Jiahao Zheng

Jiahao Zheng

Auto-generated profile, based on publicly available information

Jiahao Zheng

School of Internet of Things, Nanjing University of Posts and Telecommunications 1 , Nanjing 210000

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

6 July 2026 in Applied Physics Letters
Verified
Journal Article
Closed access
JZJiahao Zheng
Jiahao Zheng
SLShu Liu
Shu Liu
WWWeizhou Wu
Weizhou Wu
JWJinxu Wang
Jinxu Wang
JGJunchi Gao
Junchi Gao
GDGuanxiang Du
Guanxiang Du
Nitrogen-vacancy centers in diamond enable microwave-free optical thermometry, but conventional zero-phonon-line readout becomes unreliable at elevated temperature and low signal-to-noise ratios because the local spectral signature progressively weakens into the background. Here, we infer temperature from the thermodynamic evolution of the phonon sideband (PSB) across a broad spectral window. A physics-aware decomposition separates a curvature-preserving PSB trend, which retains thermally driven broadening and redshift, from an ultra-smooth baseline that captures device-dependent background drift. These descriptors form a five-channel input to a one-dimensional dilated residual network with coarse-to-fine regression, shifting temperature inference from fragile local peak tracking to robust global trend learning. In the enhanced-inference noise-stress diagnostic, the selected σtrain=0.04 configuration gives the best clean-test mean absolute error (MAE) of 0.21 K,while the full σtrain sweep characterizes the trade-off between clean-condition accuracy and severe-noise robustness. A strict exact-match single-pass benchmark, disabling inference-time enhancement and post-hoc calibration, gives a five-channel ResNet MAE of 0.6792 K and confirms that the gain arises from the physics-aware representation–backbone combination rather than from inference enhancement alone. Beyond the in-domain benchmark, the pretrained representation also supports lightweight target-domain transfer: on a related sample batch over a narrower 20–60 °C interval, few-step continuation reduces the all-sample diagnostic MAE from 0.484K to 0.045 K. This transfer result demonstrates efficient target-domain refinement, but is reported separately from the main in-domain benchmark owing to the different temperature interval and sample domain. These results establish PSB-wide physics-aware trend learning as a robust route for microwave-free diamond thermometry and practical raster-scanned thermal mapping.