physical principles underlying these studies. Nevertheless, such an understanding is requisite for improving clinical image quality. As radiologists are most accustomed to dealing with medical images in everyday practice, it seems natural that an image-based approach to teaching MRA physics, rather than complex mathematical equations or pulse sequence diagrams, would be preferable. This article adopts such an approach. Simple ways to improve MRA image quality are emphasized along with new technologies and their physical basis. The ultimate goal of the article is to facilitate the practicing radiologist becoming more aware of the variety of MR techniques available, being more confident in modifying sequence parameters to improve image quality and reduce contrast dose, and understanding the basis behind newer MRA techniques. J. Magn. Reson. Imaging 2013;37:1326–1341.

1 January 2016 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
XLXiaoming Li
Xiaoming Li
JYJun Yang
Jun Yang
TZTianjing Zhang
Tianjing Zhang
JMJohn N. Morelli
John N. Morelli
SGShivraman Giri
Shivraman Giri
WTWenlin Tang
Wenlin Tang
The high incidence of renal insufficiency in patients with Peripheral Arterial Disease raises the concern for nephrogenic systemic fibrosis (NSF) with respect to contrast enhanced MRA. The risk of NSF is eliminated with non-contrast enhanced magnetic resonance angiography. The purpose of the current study is to compare image quality and diagnostic performance of non-contrast enhanced Quiescent Interval Single Shot (QISS) magnetic resonance angiography at 3 T versus CT angiography for evaluation of lower extremity Peripheral Arterial Disease (PAD). 32 consecutive patients (23 male, 9 female, age range 40–81 years, average age 61.97 years) with clinically suspected lower extremity PAD underwent QISS MRA and CTA. 19 of 32 patients underwent Digital Subtraction Angiography (DSA). Image quality of MRA was compared with CTA by two radiologists with 10 and 8 years’ experience according to a 4-point scale. The Kappa test was used to determine the intermodality agreement between MRA and CTA in stenosis assessment, and interobserver agreement with each method. Sensitivity and specificity of CTA and MRA in detecting hemodynamically significant stenosis (≥50 %) were compared, with DSA serving as reference standard when available. Image quality of QISS MRA was rated 3.70 ± 0.49 by reader 1, and 3.72 ± 0.47 by reader 2, significantly lower than that of CTA (3.80 ± 0.44 and 3.82 ± 0.42, P < 0.001 for both readers). Intermodality agreement between MRA and CTA was excellent for assessment of stenosis (Kappa = 0.923 ± 0.013 for reader 1, 0.930 ± 0.012 for reader 2). Interobserver agreement was 0.936 ± 0.012 for CTA and 0.935 ± 0.011 for MRA. For readers 1 and 2 respectively, the sensitivity of QISS was 94.25 and 93.26 % (versus 90.11 and 89.13 % for CTA, P > 0.05), and specificity of QISS was 96.70 and 97.75 % (versus 96.55 and 96.51 % for CTA, P > 0.05). For heavily calcified segments, sensitivity of QISS (95.83 and 95.83 %) was significantly higher than that of CTA (74.19 and 76.67 %, P < 0.05). QISS is a reliable alternative to CTA for evaluation of lower extremity PAD, and may be suitable as a first-line screening examination in patients with contraindications to intravenous contrast administration.

1 October 2016 in European Journal of Radiology
Verified
Journal Article
Closed access
YHYonglan He
Yonglan He
DHDaniel Hausmann
Daniel Hausmann
JMJohn N. Morelli
John N. Morelli
UAUlrike I. Attenberger
Ulrike I. Attenberger
SSStefan O. Schoenberg
Stefan O. Schoenberg
PRPhilipp Riffel
Philipp Riffel