27 January 2023 in Medical Image Analysis
26 July 2021 in IEEE Access
Magnetic resonance imaging (MRI) is an important medical imaging modality, but its acquisition speed is quite slow due to the physiological limitations. Recently, super-resolution methods have shown excellent performance in accelerating MRI. In some circumstances, it is difficult to obtain high-resolution images even with prolonged scan time. Therefore, we proposed a novel super-resolution method that uses a generative adversarial network with cyclic loss and attention mechanism to generate high-resolution MR images from low-resolution MR images by upsampling factors of 2× and 4×. We implemented our model on pelvic images from healthy subjects as training and validation data, while those data from patients were used for testing. The MR dataset was obtained using different imaging sequences, including T2, T2W SPAIR, and mDIXON-W. Four methods, i.e., BICUBIC, SRCNN, SRGAN, and EDSR were used for comparison. Structural similarity, peak signal to noise ratio, root mean square error, and variance inflation factor were used as calculation indicators to evaluate the performances of the proposed method. Various experimental results showed that our method can better restore the details of the high-resolution MR image as compared to the other methods. In addition, the reconstructed high-resolution MR image can provide better lesion textures in the tumor patients, which is promising to be used in clinical diagnosis.
7 March 2023 in IEEE Transactions on Neural Networks and Learning Systems
Magnetic resonance imaging (MRI) possesses the unique versatility to acquire images under a diverse array of distinct tissue contrasts, which makes multicontrast super-resolution (SR) techniques possible and needful. Compared with single-contrast MRI SR, multicontrast SR is expected to produce higher quality images by exploiting a variety of complementary information embedded in different imaging contrasts. However, existing approaches still have two shortcomings: 1) most of them are convolution-based methods and, hence, weak in capturing long-range dependencies, which are essential for MR images with complicated anatomical patterns and 2) they ignore to make full use of the multicontrast features at different scales and lack effective modules to match and aggregate these features for faithful SR. To address these issues, we develop a novel multicontrast MRI SR network via transformer-empowered multiscale feature matching and aggregation, dubbed McMRSR $^{++}$ . First, we tame transformers to model long-range dependencies in both reference and target images at different scales. Then, a novel multiscale feature matching and aggregation method is proposed to transfer corresponding contexts from reference features at different scales to the target features and interactively aggregate them Furthermore, a texture-preserving branch and a contrastive constraint are incorporated into our framework for enhancing the textural details in the SR images. Experimental results on both public and clinical in vivo datasets show that McMRSR $^{++}$ outperforms state-of-the-art methods under peak signal to noise ratio (PSNR), structure similarity index measure (SSIM), and root mean square error (RMSE) metrics significantly. Visual results demonstrate the superiority of our method in restoring structures, demonstrating its great potential to improve scan efficiency in clinical practice.
7 June 2021 in IEEE Access
Compressed sensing (CS) can speed up the magnetic resonance imaging (MRI) process and reconstruct high-quality images from under-sampled k-space data. However, traditional CS-MRI suffers from slow iterations and artifacts caused by noise when the acceleration factor is high. Currently, deep learning has been introduced to address these issues. Although some improvements have been achieved, the reconstruction problem under high under-sampling rates has not been solved. Thus, our study proposed a novel CS-MRI reconstruction method called RSCA-GAN. The generator of RSCA-GAN is a residual U-net consisting of both spatial and channel-wise attention. The proposed RSCA-GAN was compared to the zero-filling, DAGAN, RefineGAN, and RCA-GAN using both cartesian and non-cartesian under-sampling masks on brain and knee datasets. The sampling rates of cartesian masks are 25%, 16.7%, and 12.5% and the sampling rates of spiral and radial masks are 30%, 20%, and 10%. Peak signal-to-noise ratio (PSNR), structural similarity (SSIM) and normalized mean square error (NMSE) were used to evaluate the reconstructed image quality, and the rank-sum test was adopted to evaluate the significant difference among different approaches. P <; 0.05 indicated statistical significance. The results demonstrated that RSCA-GAN outperforms the other approaches for all the quantitative metrics. Thus, RSCA-GAN exhibits excellent reconstruction performance at high under-sampling rates and is suitable for clinical applications.