Nasreen Mohsin

Nasreen Mohsin

Auto-generated profile, based on publicly available information

Nasreen Mohsin

Networked Robotics and Sensing Laboratory, School of Engineering Science, Simon Fraser University, Burnaby, British Columbia, V5A 1S6, Canada

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2019 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
NMNasreen Mohsin
Nasreen Mohsin
Shahram PayandehShahram Payandeh
Shahram Payandeh
DHDerek Ho
Derek Ho
JGJean Pierre Gelinas
Jean Pierre Gelinas
This paper proposes a proof-of-concept, low-cost, and easily deployable Bluetooth low energy- (BLE-) based localization system which actively scans and localizes BLE beacons attached to mobile subjects in a room. Using the received signal strength (RSS) of a BLE signal and the uniqueness of BLE hardware addresses, mobile subjects can be identified and localized within the hospital room. The RSS measurement of the BLE signal from a wearable BLE beacon varies with distance to the wall-anchored BLE scanner. In order to understand and demonstrate the practicality of the relationship between RSS of a BLE beacon and the distance of a beacon from a scanner, the first part of the paper presents the analysis of the experiments conducted in a low-noise and nonreflective environment. Based on the analysis conducted in an ideal environment, the second half of the paper proposes a data-driven localization process for pinpointing the movements of the subject within the experimental room. In order to ensure higher accuracy like fingerprinting techniques and handle the increased number of BLE-anchored scanners like geometric techniques, the proposed algorithm was designed to combine the best aspects of these two techniques for better localization. The paper evaluates the effects of the number of BLE wall-mounted scanners and the number of packets on the performance of the proposed algorithm. The proposed algorithm locates the patient within the room with error less than 1.8 m. It also performs better than other classical approaches used in localization.

1 March 2015
Verified
Conference Paper
Closed access
KHKarel Heurtefeux
Karel Heurtefeux
OEOchirkhand Erdene-Ochir
Ochirkhand Erdene-Ochir
NMNasreen Mohsin
Nasreen Mohsin
HMHamid Menouar
Hamid Menouar
To gather and transmit data, low cost wireless devices are often deployed in open, unattended and possibly hostile environment, making them particularly vulnerable to physical attacks. Resilience is needed to mitigate such inherent vulnerabilities and risks related to security and reliability. In this paper, Routing Protocol for Low-Power and Lossy Networks (RPL) is studied in presence of packet dropping malicious compromised nodes. Random behavior and data replication have been introduced to RPL to enhance its resilience against such insider attacks. The classical RPL and its resilient variants have been analyzed through Cooja simulations and hardware emulation. Resilient techniques introduced to RPL have enhanced significantly the resilience against attacks providing route diversification to exploit the redundant topology created by wireless communications. In particular, the proposed resilient RPL exhibits better performance in terms of delivery ratio (up to 40%), fairness and connectivity while staying energy efficient.

1 February 2014
Verified
Conference Paper
Closed access
JGJesus Efrain Gaxiola-Sosa
Jesus Efrain Gaxiola-Sosa
NMNasreen Mohsin
Nasreen Mohsin
APAbdul J. Palliyali
Abdul J. Palliyali
RTReza Tafreshi
Reza Tafreshi
KEKamran Entesari
Kamran Entesari
This paper presents a 12-lead electrocardiogram (ECG) wireless medical system (WMS) aimed to provide continuous patient monitoring. The WMS consists of three sections: end device (ED), base station (BS) and graphical user interface (GUI). The ED and BS communicate through an RF link that operates in the industrial, scientific and medical (ISM) band at 2.45 GHz. The ED is based on commercially-available ultra-low power integrated circuits, including an 8 channel analog front-end (AFE) intended for biopotential monitoring, a microcontroller unit and an ISM radio transceiver. Details on the 12-lead ECG WMS operation including the low-power oriented control algorithm of the ED and the detection algorithm embedded in the GUI are presented. Measurements of the WMS using a 10 electrode ECG signal generator show successful communication up to 35m line of sight. The ED average current consumption is 33mA (including RF transmission) in continuous operation. This allows the ED to operate up to 88 hours.

17 November 2016
Verified
Conference Paper
Closed access
NMNasreen Mohsin
Nasreen Mohsin
XLXuhong Liu
Xuhong Liu
SPShahram Payandeh
Shahram Payandeh
Several efforts are being made in studying sleeping posture of a person under natural conditions without causing discomfort. In this study, various methods are proposed and explored in which features defining sleep postures of a person are investigated for intelligent pattern recognition. Using the measured depth data, three dimensional depth scans as well as the cross-sectional scans of the static sleeping body are captured. 1D Fast Fourier Transforms are used as complementary feature of the cross-sectional scans in pattern recognition. Due to better orientation-frequency characteristics, the two dimensional Gabor filter banks are also applied on depth images to produce Gabor images from which features known as Gabor features can be extracted. These selected features can be further integrated as a part of natural sleep posture recognition.


1 October 2017
Verified
Conference Paper
Closed access
NMNasreen Mohsin
Nasreen Mohsin
SPShahram Payandeh
Shahram Payandeh
This paper explores the novel use of multiple depth sensors to overcome occlusions and improve localization and tracking of body extremities. The usage of data from only depth sensors not only overcomes visual challenges associated with RGB sensors under low illumination, but also protects the identity of surveyed person with high confidentiality. For integrating depth information from multiple sources, the paper presents first an overview of a novel calibration method for multiple depth sensors. In case of occlusion of any fiducial point in the primary sensor's depth image, co-ordinates of the point can be obtained from the frame of other sensors using the calibration parameters. To localize salient body parts such as hands, head and feet, a surface triangular mesh is applied on generated 3D point cloud from the primary sensor. The geodesic extrema from the mesh coincide with body extremities. The body extremities can be identified based on those relative geodesic distances between the extremities. Once the body parts are labelled, a portion of body can be targeted and evaluated for specific gait analysis and visualization. For the performance evaluation, our calibration method has fared well in comparison to other available techniques. Also, our proposed localization of salient body parts is able to successfully tag the specific body part i.e. the head region.