Hyunho Park

Hyunho Park

Auto-generated profile, based on publicly available information

Hyunho Park

VUNO Inc., Seoul, Korea

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2020 in ASAIO Journal
Verified
Journal Article
Closed access
JCJinwoo Cho
Jinwoo Cho
BLByeongTak Lee
ByeongTak Lee
JKJoon-myoung Kwon
Joon-myoung Kwon
YLYeha Lee
Yeha Lee
HPHyunho Park
Hyunho Park
KKKyung-hee Kim
Kyung-hee Kim
Although heart failure with reduced ejection fraction (HFrEF) is a common clinical syndrome and can be modified by the administration of appropriate medical therapy, there is no adequate tool available to perform reliable, economical, early-stage screening. To meet this need, we developed an interpretable artificial intelligence (AI) algorithm for HFrEF screening using electrocardiography (ECG) and validated its performance. This retrospective cohort study included two hospitals. An AI algorithm based on a convolutional neural network was developed using 39,371 ECG results from 17,127 patients. The internal validation included 3,470 ECGs from 2,908 patients. Furthermore, we conducted external validation using 4,362 ECGs from 4,176 patients from another hospital to verify the applicability of the algorithm across different centers. The end-point was to detect HFrEF, defined as an ejection fraction <40%. We also visualized the regions in 12 lead ECG that affected HFrEF detection in the AI algorithm and compared this to the previously documented literature. During the internal and external validation, the areas under the curves of the AI algorithm using a 12 lead ECG for detecting HFrEF were 0.913 (95% confidence interval, 0.902–0.925) and 0.961 (0.951–0.971), respectively, and the areas under the curves of the AI algorithm using a single-lead ECG were 0.874 (0.859–0.890) and 0.929 (0.911–0.946), respectively. The deep learning-based AI algorithm performed HFrEF detection well using not only a 12 lead but also a single-lead ECG. These results suggest that HFrEF can be screened not only using a 12 lead ECG, as is typical of a conventional ECG machine, but also with a single-lead ECG performed by a wearable device employing the AI algorithm, thereby preventing irreversible disease progression and mortality.

1 January 2019 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
SPSohee Park
Sohee Park
SLSang Min Lee
Sang Min Lee
KDKyung-Hyun Do
Kyung-Hyun Do
JLJune-Goo Lee
June-Goo Lee
WBWoong Bae
Woong Bae
JSJoon Beom Seo
Joon Beom Seo
Park S, et al. Korean J Radiol. 2019 Aug;20:e68. https://doi.org/10.3348/kjr.2019.0212

1 February 2021 in Clinical Cancer Research
Verified
Journal Article
Open access
PDF file
JPJeonghyuk Park
Jeonghyuk Park
BJBo Gun Jang
Bo Gun Jang
YKYeong Won Kim
Yeong Won Kim
HPHyunho Park
Hyunho Park
BKBaek-Hui Kim
Baek-Hui Kim
DKDong-Il Kim
Dong-Il Kim
Purpose: Gastric cancer remains the leading cause of cancer-related deaths in Northeast Asia. Population-based endoscopic screenings in the region have yielded successful results in early detection of gastric tumors. Endoscopic screening rates are continuously increasing, and there is a need for an automatic computerized diagnostic system to reduce the diagnostic burden. In this study, we developed an algorithm to classify gastric epithelial tumors automatically and assessed its performance in a large series of gastric biopsies and its benefits as an assistance tool. Experimental Design: Using 2,434 whole-slide images, we developed an algorithm based on convolutional neural networks to classify a gastric biopsy image into one of three categories: negative for dysplasia (NFD), tubular adenoma, or carcinoma. The performance of the algorithm was evaluated by using 7,440 biopsy specimens collected prospectively. The impact of algorithm-assisted diagnosis was assessed by six pathologists using 150 gastric biopsy cases. Results: Diagnostic performance evaluated by the AUROC curve in the prospective study was 0.9790 for two-tier classification: negative (NFD) versus positive (all cases except NFD). When limited to epithelial tumors, the sensitivity and specificity were 1.000 and 0.9749. Algorithm-assisted digital image viewer (DV) resulted in 47% reduction in review time per image compared with DV only and 58% decrease to microscopy. Conclusions: Our algorithm has demonstrated high accuracy in classifying epithelial tumors and its benefits as an assistance tool, which can serve as a potential screening aid system in diagnosing gastric biopsy specimens.

1 April 2021 in Radiology
Verified
Journal Article
Closed access
SPSohee Park
Sohee Park
SLSang Min Lee
Sang Min Lee
WKWooil Kim
Wooil Kim
HPHyunho Park
Hyunho Park
KJKyu-Hwan Jung
Kyu-Hwan Jung
JSJoon Beom Seo
Joon Beom Seo
Deep learning–based reduction in CT section thickness improved the sensitivity of computer-aided detection of subsolid nodules on thick-section images. Background Studies on the optimal CT section thickness for detecting subsolid nodules (SSNs) with computer-aided detection (CAD) are lacking. Purpose To assess the effect of CT section thickness on...

1 January 2023 in Journal of Cardiovascular Intervention
Verified
Journal Article
Open access
PDF file
BLByeong Tak Lee
Byeong Tak Lee
JKJoon-myoung Kwon
Joon-myoung Kwon
JCJinwoo Cho
Jinwoo Cho
WBWoong Bae
Woong Bae
HPHyunho Park
Hyunho Park
KJKi-Hyun Jeon
Ki-Hyun Jeon
Lee BT, et al. J Cardiovasc Interv. 2023 Mar;2:e13. https://doi.org/10.54912/jci.2022.0028

26 May 2025 in Health Insurance Review & Assessment Service Research
Verified
Journal Article
Open access
PDF file
HKHaedong Kim
Haedong Kim
HPHyunho Park
Hyunho Park
YKYeseung Kim
Yeseung Kim
JSJaeyong Shin
Jaeyong Shin
Haedong Kim, Hyunho Park, Yeseung Kim, Jaeyong Shin. HIRA Research 2025;5:67-75. https://doi.org/10.52937/hira.25.5.1.e4