1 March 2017 in International Journal of Hydrogen Energy
During the filling of hydrogen tanks high temperatures can be generated inside the vessel because of the gas compression while during the emptying low temperatures can be reached because of the gas expansion. The design temperature range goes from 40 C to 85 C. Temperatures outside that range could affect the mechanical properties of the tank materials. CFD analyses of the filling and emptying processes have been performed in the HyTransfer project. To assess the accuracy of the CFD model the simulation results have been compared with new experimental data for different filling and emptying strategies. The comparison between experiments and simulations is shown for the temperatures of the gas inside the tank, for the temperatures at the interface between the liner and the composite material, and for the temperatures on the external surface of the vessel.JRC.C.1-Energy Storag
1 June 2016 in International Journal of Hydrogen Energy
The influence of the initial tank temperature on the evolution of the internal gas temperature during the refueling of on-board hydrogen tanks is investigated in this paper. Two different types of tanks, four different fuel delivery temperatures (from ambient temperature refueling to a pre-cooled hydrogen at -40°C), several filling rates and initial pressures are considered. It is found that the final gas temperature increases linearly with the increase of the initial tank temperature while the temperature increase and the final state of charge (SOC) decrease linearly with increasing initial temperature. The final temperature dependency on the initial temperature is larger with type III than with type IV tank, and grows with increasing initial pressure. Additionally CFD simulations are performed to better understand the role of the relevant phenomena on the gas temperature histories e.g. gas compression, gas mixing, and heat transfer. By comparing the results of calculations with adiabatic and diathermal tank walls, the effect of the initial gas temperature has been separated from the effect of the initial wall temperature on the process.JRC.F.2-Energy Conversion and Storage Technologie
1 July 2019 in International Journal of Hydrogen Energy
1 December 2014 in International Journal of Hydrogen Energy
At the JRC-IET, commercial hydrogen tanks have been subjected to filling-emptying cycles to investigate their long-term mechanical and thermal behaviour and their safety performance. The local temperature history inside the tanks has been measured and compared with the temperatures outside and at the tank metallic bosses, which is the measurement location identified by some standards. The outcome of these activities is a set of experimental data which will be made publicly available as reference for safety studies validation of computational fluid dynamics.JRC.F.2-Energy Conversion and Storage Technologie
1 November 2016 in International Journal of Hydrogen Energy
In this article we show a refueling strategy analysis using different injector configurations to refuel a 70 MPa composite reinforced type 4 tank. The gas has been injected through single openings of different diameters (3 mm, 6 mm and 10 mm) and alternatively through multiple small holes (4 × 3 mm). For each injector configuration, slow (12 min) and faster (3 min) fillings have been performed. The gas temperature has been measured at different positions inside the tank, as well as the temperatures of the wall materials at various locations: on the external surface and at the interface between the liner and the fiber reinforced composite. In general, the larger the injector diameter and the slower the filling, the higher the chance that the gas develops vertical temperature gradients (a so-called gas temperature stratification), resulting in higher than average temperatures near the top of the tank and lower than average at its bottom. While the single 3 mm opening injector causes homogeneous gas temperatures for both filling speeds, both the 6 mm and 10 mm opening injectors induce gas temperature stratification during the 12 min fillings. The injector with multiple holes has an area comparable to the 6 mm single opening injector: in general, this more complex geometry tends to limit the inhomogeneity of gas temperatures during slow fillings. When gas temperature stratification develops, the wall materials temperature is also locally affected. This results in a higher than average temperature at the top of the tank and higher the slower the filling.