Elton Ho

Elton Ho

Auto-generated profile, based on publicly available information

Elton Ho

Hansen Experimental Physics Laboratory, Stanford University, Stanford, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2022 in Nature Communications
Verified
Journal Article
Open access
PDF file
BWBing-Yi Wang
Bing-Yi Wang
ZCZhijie Charles Chen
Zhijie Charles Chen
MBMohajeet Bhuckory
Mohajeet Bhuckory
THTiffany Huang
Tiffany Huang
ASAndrew Shin
Andrew Shin
DPDaniel Palanker
Daniel Palanker
Localized stimulation of the inner retinal neurons for high-acuity prosthetic vision requires small pixels and minimal crosstalk from the neighboring electrodes. Local return electrodes within each pixel limit the crosstalk, but they over-constrain the electric field, thus precluding the efficient stimulation with subretinal pixels smaller than 55 μm. Here we demonstrate a high-resolution prosthetic vision based on a novel design of a photovoltaic array, where field confinement is achieved dynamically, leveraging the adjustable conductivity of the diodes under forward bias to turn the designated pixels into transient returns. We validated the computational modeling of the field confinement in such an optically-controlled circuit by in-vitro and in-vivo measurements. Most importantly, using this strategy, we demonstrated that the grating acuity with 40 μm pixels matches the pixel pitch, while with 20 μm pixels, it reaches the 28 μm limit of the natural visual resolution in rats. This method enables customized field shaping based on individual retinal thickness and distance from the implant, paving the way to higher acuity of prosthetic vision in atrophic macular degeneration.

23 July 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TFThomas Flores
Thomas Flores
THTiffany Huang
Tiffany Huang
MBMohajeet Bhuckory
Mohajeet Bhuckory
EHElton Ho
Elton Ho
ZCZhijie Charles Chen
Zhijie Charles Chen
DPDaniel Palanker
Daniel Palanker
High-resolution visual prostheses require small, densely packed pixels, but limited penetration depth of the electric field formed by a planar electrode array constrains such miniaturization. We present a novel honeycomb configuration of an electrode array with vertically separated active and return electrodes designed to leverage migration of retinal cells into voids in the subretinal space. Insulating walls surrounding each pixel decouple the field penetration depth from the pixel width by aligning the electric field vertically, enabling a decrease of the pixel size down to cellular dimensions. We demonstrate that inner retinal cells migrate into the 25 μm deep honeycomb wells as narrow as 18 μm, resulting in more than half of these cells residing within the electrode cavities. Immune response to honeycombs is comparable to that with planar arrays. Modeled stimulation threshold current density with honeycombs does not increase substantially with reduced pixel size, unlike quadratic increase with planar arrays. This 3-D electrode configuration may enable functional restoration of central vision with acuity better than 20/100 for millions of patients suffering from age-related macular degeneration.

30 October 2019 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
EHElton Ho
Elton Ho
XLXin Lei
Xin Lei
TFThomas Flores
Thomas Flores
HLHenri Lorach
Henri Lorach
THTiffany Huang
Tiffany Huang
DPDaniel Palanker
Daniel Palanker
Objective. Retinal prostheses aim to restore sight by electrically stimulating the surviving retinal neurons. In clinical trials of the current retinal implants, prosthetic visual acuity does not exceed 20/550. However, to provide meaningful restoration of central vision in patients blinded by age-related macular degeneration (AMD), prosthetic acuity should be at least 20/200, necessitating a pixel pitch of about 50 µm or lower. With such small pixels, stimulation thresholds are high due to limited penetration of electric field into tissue. Here, we address this challenge with our latest photovoltaic arrays and evaluate their performance in vivo. Approach. We fabricated photovoltaic arrays with 55 and 40 µm pixels (a) in flat geometry, and (b) with active electrodes on 10 µm tall pillars. The arrays were implanted subretinally into rats with degenerate retina. Stimulation thresholds and grating acuity were evaluated using measurements of the visually evoked potentials (VEP). Main results. With 55 µm pixels, we measured grating acuity of 48 ± 11 µm, which matches the linear pixel pitch of the hexagonal array. This geometrically corresponds to a visual acuity of 20/192 in a human eye, matching the threshold of legal blindness in the US (20/200). With pillar electrodes, the irradiance threshold was nearly halved, and duration threshold reduced by more than three-fold, compared to flat pixels. With 40 µm pixels, VEP was too low for reliable measurements of the grating acuity, even with pillar electrodes. Significance. While being helpful for treating a complete loss of sight, current prosthetic technologies are insufficient for addressing the leading cause of untreatable visual impairment—AMD. Subretinal photovoltaic arrays may provide sufficient visual acuity for restoration of central vision in patients blinded by AMD.

16 March 2021 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
THTiffany W Huang
Tiffany W Huang
TKTheodore I Kamins
Theodore I Kamins
ZCZhijie Charles Chen
Zhijie Charles Chen
BWBing-Yi Wang
Bing-Yi Wang
MBMohajeet Bhuckory
Mohajeet Bhuckory
DPDaniel Palanker
Daniel Palanker
Objective. To restore central vision in patients with atrophic age-related macular degeneration, we replace the lost photoreceptors with photovoltaic pixels, which convert light into current and stimulate the secondary retinal neurons. Clinical trials demonstrated prosthetic acuity closely matching the sampling limit of the 100 μ m pixels, and hence smaller pixels are required for improving visual acuity. However, with smaller flat bipolar pixels, the electric field penetration depth and the photodiode responsivity significantly decrease, making the device inefficient. Smaller pixels may be enabled by (a) increasing the diode responsivity using vertical p–n junctions and (b) directing the electric field in tissue vertically. Here, we demonstrate such novel photodiodes and test the retinal stimulation in a vertical electric field. Approach. Arrays of silicon photodiodes of 55, 40, 30, and 20 μ m in width, with vertical p–n junctions, were fabricated. The electric field in the retina was directed vertically using a common return electrode at the edge of the device. Optical and electronic performance of the diodes was characterized in-vitro , and retinal stimulation threshold measured by recording the visually evoked potentials in rats with retinal degeneration. Main results. The photodiodes exhibited sufficiently low dark current (<10 pA) and responsivity at 880 nm wavelength as high as 0.51 A W −1 , with 85% internal quantum efficiency, independent of pixel size. Field mapping in saline demonstrated uniformity of the pixel performance in the array. The full-field stimulation threshold was as low as 0.057 ± 0.029 mW mm −2 with 10 ms pulses, independent of pixel size. Significance. Photodiodes with vertical p–n junctions demonstrated excellent charge collection efficiency independent of pixel size, down to 20 μ m. Vertically oriented electric field provides a stimulation threshold that is independent of pixel size. These results are the first steps in validation of scaling down the photovoltaic pixels for subretinal stimulation.

2 October 2025 in Nature Biomedical Engineering
Verified
Journal Article
Open access
PDF file
MHMark Hettick
Mark Hettick
EHElton Ho
Elton Ho
APAdam J. Poole
Adam J. Poole
MMManuel Monge
Manuel Monge
DPDemetrios Papageorgiou
Demetrios Papageorgiou
BRBenjamin I. Rapoport
Benjamin I. Rapoport
High-bandwidth brain–computer interfaces rely on invasive surgical procedures or brain-penetrating electrodes. Here we describe a cortical 1,024-channel thin-film microelectrode array and we demonstrate its minimally invasive surgical delivery that avoids craniotomy in porcine models and cadavers. We show recording and stimulation from the same electrodes to large portions of the cortical surface, and the reversibility of delivering the implants to multiple functional regions of the brain without damaging the cortical surface. We evaluate the performance of the interface for high-density neural recording and visualizing cortical surface activity at spatial and temporal resolutions and total spatial extents. We demonstrate accurate neural decoding of somatosensory, visual and volitional walking activity, and achieve focal neuromodulation through cortical stimulation at sub-millimetre scales. We report the feasibility of intraoperative use of the device in a five-patient pilot clinical study with anaesthetized and awake neurosurgical patients, characterizing the spatial scales at which sensorimotor activity and speech are represented at the cortical surface. The presented neural interface demonstrates the highly scalable nature of micro-electrocorticography and its utility for next-generation brain–computer interfaces.

16 February 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
EHElton Ho
Elton Ho
HLHenri Lorach
Henri Lorach
GGGeorges Goetz
Georges Goetz
FLFlorian Laszlo
Florian Laszlo
XLXin Lei
Xin Lei
DPDaniel Palanker
Daniel Palanker
Subretinal prostheses are designed to restore sight in patients blinded by retinal degeneration using electrical stimulation of the inner retinal neurons. To relate retinal output to perception, we studied behavioral thresholds in blind rats with photovoltaic subretinal prostheses stimulated by full-field pulsed illumination at 20 Hz, and measured retinal ganglion cell (RGC) responses to similar stimuli ex-vivo. Behaviorally, rats exhibited startling response to changes in brightness, with an average contrast threshold of 12%, which could not be explained by changes in the average RGC spiking rate. However, RGCs exhibited millisecond-scale variations in spike timing, even when the average rate did not change significantly. At 12% temporal contrast, changes in firing patterns of prosthetic response were as significant as with 2.3% contrast steps in visible light stimulation of healthy retinas. This suggests that millisecond-scale changes in spiking patterns define perceptual thresholds of prosthetic vision. Response to the last pulse in the stimulation burst lasted longer than the steady-state response during the burst. This may be interpreted as an excitatory OFF response to prosthetic stimulation, and can explain behavioral response to decrease in illumination. Contrast enhancement of images prior to delivery to subretinal prosthesis can partially compensate for reduced contrast sensitivity of prosthetic vision.