1 September 2013 in Journal of Crystal Growth
22 July 2011 in IEEE Transactions on Nuclear Science
Poor crystallinity remains a major problem affecting the availability and cost of CdZnTe (CZT) detectors. Point defects are responsible for small gradual charge loss and correlated with the electron clouds' drift times, which allows electronic correction of the output signals to achieve high spectral-resolution even with large-volume CZT detectors. In contrast, extended defects causes significant charge losses, which typically are uncorrelated, and, thus, result in much greater fluctuations of the output signals that cannot be corrected. Although extended defects do not affect all the interaction events, their fraction rapidly increases with the crystal's thickness and volume. In this paper, we summarize our recent results from testing CZT material and detectors that emphasize the particular roles of two types of extended defects, and their contributions to the device's overall performance.
15 March 2012 in IEEE Transactions on Nuclear Science
New results from testing an array of 6 $\,\times\,$ 6 $\,\times\,$ 15 mm $^{3}$ virtual Frisch-grid CdZnTe (CZT) detectors with common-cathode readout for charge signals correction and rejection of incomplete charge collection events (ICC) are presented. The array employs parallelepiped-shaped crystals of a large geometrical aspect ratio with two planar contacts on the top and bottom surfaces (anode and cathode) and an additional shielding electrode placed on the sides to create the virtual Frisch-grid effect. The detectors are arranged in 2 $\,\times\,$ 2 or 3 $\,\times\,$ 3 detector modules with the common cathode readout by a single electronic channel. Because of the common cathode, the length of the shielding electrode can be further reduced with no adverse effects on the device performance. By implementing a novel technique for rejecting ICC events caused by the extended defects, we can achieve good spectral responses from ordinary CZT crystals, which can be produced with higher yield and at lower cost. For such crystals, the resolution of individual detectors is expected to be in the range of 0.8–1.5% FWHM at 662 keV with an average value of 1.3%. Arrays of virtual Frisch-grid detectors offer a robust and low-cost approach for making large-area detection modules that can potentially substitute for more advanced, but also more expensive and less available, pixel detectors in applications with slightly relaxed requirements on position- and energy-resolution (e.g., for coded aperture telescopes). In addition, such virtual Frisch-grid arrays will require a comparably smaller number of readout channels, which allows for lower power consumption.
21 January 2015 in Journal of Phase Equilibria and Diffusion
1 September 2012 in Journal of Crystal Growth
1 September 2010 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment