Durga Prasad Ghosh

Durga Prasad Ghosh

Auto-generated profile, based on publicly available information

Durga Prasad Ghosh

Oregon State University, Corvallis, OR 97331, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2022 in Water Research
Verified
Journal Article
Closed access
DSDeepak Sharma
Deepak Sharma
DGDurga Prasad Ghosh
Durga Prasad Ghosh
SDSandra Jean Dennis
Sandra Jean Dennis
BABahman Abbasi
Bahman Abbasi

3 September 2021 in IEEE Transactions on Components, Packaging and Manufacturing Technology
Verified
Journal Article
Closed access
DGDurga Prasad Ghosh
Durga Prasad Ghosh
DSDeepak Sharma
Deepak Sharma
BABahman Abbasi
Bahman Abbasi
Efficient thermal management is crucial for enhancing the performance and reliability of electronic devices. In this regard, flow boiling with microchannels promises high heat dissipation capability for a nominal temperature budget as it inherently takes advantage of high latent heat of vaporization along with high surface area to volume ratio. However, the promise of high heat dissipation in flow boiling microchannels is limited by two-phase flow instabilities which cause large-amplitude temperature and pressure fluctuations. The current state-of-the-art thermal management techniques for enhancing heat transfer during flow boiling in microchannels operate in steady state condition and provide sufficient continuous cooling to address the peak thermal loads. While such approaches can manage the thermal challenge, they result in significant cooling overdesign. To eliminate the overdesign, we introduce an adaptive vapor venting strategy which continuously adjusts to the varying vapor generation across different heat fluxes to completely mitigate two-phase fluctuations. Our results demonstrate that significant transient temperature fluctuations (±5°C) in the conventional microchannels were completely eliminated with the incorporation of the adaptive vapor venting (within the experimental uncertainty). Further, our results show that this strategy has the capability to handle transience and accordingly avoid the need for cooling overdesign.

16 July 2021
Verified
Preprint
Open access
DSDeepak Sharma
Deepak Sharma
SDSandra Jean Dennis
Sandra Jean Dennis
JRJordan Neal Rote
Jordan Neal Rote
DGDurga Prasad Ghosh
Durga Prasad Ghosh
XZXiang Zhang
Xiang Zhang
BABahman Abbasi
Bahman Abbasi
In order to meet the increased water demand triggered by population explosion, rapid industrialization, agriculture development, and tourism, many water-stressed regions are augmenting their water supply with desalinated water. Further, in some areas such as Qatar and Kuwait, 100% of domestic and industrial water demand is supplied through desalination implying development of