7 December 2018 in Science Advances
Intraoperative imaging of tumor microenvironment reveals correlations between extracellular vesicle density and breast pathology.
29 April 2021 in Biomedical Optics Express
We report an automated differentiation model for classifying malignant tumor, fibro-adipose, and stroma in human breast tissues based on polarization-sensitive optical coherence tomography (PS-OCT). A total of 720 PS-OCT images from 72 sites of 41 patients with H&E histology-confirmed diagnoses as the gold standard were employed in this study. The differentiation model is trained by the features extracted from both one standard OCT-based metric (i.e., intensity) and four PS-OCT-based metrics (i.e., phase difference between two channels (PD), phase retardation (PR), local phase retardation (LPR), and degree of polarization uniformity (DOPU)). Further optimized by forward searching and validated by leave-one-site-out-cross-validation (LOSOCV) method, the best feature subset was acquired with the highest overall accuracy of 93.5% for the model. Furthermore, to show the superiority of our differentiation model based on PS-OCT images over standard OCT images, the best model trained by intensity-only features (usually obtained by standard OCT systems) was also obtained with an overall accuracy of 82.9%, demonstrating the significance of the polarization information in breast tissue differentiation. The high performance of our differentiation model suggests the potential of using PS-OCT for intraoperative human breast tissue differentiation during the surgical resection of breast cancer.
28 November 2018 in Biomedical Optics Express
We report the development and implementation of an intraoperative polarization-sensitive optical coherence tomography (PS-OCT) system for enhancing breast cancer detection. A total of 3440 PS-OCT images were intraoperatively acquired from 9 human breast specimens diagnosed by H&E histology as healthy fibro-adipose tissue (n = 2), healthy stroma (n = 2), or invasive ductal carcinoma (IDC, n = 5). A standard OCT-based metric (coefficient of variation (CV)) and PS-OCT-based metrics sensitive to biological tissue from birefringence (i.e., retardation and degree of polarization uniformity (DOPU)) were derived from 398 statistically different and independent images selected by correlation coefficient analysis. We found the standard OCT-based metric and PS-OCT-based metrics were complementary for the differentiation of healthy fibro-adipose tissue, healthy stroma, and IDC. While the CV of fibro-adipose tissue was significantly higher (p<0.001) than those of either stroma or IDC, the CV difference between stroma and IDC was minimal. On the other hand, stroma was associated with significantly higher (p<0.001) retardation and significantly lower (p<0.001) DOPU as compared to IDC. By leveraging the complementary information acquired by the intraoperative PS-OCT system, healthy fibro-adipose tissue, healthy stroma, and IDC can be differentiated with an accuracy of 89.4%, demonstrating the potential of PS-OCT as an adjunct modality for enhanced intraoperative differentiation of human breast cancer.
11 May 2024 in Measurement
23 March 2021 in Optics Letters
Defocus aberration in optical systems, including optical coherence tomography (OCT) systems employing Gaussian illumination, gives rise to the well-known compromise between transverse resolution and depth-of-field. This results in blurry images when out-of-focus, whilst other low-order aberrations (e.g., astigmatism, coma, etc.) present in both the OCT system and biological samples further reduce image resolution and contrast. Computational adaptive optics (CAO) is a computed optical interferometric imaging technique that modifies the phase of the OCT data in the spatial frequency domain to correct optical aberrations and provide improvement of the image quality throughout the three-dimensional (3D) volume. In this Letter, we report the first implementation of CAO for polarization-sensitive OCT to correct defocus and other low-order aberrations, providing enhanced polarization-sensitive imaging contrast (i.e., intensity and phase retardation) on a 3D OCT phantom, molded plastics, ex vivo chicken breast tissue, and ex vivo human breast cancer tissue.
29 August 2023 in Biomedical Optics Express
Whilst radiotherapy (RT) is widely used for cancer treatment, radiodermatitis caused by RT is one most common severe side effect affecting 95% cancer patients. Accurate radiodermatitis assessment and classification is essential to adopt timely treatment, management and monitoring, which all depend on reliable and objective tools for radiodermatitis grading. We therefore, in this work, reported the development and grading performance validation of a low-cost (∼2318.2 CNY) algorithms-based hyperspectral imaging (aHSI) system for radiodermatitis assessment. The low-cost aHSI system was enabled through Monte Carlo (MC) simulations conducted on multi-spectra acquired from a custom built low-cost multispectral imaging (MSI) system, deriving algorithms-based hyper-spectra with spectral resolution of 1 nm. The MSI system was based on sequentially illuminated narrow-band light-emitting diodes (LEDs) and a CMOS camera. Erythema induced artificially on healthy volunteers was measured by the aHSI system developed, with algorithms-based hyper-spectra and skin layer resolved physiological parameters (i.e., the blood volume fraction (BVF) and the oxygen saturation of hemoglobin in blood, et. al.) derivation using MC simulations. The MC simulations derived BVF and the oxygen saturation of hemoglobin in blood showed significant (P < 0.001, analysis of variance: ANOVA) increase with erythema. Further 1D-convolution neural network (CNN) implemented on the algorithms-based hyper-spectra leads to an overall classification accuracy of 93.1%, suggesting the great potential of low-cost aHSI system developed for radiodermatitis assessment.