Artem R. Vinogradov

Artem R. Vinogradov

Auto-generated profile, based on publicly available information

Artem R. Vinogradov

S. Fyodorov Eye Microsurgery Federal State Institution

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 April 2026 in Journal of Volgograd State Medical University
Verified
Journal Article
Open access
PDF file
AVArtem R. Vinogradov
Artem R. Vinogradov
ALArseniy S. Lomakin
Arseniy S. Lomakin
SBSergey V. Balalin
Sergey V. Balalin
OYOleg V. Yuferov
Oleg V. Yuferov
AZAlexander V. Zubkov
Alexander V. Zubkov
One of the tasks in modern cataract surgery is the precise calculation of the intraocular lens power to achieve target refraction in the postoperative period. The purpose of the study. Conduct a comparative analysis of the clinical and functional outcomes of surgical treatment of uncomplicated cataract in patients from the control and main groups, determining the accuracy of IOL selection to achieve target refraction in the postoperative period with a deviation of no more than ±0.5 Dpt, as well as evaluating the criteria of efficacy, safety, predictability, and stability. Research methodology. A comparative analysis of the clinical and functional results of surgical treatment for uncomplicated cataracts was conducted on 1.038 patients (1.923 eyes) in the control group and 82 patients (146 eyes) in the main group, focusing on the accuracy of selecting intraocular lenses (IOLs) to achieve target refraction in the postoperative period with a possible deviation of no more than ±0.5 diopters. The results of the study. The use of an optimized technology for selecting the formula to calculate IOL power based on machine learning showed a significant advantage in the main group of patients. Six months after surgery, the uncorrected visual acuity in the main group was (0.80 ± 0.19) compared to (0.68 ± 0.23) in the control group (p 0.00001), and the best-corrected visual acuity was (0.83 ± 0.18) versus (0.74 ± 0.21) (p 0.00006). The achievement of target refraction in the postoperative period was significantly higher for patients whose calculations were made using the developed machine learning-based system, as confirmed by statistically significant lower values of subjective refraction and spherical equivalent refraction (p 0.05). The predictability of achieving target refraction within ±0.50 diopters using the machine learning system was 92.5 % compared to 76.1 % with the standard approach (p = 0.001), indicating a significant clinical advantage of the developed technology. Conclusion. The obtained clinical and functional results confirmed the applicability of the intelligent software system LensCalc as a decision-support tool for ophthalmologists. Achieving the target refraction in the postoperative period was significantly higher in patients whose calculations were performed using the developed machine learning-based system, as confirmed by statistically significant lower values of subjective refraction and spherical equivalent refraction (p 0.05).

30 June 2024 in Saratov Medical Journal
Verified
Journal Article
Closed access
AVArtem R. Vinogradov
Artem R. Vinogradov
SBSergei V. Balalin
Sergei V. Balalin
ESElena G. Solodkova
Elena G. Solodkova
Objective: to conduct a comparative analysis of the accuracy of intraocular lens (IOL) selection in patients with an eye length of less than 22.0 mm using the Barrett Universal II, Kane, and Hoffer Q formulas, as well as via artificial intelligence (AI). Materials and Methods. We analyzed the outcomes of 88 phacoemulsification cataract surgeries with monofocal IOL implantation. Preoperative biometry and IOL calculations were performed on an IOL Master 700 (Zeiss, Germany). The accuracy of IOL selection was also determined via the LensCalc software based on AI (DecisionTreeClassifier). Results. The axial length of the eyes in patients ranged from 19.8 to 22.0 mm. The prediction of achieving the target refraction was most accurate when using the Barrett Universal II formula rather than Hoffer Q (Z=2.12; p=0.034). The mean error in achieving the target refraction when using the Barrett Universal II formula did not differ from the Kane formula (p>0.05). Using AI, we established that higher accuracy in the IOL power calculation was achieved when using the Barrett Universal II formula. Conclusion. Based on a comparative analysis of the study results and an assessment of the accuracy of IOL selection using AI, we established that the Barrett Universal II formula (4th generation) was more accurate in determining the optical power of the IOL in short eyes than the Hoffer Q formula (3rd generation). Our calculation results based on using the Barrett Universal II formula, unlike the Hoffer Q formula, were similar (p>0.05) to those calculated using the Kane formula (5th generation), which, according to the results of the majority of published studies, is currently the most accurate formula for IOL selection.

30 June 2024 in Saratov Journal of Medical Scientific Research
Verified
Journal Article
Closed access
AVArtem R. Vinogradov
Artem R. Vinogradov
SBSergei V. Balalin
Sergei V. Balalin
ESElena G. Solodkova
Elena G. Solodkova
Objective: to carry out a comparative analysis of IOL fitting accuracy in patients with eye length less than 22.0 mm using Barrett Universal II, Kane, Hoffer Q and artificial intelligence formulas. Material and methods. The results of 88 phacoemulsification cataract operations with implantation of monofocal lOLs were analyzed. Preoperative biometry and IOL calculations were performed on the IOL Master 700. The accuracy of IOL fitting was also determined using the LensCalc program, which is based on artificial intelligence (DecisionTreeClassifier). Results. The eye length of the patients ranged from 19.8 to 22 mm. The prediction of the target refraction hit was the most accurate when using Barrett Universal II formulas as opposed to Hoffer Q (Z=2.12; p=0.034). The mean value of the target refraction hit error was not different when using the Barrett Universal II formula compared to the Kane formula (p>0.05). Using artificial intelligence it was found that higher accuracy in the results of IOL optical power determination was achieved when using the Barrett Universal II formula. Conclusion. Based on a comparative analysis of the study results and assessment of IOL fitting accuracy using artificial intelligence, it was found that the Barrett Universal II formula (4th generation) is more accurate in determining the optical power of lOLs in "short" eyes than the Hoffer Q formula (3rd generation). The results obtained using the Barrett Universal II formula, in contrast to the Hoffer Q formula, do not differ from the data calculated using the Kane formula (5th generation), which, according to the results of most studies, is the most accurate IOL selection formula at present (p>0.05).