29 January 2020 in Analytical and Bioanalytical Chemistry
14 June 2024 in Rapid Communications in Mass Spectrometry
Rationale: The isotope ratio for the internationally agreed but virtual zero‐point of the carbon isotope‐delta scale, Vienna Peedee belemnite (VPDB), plays a critical role in linking carbon isotope delta values to the SI. It is also a quantity used for various data processing procedures including ‘ 17 O correction’, clumped isotope analysis and conversion of carbon isotope delta values into other expressions of isotopic composition. A value for R VPDB ( 13 C/ 12 C) with small uncertainty is therefore desirable to facilitate these procedures. Methods: The value of R VPDB ( 13 C/ 12 C) was determined by errors‐in‐variables regression of isotope delta values traceable to VPDB measured by isotope ratio mass spectrometry against isotope ratios traceable to the SI by use of gravimetric mixtures of 12 C‐ and 13 C‐enriched d ‐glucose measured by multicollector inductively coupled plasma mass spectrometry. Results: A value of R VPDB ( 13 C/ 12 C) = 0.0111105 ± 0.0000042 (expanded uncertainty, k = 2) was obtained. Conclusions: The new value for R VPDB ( 13 C/ 12 C) agrees very well with the consensus values calculated from previous measurement results proposed by Kaiser and by ourselves, as well as recent determinations independent of mass spectrometry. The expanded uncertainty of 0.4‰ when expressed as an isotope delta value is a tenfold improvement over the previous best measurement of the isotopic composition of carbon.
15 September 2022 in Geostandards and Geoanalytical Research
: Isotope ratio applications are on the increase and a major part of which are delta measurements, because they are easier to perform than the determination of absolute isotope ratios while offering lower measurement uncertainties. Delta measurements use artefact‐based scales and therefore scale conversions are required due to the lack of the scale defining standards. Such scale conversions often form the basis for comparing data being generated in numerous projects and therefore need to be as accurate as possible. In practice, users are tempted to apply linear approximations, which are not sufficiently exact, because delta values are defined by nonlinear relationships. The bias of such approximations often is beyond typical measurement uncertainties and its extent can hardly be predicted. Therefore, exact calculations are advised. Here, the exact equations and the bias of the approximations are presented, and calculations are illustrated by real‐world examples. Measurement uncertainty is indispensable in this context and therefore, its calculation is described as well for determining delta values but also for scale conversions. Approaches for obtaining a single delta measurement and for repeated measurements are presented. For the latter case, a new approach for calculating the measurement uncertainty is presented, which considers covariances between the isotope ratios.
1 July 2019 in Spectrochimica Acta Part B: Atomic Spectroscopy
23 August 2024 in Analytical and Bioanalytical Chemistry
The gravimetric isotope mixture method is the primary method to determine absolute isotope ratios. This method, however, depends on the existence of suitable spike materials and knowledge of their purities. Determining the purity of the spikes can be tedious and labour-intensive. In this publication, an advancement of the gravimetric isotope mixture method, rendering the determination of the purity of the spike materials unnecessary, is presented. The advancement combines mass spectrometry and ion chromatography leading to an approach being independent of the purity of the spike materials. In the manuscript the mathematical background and the basic idea of the novel approach are described using a two-isotope system like copper or lithium. Graphical
1 June 2020 in Spectrochimica Acta Part B: Atomic Spectroscopy