The particulars of dc current passage through a structure consisting of a doubly connected superconductor (DCS) with branches that are asymmetric with respect to length and critical current have been investigated experimentally. The short branch, which has the lowest critical current, was a clamping niobium-niobium point contact with length comparable to the coherence length of the superconductor. In contrast to a previously studied DCS with a short branch much longer than the coherence length, it was found that when the short-branch current reaches the critical value the currents in the branches of the DCS do not undergo self-excited oscillations; a current exceeding the critical value enters the long branch when this current is increased in portions (is quantized), and when it is subsequently decreased it freezes partially or completely in the DCS circuit.
28 March 2021 in Innovative technologies and scientific solutions for industries
The subject of the study in the article is to study the method of excitation of human body tissues using an electric current. The purpose of the work is to develop a method for exciting local current in a human body affecting the microcirculation of blood and excitability of local areas of muscle tissue during the treatment process. The article solves the following tasks: the creation of a model pattern of fabric, the rationale for the generation of electric current inside the sample, the development of the design of the current generation system and measuring the electrical response of the model sample of the tissue on the occurrence of electric current, determining the size and spatial current distribution in the model sample of the fabric, comparison The obtained current values with known and admissible in medical practice its values, determination of the advantages of the proposed method of excitation of current compared to the traditional used in medicine. The following methods were used: analysis of scientific publications for the subject of the study, the calculation of the expected current parameters in the model sample, the method of designing the nodes of the current generation and measurement system of the electrical response, the experimental method of excitation of the current and measuring the sample response to it. The following results were obtained: a new acoustic-magnetic method of exciting electric current in local areas of muscle tissue is justified, which allows determining for them the optimal values of the therapeutic current and the value of its threshold value. model samples of muscle tissue are created, a magnetohydrodynamic method of generating electric current inside the patient's body is justified, design of a system for generating current and measuring the electrical response of a model fabric sample to the occurrence of electric current in it; determining the magnitude and spatial distribution of the current in the model fabric sample; comparison of obtained current values with known and permissible values in medical practice and proved their safety for a person. Calculated ratios are obtained, which connect value of excited local current with parameters of ultrasonic radiation, external permanent magnetic field and biological medium. The materials have been found that the current density excited in the local area of the biological medium is independent of the ultrasound frequency and is determined mainly by the intensity of the ultrasound and the constant magnetic field. The advantages of the current excitation method according to the present invention over the conventional galvanic method of passing current through the patient's skin are the ability to generate current in any desired local area of the patient's tissue and its complete safety. Conclusions: The scientific foundations of the new method of excitation of local current inside the human body have been developed and experimentally tested on model samples. Using this method can significantly increase the effectiveness of the treatment process based on the effect of current on blood microcirculation in predetermined areas of muscle tissue and for the first time will allow distinguishing and determining with high accuracy thresholds of their excitability by electric current.
The subject of study in the article is the acoustic resistance of local areas of the biological tissues in vivo, depending on their pathology. The aim of the work is to develop a quantitative method for measuring the acoustic resistance of local areas of the biological tissue (substance) located inside the human body. The following tasks are solved in the article: development of scientific foundations of the acousto-magnetic method for measuring the acoustic resistance of local areas of the biological tissue; development of a remote method for measuring electrical voltage on the surface of the patient's skin, caused by acousto-magnetic impact on local areas of the tissue and determined by the value of acoustic resistance; calculation of the ratios binding the value of the acoustic resistance of the local areas of the tissue with the electric voltage on the measuring probes on the patient's skin, the values of the acoustic radiation power and the external constant magnetic field, as well as with the distance between the probes and the local area of the biological tissue; verification of the calculated ratios using the experimental determination of the acoustic resistance of the local area of the model biological tissue. The following methods were used: physical modeling of the biological tissue, physical and mathematical modeling of electrical properties of the local part of the biological tissue, calculation of electromagnetic and acoustic parameters of the tissue, experimental measurement of electric field strength excited in the local part of the biological tissue, verification of calculated relations by comparing them with experimental results. The following results were obtained: the scientific foundations of the acousto-magnetic method for the quantitative measurement of the acoustic resistance of local areas of the biological tissue were developed; a remote method for measuring the electric voltage on the surface of the patient's skin caused by the acousto-magnetic effect on local areas of the tissue and the determined value of the acoustic impedance was developed; relations were calculated connecting the value of the acoustic impedance of local areas of the tissue with the electric voltage on the measuring probes on the patient's skin, the values of the acoustic radiation power and external constant magnetic field, as well as the distance between the probes and the local area of the biological tissue; verification of the calculated ratios was carried out using the experimental determination of the acoustic resistance of the local area of the model biological tissue. Conclusions: The scientific foundations of the remote acousto-magnetic method of high-precision measurement of the acoustic resistance of local areas of human biological tissue, confirmed experimentally on model tissue samples, have been developed. The method can make it possible to reveal with high accuracy the functional relations of the measured local value of acoustic resistance with pathological changes in the tissue. At the same time, the influence of the human factor on the interpretation of the recorded values of acoustic resistance (which is characteristic of the traditional, mainly qualitative, rather than quantitative ultrasound method) is excluded, the information content and reliability of acoustic diagnostics are increased.
1 January 2019 in Telecommunications and Radio Engineering
The technique and results of experiments on the registration of magnetic nanoparticles in a colloidal solution using the combined effect of ultrasound and a direct magnetic field are presented. The possibility of using this technique to control the content of magnetic nanoparticles in a biological substance is discussed.
The safety of nanoparticles used in medical cosmetology and dermatology raises significant concerns. One of the tasks of analyzing the concentration of nanoparticles that must be solved for the practical analysis of the quality of products with nanoparticles is the quantitative analysis of the content of nanoparticles. The previously developed acousto-magnetic method (AMM) for determining the concentration of APIs as magnetic nanoparticles can be used to determine the nanoparticles' concentration when samples are prepared as a colloidal solution. It is shown that the described method not only can be applied for quality control in cosmetology and dermatology but also can be simplified by using a less sensitive magnetometer, which makes this direct method more available in the entire range of values of the concentration of magnetic nanoparticles used in medical cosmetology and dermatology.