Alessandro V. Matheoud

Alessandro V. Matheoud

Auto-generated profile, based on publicly available information

Alessandro V. Matheoud

Ecole Polytechnique Fédérale de Lausanne (EPFL) 2 , CH-1015 Lausanne, Switzerland

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2017 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
AMAlessandro V. Matheoud
Alessandro V. Matheoud
GGGabriele Gualco
Gabriele Gualco
MJminki jeong
minki jeong
IZIvica Zivkovic
Ivica Zivkovic
JBJürgen Brugger
Jürgen Brugger
GBGiovanni Boero
Giovanni Boero

3 June 2019 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
AMAlessandro V. Matheoud
Alessandro V. Matheoud
NSNergiz Sahin Solmaz
Nergiz Sahin Solmaz
GBGiovanni Boero
Giovanni Boero

1 March 2017 in Review of Scientific Instruments
Verified
Journal Article
Open access
MCMario A. Chavarria
Mario A. Chavarria
AMAlessandro V. Matheoud
Alessandro V. Matheoud
PMPhilippe Marmillod
Philippe Marmillod
YLYoujiang Liu
Youjiang Liu
DKDeyi Kong
Deyi Kong
GBGiovanni Boero
Giovanni Boero
A high sensitivity field asymmetric ion mobility spectrometer (FAIMS) was designed, fabricated, and tested. The main components of the system are a 10.6 eV UV photoionization source, an ion filter driven by a high voltage/high frequency n-MOS inverter circuit, and a low noise ion detector. The ion filter electronics are capable to generate square waveforms with peak-to-peak voltages up to 1000 V at frequencies up to 1 MHz with adjustable duty cycles. The ion detector current amplifier has a gain up to 1012 V/A with an effective equivalent input noise level down to about 1 fA/Hz1/2 during operation with the ion filter at the maximum voltage and frequency. The FAIMS system was characterized by detecting different standard chemical compounds. Additionally, we investigated the use of a synchronous modulation/demodulation technique to improve the signal-to-noise ratio in FAIMS measurements. In particular, we implemented the modulation of the compensation voltage with the synchronous demodulation of the ion current. The analysis of the measurements at low concentration levels led to an extrapolated limit of detection for acetone of 10 ppt with an averaging time of 1 s.

1 October 2020 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
ABAnthony Beaumont
Anthony Beaumont
DGDavid Giloteaux
David Giloteaux
AMAlessandro V. Matheoud
Alessandro V. Matheoud
MBMarco Buzio
Marco Buzio
GBGiovanni Boero
Giovanni Boero
We report on four electron paramagnetic resonance sensors for dynamic magnetic field measurements at 36 mT, 100 mT, 360 mT, and 710 mT. The sensors are based on grounded co-planar microwave resonators operating at about 1 GHz and 3 GHz, realized using printed circuit board technology, and on single-chip integrated microwave oscillators operating at about 10 GHz and 20 GHz, realized using complementary metal-oxide-semiconductor technology. The sensors are designed to mark precisely the moment when a time-dependent magnetic field attains a specific value. The trigger from the sensor can be used to preset the output of real-time magnetic field measurement systems, called “B-trains,” which are in operation at several large synchrotron installations, including five of the CERN’s particle accelerators. We discuss in detail the performance achieved, in particular, the magnetic field resolution that is in the range of 0.1 nT/Hz1/2–6 nT/Hz1/2. The effects of material anisotropy and temperature are also discussed. Finally, we present a detailed characterization of the sensors with field ramps as fast as 5 T/s and field gradients as strong as 12 T/m.