Tristan Anselm Kuder

Tristan Anselm Kuder

Auto-generated profile, based on publicly available information

Tristan Anselm Kuder

Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Faculty of Physics and Astronomy, Heidelberg University, Im Neuenheimer Feld 226, 69120 Heidelberg, Germany

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2019 in Radiology
Verified
Journal Article
Closed access
PSPatrick Schelb
Patrick Schelb
SKSimon Kohl
Simon Kohl
JRJan Philipp Radtke
Jan Philipp Radtke
MWManuel Wiesenfarth
Manuel Wiesenfarth
PKPhilipp Kickingereder
Philipp Kickingereder
DBDavid Bonekamp
David Bonekamp
A deep learning algorithm (U-Net) trained to evaluate T2-weighted and diffusion MRI had similar detection of clinically significant prostate cancer to clinical Prostate Imaging Reporting and Data S... Background Men suspected of having clinically significant prostate cancer (sPC) increasingly undergo prostate MRI. The potential of deep learning to provide diagnostic support for human interpretat...

29 September 2015 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
NSNoam Shemesh
Noam Shemesh
SJSune N. Jespersen
Sune N. Jespersen
DADaniel C. Alexander
Daniel C. Alexander
YCYoram Cohen
Yoram Cohen
IDIvana Drobnjak
Ivana Drobnjak
CWCarl‐Fredrik Westin
Carl‐Fredrik Westin

1 October 2018 in Radiology
Verified
Journal Article
Closed access
DBDavid Bonekamp
David Bonekamp
SKSimon Kohl
Simon Kohl
MWManuel Wiesenfarth
Manuel Wiesenfarth
PSPatrick Schelb
Patrick Schelb
JRJan Philipp Radtke
Jan Philipp Radtke
LMLena Maier-Hein
Lena Maier-Hein
Quantitative measurement of the mean apparent diffusion coefficient (ADC) was more accurate than prospective clinical assessment in classifying a lesion as clinically significant prostate cancer rather than a benign lesion or clinically insignificant prostate cancer. No added benefit of radiomic machine learning was present compared with mean ADC values alone. PurposeTo compare biparametric contrast-free radiomic machine learning (RML), mean apparent diffusion coefficient (ADC), and radiologist assessment for characterization of prostate lesions detected during prospective MRI interpretation.Materials and MethodsThis single-institution study included 316 men (mean age ± standard deviation, 64.0 years ± 7.8) with an indication for MRI–transrectal US fusion biopsy between May 2015 and September 2016 (training cohort, 183 patients; test cohort, 133 patients). Lesions identified by prospective clinical readings were manually segmented for mean ADC and radiomics analysis. Global and zone-specific random forest RML and mean ADC models for classification of clinically significant prostate cancer (Gleason grade group ≥ 2) were developed on the training set and the fixed models tested on an independent test set. Clinical readings, mean ADC, and radiomics were compared by using the McNemar test and receiver operating characteristic (ROC) analysis.ResultsIn the test set, ...

1 August 2015 in Investigative Radiology
Verified
Journal Article
Closed access
MRMatthias C. Roethke
Matthias C. Roethke
TKTristan A. Kuder
Tristan A. Kuder
TKTimur H. Kuru
Timur H. Kuru
MFMichael Fenchel
Michael Fenchel
BHBoris A. Hadaschik
Boris A. Hadaschik
BSBram Stieltjes
Bram Stieltjes
The purpose of the study was to evaluate and validate diffusion kurtosis imaging (DKI) for detection grading of peripheral zone prostate cancer (PCa) compared with standard diffusion-weighted imaging (DWI) in a cohort of patients with biopsy-proven PCa. In this retrospective, single-institutional study, 55 patients (age, 67.5 ± 6.9 years; range, 52-84 years) who underwent multiparametric magnetic resonance imaging (MRI) before transperineal magnetic resonance/transrectal ultrasound-guided fusion biopsy were included. Suspicious lesions identified in multiparametric MRI underwent image-guided targeted biopsy procedure using a hybrid magnetic resonance/transrectal ultrasound-guided fusion biopsy system. Multiparametric MRI examinations were performed at 3.0 T using a 16-channel phased array coil. Diffusion kurtosis imaging has been acquired with 9 b values (0, 50, 250, 500, 750, 1000, 1250, 1500, and 2000 s/mm). In patients with histologically proven PCa, a representative tumor region was determined as region of interest (ROI) on axial T2-weighted images in consensus by 2 board-certified radiologists. For quantitative evaluation, ROIs located in malignant and contralateral tumor-free regions were transferred to diffusion-weighted images. Diffusion kurtosis imaging parameters (Dapp and Kapp) and apparent diffusion coefficient (ADC) values of the ROIs in tumor and contralateral remote areas were calculated. Estimation of the kurtosis-derived parameters was performed using a voxel-by-voxel fit followed by an ROI-based averaging and a second fit to ROI-averaged signal values. A subgroup analysis was performed to determine the influence of aggressiveness of PCa using ADC, Dapp, and Kapp. The receiver operating characteristic (ROC) curves were calculated for DKI parameters and ADC values. In the 55 patients, the average prostate-specific antigen level was 12.4 ± 12.6 ng/mL (range, 2.7–75.0 ng/mL), and the median Gleason score was 7 (range, 6–10). Dapp (units, 10(-3) mm(2)/s) was significantly lower in tumor compared with control regions (1.48 ± 0.35 vs 2.00 ± 0.32, P < 0.05), and Kapp was significantly higher (1.01 ± 0.21 vs 0.76 ± 0.14, P < 0.05). Dapp was significantly higher than standard ADC (units, 10(-3) mm(2)/s) both in tumor regions and in controls (1.48 ± 0.35 vs 1.10 ± 0.25 and 2.00 ± 0.32 vs 1.43 ± 0.25, P < 0.05). Neither the ROI-based calculation of the kurtosis parameters nor the application of the noise correction significantly changed the DKI parameter estimation. There was no significant difference for the applied fitting method for DKI-derived parameters considering the differentiation between tumor and control tissue. Subsequent ROC analyses did not reveal a significant difference between DKI and ADC for detection of PCa. Sensitivities derived by Youden J statistics cutoff values ranged from 69% to 91% for DKI parameters; specificities ranged from 71% to 89%. Subgroup analysis for DKI (Dapp, Kapp) and ADC for assessing aggressiveness of PCa found significant difference (P < 0.05) for discrimination between high- and low-grade findings. However, no significant difference could be obtained between standard DWI- and DKI-derived parameters. The results of this study demonstrated no significant benefit of DKI for detection and grading of PCa as compared with standard ADC in the peripheral zone determined from b values of 0 and 800 s/mm. For clinical routine application, ADC derived from monoexponential fitting of DWI data remains the standard for characterizing peripheral zone cancer of the prostate.

1 June 2018 in Radiology
Verified
Journal Article
Closed access
SBSebastian Bickelhaupt
Sebastian Bickelhaupt
PJPaul Ferdinand Jaeger
Paul Ferdinand Jaeger
FLFrederik Bernd Laun
Frederik Bernd Laun
WLWolfgang Lederer
Wolfgang Lederer
HDHeidi Daniel
Heidi Daniel
LMLena Maier-Hein
Lena Maier-Hein
Purpose To evaluate a radiomics model of Breast Imaging Reporting and Data System (BI-RADS) 4 and 5 breast lesions extracted from breast-tissue-optimized kurtosis magnetic resonance (MR) imaging for lesion characterization by using a sensitivity threshold similar to that of biopsy. Materials and Methods This institutional study included 222 women at two independent study sites (site 1: training set of 95 patients; mean age ± standard deviation, 58.6 years ± 6.6; 61 malignant and 34 benign lesions; site 2: independent test set of 127 patients; mean age, 58.2 years ± 6.8; 61 malignant and 66 benign lesions). All women presented with a finding suspicious for cancer at x-ray mammography (BI-RADS 4 or 5) and an indication for biopsy. Before biopsy, diffusion-weighted MR imaging (b values, 0-1500 sec/mm2) was performed by using 1.5-T imagers from different MR imaging vendors. Lesions were segmented and voxel-based kurtosis fitting adapted to account for fat signal contamination was performed. A radiomics feature model was developed by using a random forest regressor. The fixed model was tested on an independent test set. Conventional interpretations of MR imaging were also assessed for comparison. Results The radiomics feature model reduced false-positive results from 66 to 20 (specificity 70.0% [46 of 66]) at the predefined sensitivity of greater than 98.0% [60 of 61] in the independent test set, with BI-RADS 4a and 4b lesions benefiting from the analysis (specificity 74.0%, [37 of 50]; 60.0% [nine of 15]) and BI-RADS 5 lesions showing no added benefit. The model significantly improved specificity compared with the median apparent diffusion coefficient (P < .001) and apparent kurtosis coefficient (P = .02) alone. Conventional reading of dynamic contrast material-enhanced MR imaging provided sensitivity of 91.8% (56 of 61) and a specificity of 74.2% (49 of 66). Accounting for fat signal intensity during fitting significantly improved the area under the curve of the model (P = .001). Conclusion A radiomics model based on kurtosis diffusion-weighted imaging performed by using MR imaging machines from different vendors allowed for reliable differentiation between malignant and benign breast lesions in both a training and an independent test data set.

15 November 2006 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
CDChristoph Dehnert
Christoph Dehnert
FRFrank Risse
Frank Risse
SLSebastian Ley
Sebastian Ley
TKTristan A. Kuder
Tristan A. Kuder
RBRalf Buhmann
Ralf Buhmann
CFChristian Fink
Christian Fink
Rationale: Inhomogeneous hypoxic pulmonary vasoconstriction causing regional overperfusion and high capillary pressure is postulated for explaining how high pulmonary artery pressure leads to high-altitude pulmonary edema in susceptible (HAPE-S) individuals. Objective: Because different species of animals also show inhomogeneous hypoxic pulmonary vasoconstriction, we hypothesized that inhomogeneity of lung perfusion in general increases in hypoxia, but is more pronounced in HAPE-S. For best temporal and spatial resolution, regional pulmonary perfusion was assessed by dynamic contrast-enhanced magnetic resonance imaging. Methods: Dynamic contrast-enhanced magnetic resonance imaging and echocardiography were performed during normoxia and after 2 h of hypoxia (FiO2=0.12) in 11 HAPE-S individuals and 10 control subjects. As a measure for perfusion inhomogeneity, the coefficient of variation for two perfusion parameters (peak signal intensity, time-to-peak) was determined for the whole lung and isogravitational slices. Results: There were no differences in perfusion inhomogeneity between the groups in normoxia. In hypoxia, analysis of coefficients of variation indicated a greater inhomogeneity in all subjects, which was more pronounced in HAPE-S compared with control subjects. Discrimination between HAPE-S and control subjects was best in gravity-dependent lung areas. Pulmonary artery pressure during hypoxia increased from 22 ± 3 to 53 ± 9 mm Hg in HAPE-S and 24 ± 4 to 33 ± 6 mm Hg in control subjects (mean ± SD; p < 0.001), respectively. Conclusion: This study shows that hypoxic pulmonary vasoconstriction is inhomogeneous in hypoxia in humans, particularly in HAPE-S individuals where it is accompanied by a greater increase in pulmonary artery pressure compared with control subjects. These findings support the hypothesis of exaggerated and uneven hypoxic pulmonary vasoconstriction in HAPE-S individuals.