Stefano Loreti

Stefano Loreti

Auto-generated profile, based on publicly available information

Stefano Loreti

Culham Science Centre

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Fusion Engineering and Design
Verified
Journal Article
Closed access
CNC.R. Nobs
C.R. Nobs
LPL.W. Packer
L.W. Packer
PBP. Batistoni
P. Batistoni
BCB. Colling
B. Colling
ZGZ. Ghani
Z. Ghani
TVT. Vasilopoulou
T. Vasilopoulou

1 April 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
GCGianluca Cavoto
Gianluca Cavoto
IAI. Abritta
I. Abritta
EBElisabetta Baracchini
Elisabetta Baracchini
Maurizio AngeloneMaurizio Angelone
Maurizio Angelone
Fabio BelliniFabio Bellini
Fabio Bellini
CVCecilia Voena
Cecilia Voena


31 March 2026 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Open access
MKMatteo Hakeem Kushoro
Matteo Hakeem Kushoro
GCGabriele Croci
Gabriele Croci
EGErik Gallo
Erik Gallo
Francesco La ViaFrancesco La Via
Francesco La Via
SLStefano Loreti
Stefano Loreti
Massimo NocenteMassimo Nocente
Massimo Nocente
Silicon carbide (SiC) detectors are promising candidates for neutron diagnostics in fusion environments, where instruments must endure intense neutron and gamma fluxes, high temperatures, and restricted accessibility. Partial depletion operation enables online control of detector efficiency by varying the applied bias voltage, thereby tuning the response to adapt to the widely changing neutron fluxes expected in future tokamak experiments. In this work, the functionality of two 4H-SiC detectors with different thicknesses (100 μm and 250 μm) is investigated under partial depletion conditions. Measurements are performed with 2.5 MeV and 14 MeV neutrons produced at the Frascati Neutron Generator and benchmarked against Geant4 simulations. Results show that detector efficiency can be predictably controlled within a factor of five without degrading energy resolution. Full depletion in the 100 μm device was reached at lower voltages than expected, possibly due to doping variations or irradiation effects. These findings confirm the potential of partial depletion as a tool for real-time tuning of SiC detector response, with significant implications for neutron diagnostics in future fusion reactors.

22 February 2021 in EPJ Web of Conferences
Verified
Journal Article
Open access
PDF file
LPL W Packer
L W Packer
Maurizio AngeloneMaurizio Angelone
Maurizio Angelone
MGMark R. Gilbert
Mark R. Gilbert
SLS Loreti
S Loreti
CNC R Nobs
C R Nobs
OVO Vilkhivskaya
O Vilkhivskaya
We compare existing experimental decay heat data sets measured at the JAEA fusion neutron source (FNS), which employed a fast extraction rabbit system that in certain cases allowed the measurements to capture, at short cooling times, the decay profile of 16N in a range of oxides. Focussing on those data points and timescales that can be attributed to 16N, we compare measurements to simulations performed using the FISPACT-II inventory code together with evaluated nuclear data libraries. Making small corrections for other contributions at these short times, we derive integral cross section data estimates for 16O(n,p)16N from 12 oxide sample measurements and compare with previously obtained measurements in the IAEA EXFOR database and evaluations in the nuclear data libraries themselves.

1 October 2026 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Open access
NFN Fonnesu
N Fonnesu
SLS Loreti
S Loreti
RVR Villari
R Villari
DFDavide Flammini
Davide Flammini
ACAndrea Colangeli
Andrea Colangeli
JCJet Contributors
Jet Contributors
Within the framework of EUROfusion’s technological exploitation of deuterium–tritium (DT) operation at JET—initiated under work package JET3 and continued under PrIO—the NEXP sub-project was conceived to exploit the substantial neutron yield expected during the DT campaigns (DTE2 and DTE3) to validate the numerical tools employed for neutron streaming and shutdown dose rate (SDDR) prediction in ITER. This validation, grounded in direct comparison between computational predictions and experimental measurements, constitutes a critical step in demonstrating the reliability of the SDDR methodology that underpins ITER’s radiation safety case. As part of this activity, a dedicated dosimetry system based on spherical air-vented ionization chambers was installed in the JET Torus Hall in 2015 and has since undergone successive hardware and software upgrades to address operational challenges identified across DT experimental campaigns. This work traces the evolution of the SDDR dosimetry system and presents the analysis of the measurements acquired during the DT operation of JET, in particular the third DT campaign (DTE3) and, uniquely, throughout the ongoing final shutdown, a phase offering measurement conditions unlikely to be replicated elsewhere. SDDR predictions with the Advanced D1S tool by ENEA are described as well.