13 December 2004 in Physical Review Letters
We introduce a new, highly sensitive, and simple heterodyne optical method for imaging individual nonfluorescent nanoclusters and nanocrystals. A 2 order of magnitude improvement of the signal is achieved compared to previous methods. This allows for the unprecedented detection of individual small absorptive objects such as metallic clusters (of 67 atoms) or nonluminescent semiconductor nanocrystals. The measured signals are in agreement with a calculation based on the scattering field theory from a photothermal-induced modulated index of refraction profile around the nanoparticle.
20 January 2006 in Physical Review B
We present the theoretical and detailed experimental characterizations of photothermal heterodyne imaging. An analytical expression of the photothermal heterodyne signal is derived using the theory of light scattering from a fluctuating medium. The amplitudes of the signals detected in the backward and forward configurations are compared and their frequency dependences are studied. The application of the photothermal heterodyne detection technique to the absorption spectroscopy of individual gold nanoparticles is discussed and the detection of small individual silver nanoparticles is demonstrated.
1 December 2006 in Biophysical Journal
1 May 2001 in Biophysical Journal
The spectral and photophysical characteristics of the autofluorescent proteins were analyzed and compared to flavinoids to test their applicability for single-molecule microscopy in live cells. We compare 1) the number of photons emitted by individual autofluorescent proteins in artificial and in vivo situations, 2) the saturation intensities of the various autofluorescent proteins, and 3) the maximal emitted photons from individual fluorophores in order to specify their use for repetitive imaging and dynamical analysis. It is found that under relevant conditions and for millisecond integration periods, the autofluorescent proteins have photon emission rates of ∼3000 photons/ms (with the exception of DsRed), saturation intensities from 6 to 50kW/cm2, and photobleaching yields from 10−4 to 10−5. Definition of a detection ratio led to the conclusion that the yellow-fluorescent protein mutant eYFP is superior compared to all the fluorescent proteins for single-molecule studies in vivo. This finding was subsequently used for demonstration of the applicability of eYFP in biophysical research. From tracking the lateral and rotational diffusion of eYFP in artificial material, and when bound to membranes of live cells, eYFP is found to dynamically track the entity to which it is anchored.
1 November 2001 in Biophysical Journal
1 January 2004 in Biophysical Journal