Rashid Yasin

Rashid Yasin

Auto-generated profile, based on publicly available information

Rashid Yasin

Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2020 in The International Journal of Robotics Research
Verified
Journal Article
Open access
PDF file
RYRashid Yasin
Rashid Yasin
NSNabil Simaan
Nabil Simaan
Continuum robots offer the dexterity and obstacle circumvention capabilities necessary to enable surgery in deep surgical sites. They also can enable joint-level ex situ force sensing (JEFS), which provides an estimate of end-effector wrenches given joint-level forces. Prior works on JEFS relied on a restrictive embodiment with minimal actuation line friction and captured model and frictional actuation transmission uncertainties using a configuration space formulation. In this work, we overcome these limitations. First, frictional losses are canceled using a feed-forward term based on support vector regression in joint space. Then, regression maps and their interpolation are used to account for actuation hysteresis. The residual joint-force error is then further minimized using a least-squares model parameter update. An indirect hybrid force/position controller using JEFS is presented with evaluation carried out on a realistic pre-clinically deployable insertable robotic effectors platform (IREP) for single-port access surgery. Automated mock force-controlled ablation, exploration, and knot tightening are evaluated. A user study involving the daVinci Research Kit surgeon console and the IREP as a surgical slave was carried out to compare the performance of users with and without force feedback based on JEFS for force-controlled ablation and knot tightening. Results in automated experiments and a user study of telemanipulated experiments suggest that intrinsic force-sensing can achieve levels of force uncertainty and force regulation errors of the order of 0.2 N. Using JEFS and automated task execution, repeatability, and force regulation accuracy is shown to be comparable to using a commercial force sensor for human-in-the-loop feedback.

2 February 2018 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
PCPreetham Chalasani
Preetham Chalasani
LWLong Wang
Long Wang
RYRashid Yasin
Rashid Yasin
NSNabil Simaan
Nabil Simaan
RTRussell H. Taylor
Russell H. Taylor
During open surgeries, surgeons use tactile palpation to form an understanding of the anatomy, including any underlying anatomical structures such as arteries or tumors. This letter explores methods for restoring this capability in the context of minimally invasive robot-assisted surgery. Previous works have demonstrated the ability of robots to use discrete palpation to characterize organ shape and, when followed with offline data processing, to produce a stiffness map of the organ. In our earlier work, we presented an offline estimation technique, independent of palpation strategy, to estimate organ shape and stiffness using Gaussian processes. This study extends our prior work by demonstrating a fast online technique for estimation of organ shape and stiffness. Our goal is to provide near video-frame-rate updates of the organ geometry and tissue stiffness during force controlled exploration. Two different palpation modes are experimentally explored: autonomous palpation and constrained semiautonomous teleoperation. We report the experimental evaluation of our approach for stiffness estimation using autonomous palpation. And we demonstrate the feasibility of using our method during interactive teleoperation in a simulated surgical scenario. We believe that future use of the online stiffness and geometry information based on our proposed method can help surgeons in improving their understanding of the surgical scene and its correlation to preoperative imaging, thereby increasing safety and improving surgical outcomes.

9 March 2017 in Journal of Mechanisms and Robotics
Verified
Journal Article
Closed access
PDF file
LWLong Wang
Long Wang
ZCZihan Chen
Zihan Chen
PCPreetham Chalasani
Preetham Chalasani
RYRashid M. Yasin
Rashid M. Yasin
PKPeter Kazanzides
Peter Kazanzides
NSNabil Simaan
Nabil Simaan
This paper proposes an approach for using force-controlled exploration data to update and register an a priori virtual fixture geometry to a corresponding deformed and displaced physical environment. An approach for safe exploration implementing hybrid motion/force control is presented on the slave robot side. During exploration, the shape and the local surface normals of the environment are estimated and saved in an exploration data set. The geometric data collected during this exploration scan are used to deform and register the a priori environment model to the exploration data set. The environment registration is achieved using a deformable registration based on the coherent point drift method. The task-description of the high-level assistive telemanipulation law, called a virtual fixture (VF), is then deformed and registered in the new environment. The new model is updated and used within a model-mediated telemanipulation framework. The approach is experimentally validated using a da-Vinci research kit (dVRK) master interface, a dVRK patient side manipulator, and a Cartesian stage robot. Experiments demonstrate that the updated VF and the updated model allow the users to improve their path following performance and to shorten their completion time when the updated path following VF is applied. The approach presented has direct bearing on a multitude of surgical applications including force-controlled ablation.

1 February 2017 in Otology & Neurotology
Verified
Journal Article
Closed access
RYRashid Yasin
Rashid Yasin
BOBrendan P. O’connell
Brendan P. O’connell
HYHaoran Yu
Haoran Yu
JHJacob B. Hunter
Jacob B. Hunter
GWGeorge B. Wanna
George B. Wanna
NSNabil Simaan
Nabil Simaan
Hypothesis: The use of a robotic manipulator with a dexterously orientable gripper will expand the ability of middle ear surgeons to perform precise tasks and access otherwise challenging anatomic regions. Background: Middle ear surgery presents unique challenges because of the constrained operative space and limited access to certain anatomic regions. Methods: A custom-designed robot with a sideways-reaching gripper was used to evaluate feasibility of manipulation tasks in different middle-ear anatomical zones. Reachable workspace within the middle ear, accuracy of free-space path following, and tool steadiness were compared between robotic telemanipulation and manual control. Preliminarily assessments of the robot's clinical utility included: 1) touching the round window niche, Eustachian tube orifice, and sinus tympani; 2) placing a stapes prosthesis; 3) removal of mockup diseased tissue in the sinus tympani. Results: The reachable workspace in the middle ear was considerably greater with the robot as compared with manual manipulation using a Rosen needle. In a simple path-tracing task outside the ear, robotic telemanipulation was associated with significantly reduced error. Within the middle ear, the robot contributed to steadier movement, but longer task completion time. The gripper successfully placed a 4.5 mm piston prosthesis, accessed the round window niche, Eustachian tube orifice, and removed mockup disease from the sinus tympani. Conclusion: This study demonstrates that robotic assistance using steerable tools allows surgeons to access challenging anatomic regions of the middle ear. Coordinated and accurate manipulation is evidenced by motion analyses and completion of feasibility tasks within the middle ear.

8 December 2020 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
RYRashid Yasin
Rashid Yasin
PCPreetham Chalasani
Preetham Chalasani
NZNicolas Zevallos
Nicolas Zevallos
MSMahya Shahbazi
Mahya Shahbazi
ZLZhaoshuo Li
Zhaoshuo Li
NSNabil Simaan
Nabil Simaan
The use of intelligent feedback modalities to control and react to interaction forces during surgical procedures is an important factor in enabling safe and precise surgery. We explore the use of a model-mediated telemanipulation framework to enhance a user’s situational awareness using assistive virtual fixtures and semi-automated task execution for safe and intuitive environment interaction during robotic laparoscopic surgery. The framework allows stiffness mapping with semi-autonomous excitation, hybrid position-force control, and model updates during soft geometry contact. A 24-person study was carried out at 3 sites in simulated ablation and palpation of phantom anatomy. Compared to methods lacking intelligent feedback and guidance, the proposed framework improved task execution metrics (force regulation, completion time, path-following error) and reduced user effort.

16 May 2019 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
RYRashid Yasin
Rashid Yasin
MDMatthew Dedmon
Matthew Dedmon
NDNeal Dillon
Neal Dillon
NSNabil Simaan
Nabil Simaan