Meng Liu

Meng Liu

Auto-generated profile, based on publicly available information

Meng Liu

State Key Laboratory of Advanced Optical Communication Systems and Networks, School of Electronics, and Center for Quantum Information Technology, Peking University, Beijing 100871, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2023 in Science Advances
Verified
Journal Article
Closed access
WXWei Xiao
Wei Xiao
CSChenxi Sun
Chenxi Sun
LSLiang Shen
Liang Shen
YFYulong Feng
Yulong Feng
MLMeng Liu
Meng Liu
HGHong Guo
Hong Guo
Magnetocardiography (MCG), which uses high-sensitivity magnetometers to record magnetic field signals generated by electrical activity in the heart, is a noninvasive method for evaluating heart diseases such as arrhythmia and ischemia. The MCG measurements usually require the participant keeping still in a magnetically shielded room due to the immovable sensor and noisy external environments. These requirements limit MCG applications, such as exercise MCG tests and long-term MCG observations, which are useful for early detections of heart diseases. Here, we introduce a movable MCG system that can clearly record MCG signals of freely behaving participants in an unshielded environment. On the basis of optically pumped magnetometers with a sensitivity of 140 fT/Hz1/2, we successfully demonstrated the resting MCG and the exercise MCG tests. Our method is promising to realize a practical movable multichannel unshielded MCG system that nearly sets no limits to participants and brings another kind of insight into the medical diagnosis of heart disease.

4 April 2023 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
WXWei Xiao
Wei Xiao
MLMeng Liu
Meng Liu
TWTeng Wu
Teng Wu
XPXiang Peng
Xiang Peng
HGHong Guo
Hong Guo
Searching for beyond-the-standard-model interactions has been of interest in quantum sensing. Here, we demonstrate a method, both theoretically and experimentally, to search for the spin- and velocity-dependent interaction with an atomic magnetometer at the centimeter scale. By probing the diffused optically polarized atoms, undesirable effects coming along with the optical pumping, such as light shifts and power-broadening effects, are suppressed, which enables a 1.4  fTrms/Hz1/2 noise floor and the reduced systematic errors of the atomic magnetometer. Our method sets the most stringent laboratory experiment constraints on the coupling strength between electrons and nucleons for the force range λ>0.7  mm at 1σ confidence. The limit is more than 3 orders of magnitude tighter than the previous constraints for the force range between 1  mm∼10  mm, and one order of magnitude tighter for the force range above 10 mm.