Puvan Arumugam

Puvan Arumugam

Auto-generated profile, based on publicly available information

Puvan Arumugam

University of Nottingham, Nottingham, U.K.

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2018 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
SBSerhiy Bozhko
Serhiy Bozhko
TYTao Yang
Tao Yang
JPJean-Marc Le Peuvedic
Jean-Marc Le Peuvedic
PAPuvan Arumugam
Puvan Arumugam
MDMarco Degano
Marco Degano
Patrick WheelerPatrick Wheeler
Patrick Wheeler
More-electric aircraft (MEA) has become a dominant trend for modern aircraft. On-board MEA, many functions, which are conventionally driven by pneumatic and hydraulic power, are replaced with electrical subsystems. Starting aircraft engines with an electrical motor instead of using pneumatic power from the auxiliary power unit (APU) is one of the major characteristics of future aircraft. This paper presents the development of a novel electric starter-generator system for aircraft applications. The paper describes the main achievements of the project within the key areas including electric machines, power electronic converters, thermal management and overall system control design. The developed prototype has been tested successfully and the test results are presented in this paper.

16 March 2012 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
PAPuvan Arumugam
Puvan Arumugam
THTahar Hamiti
Tahar Hamiti
CGChristopher Gerada
Christopher Gerada
This paper describes an analytical model to evaluate the short-circuit (SC) current resulting from an interturn fault by computing the self and mutual inductances under SC fault condition. Two different concentrated winding configurations, i.e., horizontally and vertically placed conductors in the slot of a fault-tolerant permanent magnet synchronous machine are considered. By computing the associated slot-leakage and air-gap fluxes, the self inductance of both healthy and faulty windings as well as the mutual inductance between them, the SC current can be determined for any position and number of shorted turns. The proposed model is verified with finite-element analysis and validated experimentally. It will be shown that the magnitude of an interturn SC current depends on both the number of shorted turns and their position in the slot. The measured SC inductance shows that a new proposed concentrated vertical winding configuration can inherently limit the SC current and reduce its dependence on the position within the slot.

24 April 2013 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
PAPuvan Arumugam
Puvan Arumugam
THTahar Hamiti
Tahar Hamiti
CBChristopher Brunson
Christopher Brunson
CGChristopher Gerada
Christopher Gerada
This paper investigates the behavior of a vector-controlled fault-tolerant permanent magnet motor drive system adopting a vertically placed strip winding (VSW) which can limit interturn short-circuit (SC) fault current to its rated value regardless of the position in the slot containing the shorted turns. The drives' dynamic behavior is simulated using a per-phase equivalent circuit model, with the winding inductances and resistances analytically calculated based on the machine geometry and fault location. A simplified thermal model is also grafted into the system model to effectively simulate the dynamic behavior of the machine during healthy interturn SC fault and postfault controlled scenarios. The SC-fault-current-limiting capability, the additional losses, and the thermal behavior of the winding are studied and compared with conventional winding adopting round conductor winding. The proposed winding design is verified with finite-element analysis and is then validated experimentally. Results show that the VSW inherently limits the SC current, reduces its dependence on the position of the fault within the slot, but results in an increase in ac losses.

17 November 2015 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
JDJiri Dusek
Jiri Dusek
PAPuvan Arumugam
Puvan Arumugam
CBChristopher Brunson
Christopher Brunson
EAEmmanuel K. Amankwah
Emmanuel K. Amankwah
THTahar Hamiti
Tahar Hamiti
CGChristopher Gerada
Christopher Gerada
This paper investigates the influence of the slot/pole (S/P) combination on inter-turn short-circuit (SC) current in fault-tolerant permanent magnet (FT-PM) machines. A 2-D sub-domain field computational model with multi-objective genetic algorithm is used for the design and performance prediction of the considered FT-PM machines. The electromagnetic losses of machines, including iron, magnet, and winding losses are systematically computed using analytical tools. During the postprocessing stage, a 1-D analysis is employed for turn-turn fault analysis. The method calculates self- and mutual inductances of both the faulty and healthy turns under an SC fault condition with respect to the fault locations, and thus SC fault current, considering its location. Eight FT-PM machines with different S/P combinations are analyzed. Both the performance of the machine during normal operation and induced currents during a turn-turn SC fault are investigated. To evaluate the thermal impact of each S/P combination under an inter-turn fault condition, a thermal analysis is performed using finite element computation. It is shown that low-rotor-pole-number machines have a better fault tolerance capability, while high-rotor-pole-number machines are lighter and provide higher efficiency. Results show that the influence of the S/P selection on inter-turn fault SC current needs to be considered during the design process to balance the efficiency and power density against fault-tolerant criteria of the application at hand.

30 April 2013 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
PAPuvan Arumugam
Puvan Arumugam
THTahar Hamiti
Tahar Hamiti
CGChristopher Gerada
Christopher Gerada
This paper presents an analytical methodology based on subdomain field model to calculate eddy current loss in vertical conductor windings (VCWs) of surface mounted, radial flux, permanent magnet (PM) machines considering the current penetration effect. The proposed model can be used with any slot-pole combination including fractional slot machines having VCW. Initially, the model solves the two-dimensional problem based on the Laplace's and Poisson's equations using the separation of variables technique for each of the subdomains: PM, airgap, slot opening, and slot. Then, based on that obtained solution, the eddy current reaction field in the slot is calculated by solving complex Helmholtz's equation. The validity and accuracy of the model is verified using finite-element (FE) analysis. The limitations of analytical method are discussed.

1 November 2015 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
PAPuvan Arumugam
Puvan Arumugam
THTahar Hamiti
Tahar Hamiti
CGChristopher Gerada
Christopher Gerada
This study presents a systematic study on turn–turn short circuit (SC) fault and ways to manage them to provide a basis for comparison of the various options available. The possible methods to reduce the likelihood of the winding SC fault and the fault mitigation techniques related to such faults are discussed. A finite‐element analysis of a surface‐mounted permanent magnet machine under application of different mitigation techniques during a turn–turn fault is presented. Both machine and drive structural adaptations for different fault mitigation techniques are addressed. Amongst the investigated fault mitigation techniques, the most promising solution is identified and validated experimentally. It is shown that the shorting terminal method adopting vertical winding arrangement is an effective method in terms of the implementation, reliability and weight.