Quan Li

Quan Li

Auto-generated profile, based on publicly available information

Quan Li

Department of Spine Surgery, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in Journal of Comparative Effectiveness Research
Verified
Journal Article
Open access
XCXiuyuan Chen
Xiuyuan Chen
QSQingxin Song
Qingxin Song
KWKun Wang
Kun Wang
ZCZhi Chen
Zhi Chen
YHYingchao Han
Yingchao Han
QLQuan Li
Quan Li
Aim: To compare the screw accuracy and clinical outcomes between robot-assisted minimally invasive transforaminal lumbar interbody fusion (RA MIS-TLIF) and open TLIF in the treatment of one-level lumbar degenerative disease. Materials & methods: From May 2018 to December 2019, a consecutive series of patients undergoing robot-assisted minimally invasive one-level lumbar fusion procedures were retrospectively compared with matched controls who underwent one-level open TLIF procedures for clinical and quality-of-life outcomes. Results: A total of 52 patients underwent RA MIS-TLIF procedures (robot-assisted [RA] group) and 52 matched controls received freehand open TLIF procedures (open [OP] group). The RA group had more grade A screws with 96.2% one-time success rate of screw placement (p < 0.05). Besides, the RA group experienced less intraoperative blood loss and shorter length of hospital stay, while the OP group had shorter operative duration and cumulative radiation time (p < 0.001). What is more, the average VAS score for low back pain and ODI score in the RA group were lower than that in the OP group 1 month after operation (p < 0.05). Conclusion: The use of real-time, image-guided robot system may further expand the advantages of MIS-TLIF technique in terms of accuracy and safety.

16 September 2020 in Spine
Verified
Journal Article
Closed access
XSXin-Jin Su
Xin-Jin Su
CHCang-Long Hou
Cang-Long Hou
BSBei-Duo Shen
Bei-Duo Shen
WZWei-Zhong Zhang
Wei-Zhong Zhang
DWDe-Sheng Wu
De-Sheng Wu
HSHongxing Shen
Hongxing Shen
Study Design.: A cross-sectional study. Objective.: To assess the effectiveness of a new assessment tool, myelopathy-hand functional evaluation system (MFES), in evaluating the hand dysfunction of patients with cervical myelopathy in the 10-second grip-and-release test (10 second G-R test). Summary of Background Data.: Clumsy fingers movement is a common symptom of myelopathy patients. Evaluating the impaired hand function can provide a strong basis in assessing the severity of myelopathy. Currently, no objective and effective evaluation method is widely accepted in clinical practice. Methods.: MFES mainly consists of a pair of wise-gloves and a computer with software. One hundred and ninety-eight consecutive participants were asked to wear the wise-gloves and then perform 10 seconds G-R test. The movements of each finger were recorded by MFES and converted into waveforms. Relevant waveform parameters were measured and analyzed. The Japanese Orthopedics Association (JOA) scores of each patient were marked and the maximum spinal cord compression (MSCC) was measured on midsagittal T2-weighted magnetic resonance imaging (MRI). Results.: Myelopathy patients had a lower number of G-R cycles and a longer time per cycle than healthy subjects. There were significant differences in adduction and abduction time in patients with JOA scores greater than 6, but not in healthy subjects and patients with JOA scores less than 6. The waveforms of ulnar three fingers in myelopathy patients were lower and wider than those in healthy individuals. The average ratio value of wave height to wave width (a/b) could quantitatively reflect such differences of waveforms. According to receiver operating characteristic (ROC) curve analysis, the optimal threshold value of the normal average ratio was more than 1.92. The average a/b value was correlated with the JOA scores of the motor function in the upper extremities (r = 0.842). Conclusion.: MFES appears to be an objective and quantitative assessment tool for patients with cervical myelopathy. Level of Evidence: 3

1 March 2021 in Clinical Neurology and Neurosurgery
Verified
Journal Article
Closed access
XSXin-Jin Su
Xin-Jin Su
ZLZhen-Dong Lv
Zhen-Dong Lv
WZWei-Zhong Zhang
Wei-Zhong Zhang
QLQuan Li
Quan Li
HSHongxing Shen
Hongxing Shen

1 October 2019 in Journal of Thoracic Oncology
Verified
Journal Article
Closed access
LHL. Huang
L. Huang
YLY. Lv
Y. Lv
WCW. Cang
W. Cang
QLQ. Li
Q. Li
XLX. Liao
X. Liao
LQL. Qiu
L. Qiu