2 September 2016 in Science Advances
Carbon nanotubes (CNTs) are tantalizing candidates for semiconductor electronics because of their exceptional charge transport properties and one-dimensional electrostatics. Ballistic transport approaching the quantum conductance limit of 2G0 = 4e2/h has been achieved in field-effect transistors (FETs) containing one CNT. However, constraints in CNT sorting, processing, alignment, and contacts give rise to nonidealities when CNTs are implemented in densely packed parallel arrays such as those needed for technology, resulting in a conductance per CNT far from 2G0. The consequence has been that, whereas CNTs are ultimately expected to yield FETs that are more conductive than conventional semiconductors, CNTs, instead, have underperformed channel materials, such as Si, by sixfold or more. We report quasi-ballistic CNT array FETs at a density of 47 CNTs μm−1, fabricated through a combination of CNT purification, solution-based assembly, and CNT treatment. The conductance is as high as 0.46 G0 per CNT. In parallel, the conductance of the arrays reaches 1.7 mS μm−1, which is seven times higher than the previous state-of-the-art CNT array FETs made by other methods. The saturated on-state current density is as high as 900 μA μm−1 and is similar to or exceeds that of Si FETs when compared at and equivalent gate oxide thickness and at the same off-state current density. The on-state current density exceeds that of GaAs FETs as well. This breakthrough in CNT array performance is a critical advance toward the exploitation of CNTs in logic, high-speed communications, and other semiconductor electronics technologies.
1 October 1992 in Review of Scientific Instruments
Previous studies of plasma microturbulence have indicated that the fluctuation power scales with radial wave number, k⊥ , like k⊥−2→k⊥−3.5 for k⊥ ≥2 cm−1. This implies that low k fluctuations may dominate the spectrum. Beam emission spectroscopy (BES) has been developed to provide spatially localized measurements of density fluctuations in this low k region of the spectrum (k⊥ ≤2 cm−1). A 20‐channel system has been installed on TFTR which images one of the heating neutral beams (via fiber optics) onto a set of photoconductive photodiode detectors. Fluctuations in the fluorescent Dα emission from the beam can be related to the local plasma density fluctuations via a model of the atomic excitation processes. The analysis of BES data utilizes many of the standard statistical analysis techniques such as power spectra, coherency and cross phase, and correlation analysis which are also used in the analysis of, for example, Langmuir probe data. In the case of BES however, these techniques require some special modifications to account for systematic effects such as photon statistics and fluctuations in the neutral beam density induced by the strong fluctuations near the plasma edge.
1 February 1998 in Nuclear Fusion
28 July 2009 in Nano Letters
1 February 1998 in Review of Scientific Instruments
A fast method and compact device for mixing sub-microliter fluid samples contained in glass capillaries is presented. The fluid is rapidly moved back and forth by air volume displacement driven by a piezo-ceramic actuator. Rapid mixing of different fluids is achieved via diffusion between the main fluid volume in the capillary and the thin fluid film it deposits on the capillary wall through its motion. Bubbles in the fluid are processed out of the capillary by use of an asymmetric velocity profile. A simple analysis model is used to optimize the design of the device and to elucidate the mechanisms involved in mixing. The mixing time is found to be inversely proportional to the fraction of the fluid volume that is left in the film layer for each cycle, which is determined by the wetting properties and the viscosity. The mixing time is therefore controlled by the dead-air volume of the system, the fluid volume, the capillary size, and the displacement limits of the piezo-ceramic actuator, in addition to the intrinsic properties of the fluid being mixed. The device described can mix two 1 μl water solutions in under 3 s. The possible shear breakage of DNA in solution is investigated, and λ-DNA is found to remain intact at aggressive mixing parameters. No evidence of aerosol contamination in polymerase chain reaction reactions was found to date.
1 January 1995 in Review of Scientific Instruments