In this paper, we proposed a novel method to determine the oil film thickness on water with a wide range, which is based on the intensity ratio between the laser-induced oil film fluorescence and Raman scattering of the water without oil films. To verify the feasibility of this method, we presented a portable detection system which employs a laser diode at 405 nm and an intensified charged-coupled device (ICCD) detector. Using this system, the diesel oil films with variable thicknesses on water were measured at different distances. The measured thickness was in the range from 0.07 mm to 36.62 mm with an average relative error of 5.98% and 4.07% by parameter calibration method (PCM) and spectral fitting method (SFM), respectively. The experimental results showed that the effective thickness range measured using the proposed ratio method is 40 times greater than that measured by the traditional Raman suppression method (less than 0.82 mm). In addition, different thicknesses of crude oil films were also measured, and the effective thickness range was from 0.002 mm to 0.493 mm, which was 70 times greater than the traditional Raman method (less than 0.007 mm). In the range of 0.007 mm to 0.493 mm, the average relative error is less than 10% using the proposed ratio method. Furthermore, this method can greatly eliminate the influences from the detection distances, instrument factors and external environments compared with the fluorometric method.
In order to realize rapid and accurate evaluation of drinking water quality, a small-scale water quality detection instrument is designed in this paper that can detect two representative water quality parameters: the permanganate index and total dissolved solids (TDS). The permanganate index measured by the laser spectroscopy method can achieve the approximate value of the organic matter in water, and the TDS measured by the conductivity method can obtain the approximate value of the inorganic matter in water. In addition, to facilitate the popularization of civilian applications, the evaluation method of water quality based on the percent-scores proposed by us is presented in this paper. The water quality results can be displayed on the instrument screen. In the experiment, we measured the water quality parameters of the tap water as well as those after the primary and secondary filtration in Weihai City, Shandong Province, China. The testing results show that the instrument can quickly detect dissolved inorganic and organic matter, and intuitively display the water quality evaluation score on the screen. The instrument designed in this paper has the advantages of high sensitivity, high integration, and small volume, which lays the foundation for the popularity of the detection instrument.
To enhance sensitivity in detecting phosphorus in water via laser-induced breakdown spectroscopy (LIBS), this study integrates liquid–solid conversion on graphite substrates with a PLS-SVR fusion algorithm. Optimized laser parameters (500 mJ, 13 pulses) improved plasma excitation and signal-to-noise ratios. The graphite substrate adsorbed phosphorus, converting liquid samples into a solid matrix to suppress matrix interference and intensify spectral lines (P I 213.6 nm and 214.9 nm), achieving detection limits of 0.09 mg/L and 0.23 mg/L, respectively. Calibration curves showed high accuracy (R2 = 0.9936). In real-world testing, absolute errors were below 0.017 mg/L, with relative errors <12%, aligning closely with traditional ammonium molybdate spectrophotometry. The PLS-SVR algorithm boosted prediction accuracy through data enhancement and spectral feature extraction, reducing errors to 2.1% (0.625 mg/L) and 5.6% (2.5 mg/L). With rapid sample preparation (<10 min), this method offers an efficient, low-cost solution for in situ phosphorus monitoring, advancing LIBS from lab to field use and supporting precise eutrophication management.
Chemical Oxygen Demand (COD) serves as a crucial metric for assessing the extent of water pollution attributable to organic substances. This study introduces an innovative approach for the detection of low-concentration COD in aqueous environments through the application of Laser-Induced Fluorescence (LIF) image processing. The technique employs an image sensor to capture fluorescence image data generated by organic compounds in water when excited by ultraviolet laser radiation. Subsequently, the COD value, indicative of the concentration of organic matter in the water, is derived via image processing techniques. Utilizing this methodology, an LIF image processing COD detection system has been developed. The system is primarily composed of a CMOS image sensor, an STM32 microprocessor, a laser emission module, and a display module. In this study, the system was employed to detect mixed solutions of sodium humate and glucose at varying concentrations, resulting in the acquisition of corresponding fluorescence images. By isolating color channels and processing the image data features, variations in RGB color characteristics were analyzed. The Partial Least Squares Regression (PLSR) analysis method was utilized to develop a predictive model for COD concentration values based on the average RGB color feature values from the characteristic regions of the fluorescence images. Within the COD concentration range of 0–12 mg/L, the system demonstrated a detection relative error of less than 10%. In summary, the system designed in this research, utilizing the LIF image processing method, exhibits high sensitivity, robust stability, miniaturization, and non-contact detection capabilities for low-concentration COD measurement. It is well-suited for rapid, real-time online water quality monitoring.
16 January 2024 in IEEE Transactions on Instrumentation and Measurement
In this article, a field-portable water quality detection instrument for noncontact chemical oxygen demand (COD) measurement was presented based on laser spectroscopy. In this instrument, a semi-conductor laser at 405 nm was selected as the excitation source. The COD value can be obtained by analyzing the received spectrum based on the fluorescence integral-Raman ratio (FIRR) method when the laser emits into water at a certain distance. For facilitating COD measurements in a laboratory, the sodium humate and glucose mixed solution at a certain proportion were chosen to simulate natural water. The maximum relative error of COD value measured by our designed instrument at the distance 1–10 m is 7.44% with the laser output power of 50 mw. At the output laser range of 10–100 mw and the distance of 5 m, the maximum relative error is 7.96%. In addition, using the instrument, we measured the field water in Weihai city, China, and the COD results are consistent with those tested by laboratory chemical method. In the experimental process, the instrument was less influenced by the variation of detection distance, laser output power and testing environment. It has advantages of high stability and anti-interference ability, which can be applied in noncontact COD measurement for many water areas.