1 January 2010 in Brazilian Dental Journal
This study ascertained whether under dental erosion models that closely mimics the real-life situation enamel and root dentin from bovine origin would be reliable substitutes for human counterparts. Through a 2x2 crossover design, in a first trial, 14 volunteers wore a palatal device containing slabs of bovine and human enamel. Half of the participants ingested (4x daily, for 10 days) orange juice first, crossing over to mineral water, while the remainder received the reverse sequence. In a second trial, volunteers wore devices with slabs of bovine and human root dentin. Except for the duration of each intraoral phase, which lasted 2 rather 10 days, the experiment with root dentin run exactly as for enamel. Dental substrates were analyzed for surface microhardness. Two-way ANOVAs (α=0.05) indicated no difference between the microhardness values recorded for human and bovine enamel (p=0.1350), but bovine root dentin had lower microhardness compared to its human counterpart (p=0.0432). While bovine enamel can reliably substitute its human counterpart in in situ dental erosion models, bovine root dentin does not seem to be a viable alternative to the corresponding human tissue.
14 May 2004 in Clinical Oral Investigations
1 June 2009 in Brazilian Oral Research
Dental erosion is a type of wear caused by non bacterial acids or chelation. There is evidence of a significant increase in the prevalence of dental wear in the deciduous and permanent teeth as a consequence of the frequent intake of acidic foods and drinks, or due to gastric acid which may reach the oral cavity following reflux or vomiting episodes. The presence of acids is a prerequisite for dental erosion, but the erosive wear is complex and depends on the interaction of biological, chemical and behavioral factors. Even though erosion may be defined or described as an isolated process, in clinical situations other wear phenomena are expected to occur concomitantly, such as abrasive wear (which occurs, e.g, due to tooth brushing or mastication). In order to control dental loss due to erosive wear it is crucial to take into account its multifactorial nature, which predisposes some individuals to the condition
1 January 2011 in Brazilian Dental Journal
LVLilian Oliveira Cambaúva Vitussi
Lilian Oliveira Cambaúva Vitussi
This study assessed the effect of bleaching protocols with 38% hydrogen peroxide (HP) and post-bleaching times on shear bond strength of a composite resin to dentin. One-hundred slabs of intracoronary dentin were included and randomly assigned into 2 groups according to the bleaching protocol: HP (2 applications of 10 min each) and HP activated by LED laser (2 applications of 10 min each/45 s of light activation). Groups were subdivided according to the post-bleaching time (n=10): 1 day, 3 days, 7 days, 10 days and 14 days. The control group was unbleached and restored (n=10). The specimens were restored with Single Bond adhesive system/Filtek Z250 resin using a polytetrafluorethylene matrix and were submitted to the shear bond strength testa after 24 h,. Data were analyzed by ANOVA and Tukey's test (α=0.05). Unbleached group (0.283 ± 0.134) had the highest bond strength and was statistically similar (p>0.05) to HP/10 days (0.278 ± 0.064), HP + LED laser/10 days (0.280 ± 0.078), HP/14 days (0.281 ± 0.104), HP + LED laser/14 days (0.277 ± 0.093). Lower bond strength were verified in HP/1 day (0.082 ± 0.012), HP/3 days (0.079 ± 0.013), HP + LED laser/1 day (0.073 ± 0.018) and HP + LED laser/3 days (0.080 ± 0.015), which were statistically similar (p>0.05). HP/7 days (0.184 ± 0.154) and HP + LED laser/7 days (0.169 ± 0.102) had intermediate values (p
17 November 2011 in Dental Traumatology
YSYara Terezinha Correa Silva‐Sousa
Yara Terezinha Correa Silva‐Sousa
ASAline Evangelista Souza‐Gabriel
Aline Evangelista Souza‐Gabriel
1 January 2011 in Brazilian Dental Journal
MFMaria Isabel Anastácio Faria
Maria Isabel Anastácio Faria
ASAline Evangelista Souza-Gabriel
Aline Evangelista Souza-Gabriel
This study evaluated the effect of 980-nm diode laser on apical microleakage and intraradicular dentin morphology. Roots of 110 mandibular incisors were used in the study: 92 for microleakage test and 18 for scanning electron microscopy (SEM). Roots were randomly assigned to 3 groups according to the irrigating solution (water, NaOCl and NaOCl/EDTA) and were divided into 3 subgroups according to the laser irradiation protocol (without irradiation, irradiated at 1.5 W and irradiated at 3.0 W). Two specimens of each subgroup were prepared for SEM. The remaining roots were filled with AH Plus and gutta-percha. Apical leakage was assessed by ink penetration and data were analyzed statistically by ANOVA and Tukey-Krammer test (α=0.05). SEM analysis showed intensification of changes with increase of laser power as well as variations according to the irrigating solution. Modified smear layer was observed in specimens treated with water and irradiated with laser. Roots irrigated with NaOCl/EDTA had lower levels of infiltration (0.17 ± 0.18 mm) differing significantly (p0.05) to those irrigated with NaOCl (0.28 ± 0.29 mm). Non-irradiated roots had lower levels of infiltration (0.10 ± 0.14 mm), differing (p<0.05) from those irradiated at 1.5 W (0.32 ± 0.22 mm) and 3.0 W (0.37 ± 0.32 mm). The 980 nm diode laser modified dentin morphology and increased apical microleakage.