Liat Rosenfeld

Liat Rosenfeld

Auto-generated profile, based on publicly available information

Liat Rosenfeld

Department of Chemical and Materials Engineering, San José State University , San José, California 95192, USA

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2014 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
LRLiat Rosenfeld
Liat Rosenfeld
TLTiras Lin
Tiras Lin
RDRatmir Derda
Ratmir Derda
STSindy Tang
Sindy Tang

27 October 2014 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
MPMing Pan
Ming Pan
LRLiat Rosenfeld
Liat Rosenfeld
MKMinkyu Kim
Minkyu Kim
MXManqi Xu
Manqi Xu
ELEdith Lin
Edith Lin
STSindy K. Y. Tang
Sindy K. Y. Tang

1 April 2013 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
LRLiat Rosenfeld
Liat Rosenfeld
CCColin Cerretani
Colin Cerretani
DLDanielle L. Leiske
Danielle L. Leiske
MTMichael F. Toney
Michael F. Toney
CRClayton J. Radke
Clayton J. Radke
GFGerald G. Fuller
Gerald G. Fuller
Purpose. We explore the unique rheological and structural properties of human and bovine meibomian lipids to provide insight into the physical behavior of the human tear-film lipid layer (TFLL). Methods. Bulk rheological properties of pooled meibomian lipids were measured by a commercial stress-controlled rheometer; a home-built interfacial stress rheometer (ISR) probed the interfacial viscoelasticity of spread layers of meibomian lipids. Small- and wide-angle x-ray scattering detected the presence and melting of dispersed crystal structures. Microscope examination under cross polarizers provided confirmation of ordered crystals. A differential scanning calorimeter (DSC) analyzed phase transitions in bulk samples of bovine meibum. Results. Bulk and interfacial rheology measurements show that meibum is extremely viscous and highly elastic. It is also a non-Newtonian, shear-thinning fluid. Small- and wide-angle x-ray diffraction (SAXS and WAXS), as well as differential scanning calorimetry (DSC) and polarizing microscopy, confirm the presence of suspended lamellar-crystal structures at physiologic temperature. Conclusions. We studied meibum architecture and its relation to bulk and interfacial rheology. Bovine and human meibomian lipids exhibit similar physical properties. From all structural probes utilized, we find a melt transition near eye temperature at which lamellar crystals liquefy. Our proposed structure for the tear-film lipid layer at physiologic temperature is a highly viscoelastic, shear-thinning liquid suspension consisting of lipid lamellar-crystallite particulates immersed in a continuous liquid phase with no long-range order. When spread over on-eye tear, the TFLL is a duplex film that exhibits bulk liquid properties and two separate interfaces, air/lipid and water/lipid, with aqueous protein and surfactantlike lipids adsorbed at the water/lipid surface.

22 October 2013 in Soft Matter
Verified
Journal Article
Closed access
PDF file
LRLiat Rosenfeld
Liat Rosenfeld
LFLin Fan
Lin Fan
YCYunhan Chen
Yunhan Chen
RSRyan Swoboda
Ryan Swoboda
STSindy Tang
Sindy Tang
This paper describes the break-up of droplets in a concentrated emulsion during its flow as a 2D monolayer in a microchannel consisting of a narrow constriction. Analysis of the behavior of a large number of drops (N > 4000) shows that the number of break-ups increases with increasing flow rate, entrance angle to the constriction, and size of the drops relative to the width of the constriction. As single drops do not break at the highest flow rate used in the system, break-ups arise primarily from droplet–droplet interactions. Analysis of droplet properties at a high temporal resolution of 10 microseconds makes it possible to relate droplet deformation with droplet break-up probability. Similar to previous studies on single drops, no break-up is observed below a set of critical flow rates and droplet deformations. Unlike previous studies, however, not all drops undergo break-up above the critical values. Instead, the probability of droplet break-up increases with flow rate and the deformation of the drops. The probabilistic nature of the break-up process arises from the stochastic variations in the packing configuration of the drops as they enter the constriction. Local break-up dynamics involves two primary drops. A close look at the interactions between the pair of drops reveals that the competing time scales of droplet rearrangement relative to the relaxation of the opposing drop govern whether break-up occurs or not. Practically, these results can be used to calculate the maximum throughput of the serial interrogation process often employed in droplet microfluidics. For 40 pL-drops, the highest throughput with less than 1% droplet break-up was measured to be approximately 7000 drops per second. In addition, the results presented are useful for understanding the behavior of concentrated emulsions in applications such as mobility control in enhanced oil recovery, and for extrapolating critical parameters such as injection rates to ensure the stability of the fluids going through small pore throats.

1 August 2012 in Langmuir
Verified
Journal Article
Closed access
DLDanielle L. Leiske
Danielle L. Leiske
CMChad E. Miller
Chad E. Miller
LRLiat Rosenfeld
Liat Rosenfeld
CCColin Cerretani
Colin Cerretani
AAAlexander Ayzner
Alexander Ayzner
GFGerald G. Fuller
Gerald G. Fuller

28 September 2012 in Langmuir
Verified
Journal Article
Closed access
LRLiat Rosenfeld
Liat Rosenfeld
GFGerald G. Fuller
Gerald G. Fuller