25 November 2020 in Journal of Neurophysiology
Sensorimotor adaptation is influenced by both the size and variance of error information. In the present study, we varied visual uncertainty and error size in a factorial manner and evaluated their joint effect on adaptation, using a feedback method that avoids inherent limitations with standard visuomotor tasks. Uncertainty attenuated adaptation but only when the error was small. This striking interaction highlights a novel constraint for models of sensorimotor adaptation.
8 July 2020 in Proceedings Of The Royal Society B-Biological Sciences
Perceiving the positions of objects is a prerequisite for most other visual and visuomotor functions, but human perception of object position varies from one individual to the next. The source of these individual differences in perceived position and their perceptual consequences are unknown. Here, we tested whether idiosyncratic biases in the underlying representation of visual space propagate across different levels of visual processing. In Experiment 1, using a position matching task, we found stable, observer-specific compressions and expansions within local regions throughout the visual field. We then measured Vernier acuity (Experiment 2) and perceived size of objects (Experiment 3) across the visual field and found that individualized spatial distortions were closely associated with variations in both visual acuity and apparent object size. Our results reveal idiosyncratic biases in perceived position and size, originating from a heterogeneous spatial resolution that carries across the visual hierarchy.
19 December 2022 in Frontiers in Psychology
Introduction: Radiologists routinely make life-altering decisions. Optimizing these decisions has been an important goal for many years and has prompted a great deal of research on the basic perceptual mechanisms that underlie radiologists’ decisions. Previous studies have found that there are substantial individual differences in radiologists’ diagnostic performance (e.g., sensitivity) due to experience, training, or search strategies. In addition to variations in sensitivity, however, another possibility is that radiologists might have perceptual biases—systematic misperceptions of visual stimuli. Although a great deal of research has investigated radiologist sensitivity, very little has explored the presence of perceptual biases or the individual differences in these.Methods: Here, we test whether radiologists’ have perceptual biases using controlled artificial and Generative Adversarial Networks-generated realistic medical images. In Experiment 1, observers adjusted the appearance of simulated tumors to match the previously shown targets. In Experiment 2, observers were shown with a mix of real and GAN-generated CT lesion images and they rated the realness of each image.Results: We show that every tested individual radiologist was characterized by unique and systematic perceptual biases; these perceptual biases cannot be simply explained by attentional differences, and they can be observed in different imaging modalities and task settings, suggesting that idiosyncratic biases in medical image perception may widely exist.Discussion: Characterizing and understanding these biases could be important for many practical settings such as training, pairing readers, and career selection for radiologists. These results may have consequential implications for many other fields as well, where individual observers are the linchpins for life-altering perceptual decisions.
6 September 2019 in Journal of Vision
Accurately perceiving the positions of objects is a critical visual function. Recent research demonstrated that observers consistently mislocalize brief objects throughout the visual field in an idiosyncratic manner: observes mislocalize objects in different ways in different parts of the visual field (Kosovicheva & Whitney, 2017). One possibility is that these fingerprints of distorted space perception are related to differences in the resolution of position coding throughout the visual field. If so, there may be systematic differences in acuity throughout the visual field that correlate with the mislocalizations. Here, we tested this. In a first experiment, we constructed localization bias maps throughout the visual field for individual observers. Observers were asked to localize a brief noise patch target with a mouse cursor. The possible target locations covered much of the visual field. Mislocalization (constant) errors were recorded and found to be significant and idiosyncratic, such that each observer mislocalized targets consistently in a unique way throughout the visual field. Because of the mislocalizations, there were some regions of the visual field that were effectively compressed (sinks) and other regions that were expanded (sources). In a second experiment, we tested whether these individualized perceptual distortion maps correlated with differences in visual resolution. We tested Vernier acuity thresholds at 6 locations in each observer’s visual field, specifically 4 in the compressed and expanded regions identified in the first Experiment and 2 in neutral regions. Interestingly, we found significantly higher acuity in perceptually compressed regions than in the expanded regions. The results reveal a primitive inhomogeneity in the spatial resolution of position coding, which may then bias assigned object position. This inhomogeneity indicates that our visual system evidently has a compensatory mechanism to correct the individualized biases, to establish an accurate and stable position representation that is ultimately consistent between observers.