D. Castillo-Morales

D. Castillo-Morales

Auto-generated profile, based on publicly available information

D. Castillo-Morales

EcoNuclear S.A.S. 4 , Bucaramanga

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2025 in Journal of Applied Physics
Verified
Journal Article
Open access
RMR. A. Martínez-Rivero
R. A. Martínez-Rivero
CSC. Sarmiento-Cano
C. Sarmiento-Cano
DCD. Castillo-Morales
D. Castillo-Morales
JPJ. Perea-Pérez
J. Perea-Pérez
VMVíctor Gabriel Baldovino Medrano
Víctor Gabriel Baldovino Medrano
LNLuis A Núñez
Luis A Núñez
This study presents the design and simulation-based validation of a muon imaging system tailored for potential applications in industrial hydrotreatment units. The system is built around a two-panel plastic scintillator hodoscope, equipped with silicon photomultipliers and readout via a CAEN FERS-A5202 acquisition system. The detector was calibrated using a stepwise “staircase” method and characterized under open-sky and controlled conditions. We conducted muon flux attenuation measurements to validate its response using variable lead shielding. We agreed with simulations generated using the MEIGA framework and realistic cosmic-ray spectra from the ARTI simulation chain. With the detector response validated, we modeled muon transmission through a realistic 3D representation of a benchmark unit for producing clean fuels, incorporating internal variations in the density of the fixed bed. By reconstructing angular muon fluxes and computing relative attenuation maps, we demonstrated the system’s capability to detect internal density contrasts. Simulation results indicate that 20 h of exposure to vertical muon flux is sufficient to retrieve structural information. In comparison, inclined configurations (30° and 60° from vertical) require extended exposure times—up to 8 days—yet remain feasible within industrial monitoring schedules. These findings highlight the feasibility of muography as a non-invasive diagnostic tool for complex industrial infrastructure. The proposed system shows strong potential for real-time monitoring of catalyst bed integrity and long-term structural analysis in high-pressure chemical reactors.

18 October 2023 in ACI Avances en Ciencias e Ingenierías
Verified
Journal Article
Open access
PDF file
DCDennis Cazar
Dennis Cazar
MAMario Audelo
Mario Audelo
DCDiego Castillo
Diego Castillo
MHMaría Fernanda Heredia
María Fernanda Heredia
EPEdwin Pozo
Edwin Pozo
La Colaboración LAGO (Latin American Giant Observatory) tiene como objetivo la detección de fotones de alta energía provenientes de GRBs (Gamma Ray Bursts) utilizando detectores Cherenkov de agua (WCD). Para alcanzar la sensibilidad necesaria para la recolección de datos los WCDs deben ser instalados en sitios de altura mayor a 4000 msnm. En este trabajo se describe el diseño de un detector WCD autónomo para su instalación en las faldas del volcán Chimborazo (4310 msnm) desde la mecánica del tanque, su sistema de adquisición y transferencia de datos, generación de energía eléctrica y sistemas de backup para poder garantizar el funcionamiento continuo en el tiempo. Se estima que el WCD podrá funcionar por un período máximo de 18 meses sin mantenimiento, el tratamiento de purificación del agua aumenta considerablemente la transparencia incrementando el numero de fotoelectrones en un factor 2 comparado con otras implementaciones.