8 November 2016 in Earthquake Engineering & Structural Dynamics
15 June 2017 in Earthquake Engineering & Structural Dynamics
16 February 2021 in Earthquake Engineering & Structural Dynamics
22 July 2016 in Structural Control and Health Monitoring
ASAndreas H. Schellenberg
A 2 m by 6 m unidirectional shake table was constructed at the University of California, Berkeley and combined with a real-time hybrid simulation system creating a hybrid shake table. A series of tests were carried out to examine the viability of real-time hybrid simulation techniques to perform experimental simulations of buildings with midlevel seismic isolation. The isolation system and superstructure were physically tested on the table while the portion of the building below the isolation plane was numerically modeled. OpenFresco was used to interface the numerical model with the control system. The isolated superstructure consisted of a two-story steel moment frame on six triple friction pendulum bearings, which exhibit significant nonlinear velocity-dependent behavior, necessitating real-time testing. Shear building models with a range of periods were used to represent the portion of the building below the isolation plane. Increasing the number of degrees of freedom increased the control difficulty as higher modes were excited in the numerical model because of experimental errors caused predominantly by feedback noise and table tracking. Nonetheless, the results illustrate that hybrid shake table tests are indeed an economical and reasonably accurate method to assess the seismic behavior of midlevel isolation systems installed in a range of building configurations. Results showed that midlevel isolation was beneficial for the superstructure and, to a smaller extent, the substructure. However, to achieve maximum benefits, it is recommended that the effective period of the isolation system be sufficiently longer than the period of the substructure. Copyright © 2016 John Wiley & Sons, Ltd.
19 November 2017 in Earthquake Engineering & Structural Dynamics
1 November 2018 in Journal of Structural Engineering
Base isolation is an effective method for mitigating seismic hazards and improving seismic performance under design-level ground motions. Previous studies have typically focused on comparing the performance of isolated and fixed-base buildings under design level or maximum considered level earthquakes without modeling the failure of the isolation bearings components. However, it is also important to include the performance of the isolation system under extreme conditions. A numerical model which explicitly includes both impact and uplift behavior of the sliding bearings as well as degrading behavior of the superstructure is used to investigate the collapse risk of the various friction pendulum isolated moment-resisting and concentrically braced frame designs. It is found that the stiffness of the superstructure has a large influence on the overall collapse risk. For flexible moment-resisting frames, increasing the strength is beneficial to improving the safety margin between impact and system-level failure. However, for stiff concentrically braced frames, because of their high stiffness, impact with the sliding bearing rim imposes a large ductility demand on the superstructure regardless of its strength, resulting in an unacceptable probability of collapse.